DIAGNOSTIC MODE cont:
The following tests can be carried out in the diagnostic mode.
3.2 LID SWITCH & OUT OF BALANCE SWITCH TEST
Press the
SPIN SPEED UP
button until the
MEDIUM SPIN
LED is on, (binary count 4).
When the Lid is open the 12 minute wash LED will be on.
Activating the Out of Balance lever under the top deck will cause the 6 minute LED to turn on. The
Out of Balance lever can be activated by moving the inner basket towards the right hand corner of
the cabinet. It will take up to 1 second for the LED to respond after the Out of Balance has been
activated.
Also when in this mode with the
MEDIUM SPIN SPEED
LED on, the
SPIN LED
will display the
SIZE SETTING
.
SPIN LED on = MODEL GWL08
3.3 DRAIN PUMP TEST
The
REGULAR CYCLE
button turns the drain pump on or off. The
REGULAR LED
will turn
on when the pump is on. This feature can be used to drain the tub.
3.4 WATER VALVE TEST
Press the
WASH TEMPERATURE DOWN
button to turn the Cold Water Valve on. The Cold
Water LED will also turn on.
Press the
WASH TEMPERATURE UP
button to turn the Hot Valve on. The Hot Water LED will
also turn on.
NOTE:
The drain pump test, water valve test, restart and recycle features can be used on any level in the
diagnostic mode.