Fisher & Paykel HF60CSW2 Скачать руководство пользователя страница 4

2

Important!

Please read the entire set of instructions before installing the rangehood.

This appliance is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a person responsible for their safety.

There must be adequate ventilation of the room when the rangehood is used at the same time 
as appliances burning gas or other fuels. (A partial vacuum in the room could result in too high a 
concentration of gas in the air).

You must read the details concerning the method and frequency of cleaning.

There is a fire risk if cleaning is not carried out in accordance with the instructions.

Do not flambé under the rangehood.

Exhaust air must not be discharged into an existing flue that is used for exhausting fumes from 
appliances burning gas or other fuels.

The minimum distance between the cooktop surface and the filters of the rangehood shall be  
600 mm, or 650 mm if installed over a gas cooktop.

Attention should be given to ensure that any applicable regulations concerning the discharge of 
exhaust air is fulfilled.

If the supply cord of this equipment is damaged it must only be replaced by the manufacturer, its 
service agent or similarly qualified person in order to avoid a hazard.

Always switch the power off prior to installation, servicing or cleaning the rangehood.

Never use the rangehood without the filters in place.

A power outlet should be within 750 mm of the motor assembly and can be either on the wall, 
behind the chimney or in the ceiling.

To comply with electrical safety regulations, this canopy must be plugged into a socket near the 
appliance. The socket must be accessible, or have an accessible isolating switch, to enable the end 
user to isolate the canopy from the power for the purpose of internal cleaning or maintenance.

Ducting accessories are not supplied. All ducting must comply with local requirements and 
building codes.

 WARNING!

Electrical Shock Hazard

All electrical work must be done in accordance with local and/or national 
electrical codes as applicable. For safety, this product must be earthed. If 
you are unfamiliar with methods of installing electrical wiring, employ the 
services of a qualified electrician. Turn off power at service entrance before 
installing wiring or servicing this product.

 WARNING!

5.5 kg

5.5 kg

Weight Hazard

The rangehood is heavy. Please ensure adequate care is taken when installing 
the rangehood to prevent personal injury. The rangehood must be installed 
onto a solid wall, stud, beam or truss. Weight of the product is 5.5 kg.

Safety and warnings

Содержание HF60CSW2

Страница 1: ...NZ AU Installation instructions and User guide Freestanding canopy HF60CSW2 HF60CSX2 models ...

Страница 2: ......

Страница 3: ...are 13 Important SAVETHESEINSTRUCTIONS The models shown in this User Guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please visit our local website listed on the back cover or contact your local Fisher Paykel dealer ...

Страница 4: ...ed it must only be replaced by the manufacturer its service agent or similarly qualified person in order to avoid a hazard Always switch the power off prior to installation servicing or cleaning the rangehood Never use the rangehood without the filters in place A power outlet should be within 750 mm of the motor assembly and can be either on the wall behind the chimney or in the ceiling To comply ...

Страница 5: ... 791779 Height of rangehood Where an electric cooktop is installed beneath the canopy the distance between the top of the cooktop and the underside of the rangehood must be a minimum of 600 mm and a maximum of 750 mm Where a gas fuelled cooktop is installed beneath the canopy the distance between the top of the pot rests and the underside of the rangehood must be a minimum of 650 mm and a maximum ...

Страница 6: ...th walled ducting which helps to reduce noise and increase airflow The use of flexible ducting is not recommended If there is no other option available the flexible ducting must be pulled as tight as possible All ducting must comply with local requirements and building codes Note we recommend an Easy Fit by Fisher Paykel or a UNIDUCT ducting system products that have been designed to expel air eff...

Страница 7: ...fter installation showing the position where the centre of the rangehood will be This is normally over the centre of the cooktop fig 2 3 Remove the grease filters this is to make installation easier Press inward on the catch found on the handle and pull the filter downward fig 3 4 Determine the position of the 133 mm diameter cutout required for rear external ducting out through the wall From the ...

Страница 8: ...angehood should now be able to be hung on these bolts screws through the two keyholes in the hood 7 Create additional means of attachment Keyholes alone are insufficient means of attachment There are two extra holes found on each side of the back panel Select one on each side and fit screws with an anchor if required to ensure proper attachment as shown in fig 6 Ensure all fixings are secure 8 If ...

Страница 9: ... the air back into the kitchen via the front air vent 4 Fit the charcoal filter onto the clips located in the centre of the motor casing grill fig 10 5 Turn the charcoal filter to clockwise to lock the filter into position on the clips 6 The hood is now set to recirculation mode The charcoal filter is a disposable item and it is recommended to replace every 3 6 months depending on use Fig 12 Hook ...

Страница 10: ... the back edge of the hood will sit measure and mark where to drill 6 Drill 6 mm diameter holes and secure the rangehood to the cabinetry using the small wood screws supplied The rangehood should now be able to be hung on these screws through the four keyholes in the hood 7 Create additional means of attachment Keyholes alone are insufficient means of attachment There are extra holes found on top ...

Страница 11: ...9 Control panel Fig 16 Slide control Fan Off Fan On Low Fan On Medium Fan On High Lights On Lights Off Getting started quickly ...

Страница 12: ...n of the frame may occur Charcoal filters Charcoal filters are designed to remove grease and odours from cooking vapours prior to the cleansed air re entering the kitchen when the rangehood is in recirculating mode Charcoal filters are disposable items and it is recommended that these should be replaced every three to six months depending on use Note Fully saturated charcoal filters can become a b...

Страница 13: ...domestic use or 2 Use in accordance with the Product s User Guide C Defects to the Product caused by accident neglect misuse or Act of God D The cost of repairs carried out by non authorised repairers or the cost of correcting such unauthorised repairs E Normal recommended maintenance as set out in the Product s User Guide F Repairs when the appliance has been dismantled repaired or serviced by ot...

Страница 14: ...nicians can carry out any service necessary on your appliance Your dealer or our Customer Care Centre can recommend a Fisher Paykel Authorised Repairer in your area In Australia if you need assistance Call the Fisher Paykel Customer Care Centre and talk to one of our Customer Care Consultants Toll Free 1 300 650 590 Fax 07 3826 9298 Email customer care fp com au Postal Address PO Box 798 Cleveland...

Страница 15: ......

Страница 16: ...he product specifications in this booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available ...

Отзывы: