13
INSTALLATION INSTRUCTIONS
Adjusting the minimum burner setting
●
This has been adjusted at the factory for Natural Gas but may need adjusting for local
conditions.
●
When converting to LPG, the minimum setting MUST be re-adjusted for each burner.
●
To adjust the minimum setting, you will need a Ø 3 X 75mm screwdriver.
1
Light the burner and set the control dial to its minimum.
2
Remove the dial and the plastic cover over the valve.
3
Slowly turn the adjustment screw on the valve until a minimum regular flame is
achieved. Note:
●
The flame will diminish when the screw is turned clockwise, and increase when turned
anti-clockwise.
4
Refit the plastic cover and dial.
5
Check the minimum burner setting: quickly turn the dial from maximum to minimum.
The flame must not go out. If it does, repeat the steps above.
Repeat the steps above for each burner.