517762
17
LED Cnt:
This is a measure of the infra-red light intensity required to sense the drum position. It
is normally about 14 but can range from 5 to 53.
Warning Status Screen
The last User Warning will be displayed on this
screen and will be displayed until another User
Warning overwrites it.
7.2.1
Testing the Conductivity Contacts
It is possible to check the integrity of the conductivity contacts through diagnostics. The same
method is used as for the Intuitive model. Refer to Section 7.1.3.
7.2.2
Data Download Mode
Encoded data is transmitted out of the
Wrinkle Free
LED, and can be captured by an optical
download pen attached to a PC or hand held palm PC, where “Smart Tool” software interprets the
data to aid servicing.
To enter the Data Download mode;
Enter diagnostic mode as described in Section 7.2, then press the
Start/Pause
button. The
Wrinkle Free
LED will flash. Place the data download pen over the LED to download the data.
To exit from the data download mode, press the
Power
button.
7.3
Entering the Diagnostic Mode – AeroSmart LED Model
To enter the
Diagnostic Mode
press and hold the
Wrinkle Free
button (button A) and then the
Power
button (button B). The dryer is now in
Diagnostic Mode
.
Press the
Time Dry
button (button C) three times to enter the last fault option.
Each LED has a specific value as follows:
LED
Sheets
Air Dry
Bulky
Easy Iron Wrinkle Free
Value
16 8 4 2 1
Example:
In this example, the LEDs with values “8”, “2” and “1” are on, therefore 8+2+1=11. Therefore fault
code #11 is displayed. Refer to Section 6.2 for fault codes.