5
Installation instructions
Rear venting installation
1
Establish the desired height of the
rangehood above the cooking surface
according to the ‘Installation height
requirements’ on page 4. Measure this
distance from the top of the cooking
surface and, using a spirit level, draw a
light horizontal line on the wall. Make sure
that the line can easily be erased or will be
hidden after installation. This is where the
bottom of the rangehood will sit (fig.1).
2
Mark the position of the rangehood on
the wall. Using a spirit level, also mark a
vertical line intersecting the horizontal
line, (ensuring that the line can easily be
erased or will be hidden after installation)
showing the position where the centre of
the rangehood will be. This is normally over
the centre of the cooktop (fig.2).
3
Remove the grease filters (this is to make
installation easier). Press inward on the
catch, found on the handle, and pull the
filter downward (fig.3).
4
Determine the position of the 133 mm
diameter cutout required for rear external
ducting out through the wall. From the
point where the horizontal and vertical lines
drawn earlier intercept, use a spirit level
and pencil to mark the centre point of the
cutout hole required 70 mm above the first
horizontal as shown in fig.4.
Fig.1 Establishing height of rangehood
60 – 75 cm
Fig.2 Marking the position of the rangehood on the wall
Benchtop
Bottom of rangehood
Rangehood centre
Fig.3 Removing the grease filters
Fig.4 Measuring the cutout for air outlet diameter
70 mm