517762
13
Fault Code 45 Display Module ROM Check Error
On power up, the display has checked its memory against a known reference and found
differences.
Remedy: Replace display module.
Fault Code 105 Comms Error Time Out
Communications failure between the sensor module and display module.
Remedy: (1) Visually check the contacts on the RAST (edge) connector at each end on
the harness between the sensor module and display module.
(2) Using a multimeter check for continuity of the wires on this harness.
(3) Replace display module.
(4) Replace sensor module.
Note:
On the LCD model, the green Air Dry LED illuminated without the fault “beeps”
indicates the dryer is in a low mains voltage (brown out) state, and may be
momentarily displayed when the supply power is turned off.
On the LED model, the Wrinkle Free LED illuminated without the fault “beeps”
indicates the dryer is in a low mains voltage (brown out) state, and may be
momentarily displayed when the supply power is turned off.
Содержание Intuitive DE62T27GW
Страница 1: ...517762 Electronic Models DEIX2 DGIX2 DE62T27GW DG62T27GW Supplementary to Issue B March 2005 517760B ...
Страница 2: ...517762 2 ...
Страница 22: ...517762 22 13 WIRING DIAGRAM ELECTRIC ...
Страница 23: ...517762 23 14 WIRING DIAGRAM GAS ...
Страница 24: ...517762 24 ...
Страница 25: ...517762 25 NOTES ...