INSTALLATION INSTRUCTIONS
Converting to a different gas type
IMPORTANT!
Gas conversion may only be carried out by a suitably qualified person.
●
To convert from one gas type to another, you need to replace the injectors and adjust
the minimum burner setting.
●
To replace the injectors, you will need a 7mm box spanner. This is not supplied.
1
Switch the power supply to the cooktop off at at the wall.
IMPORTANT!
Disconnect cooktop from the power supply before continuing.
2
Make sure each control dial is turned to O (OFF).
3
Remove all the pan supports and burner heads.
4
Pull off the control dials.
5
Using a 7mm box spanner, remove the injectors and replace them with the correct ones
(size numbers are stamped on the inside, eg 70=0.70mm). Hold on to the card housing
the replacement injectors for later use.
6
Check insulation resistance and earth continuity.
7
Switch the power supply to the cooktop back on at the wall.
8
Refit the control dials.
9
Adjust the minimum burner setting.
See section ‘Adjusting the minimum burner setting’ following.
!0
Check that all burners have a good flame.
!1
To indicate the gas type change, peel the adhesive label off the replacement injector
card and stick it into the framed ‘gas type’ area on the appliance data label (on the
underside of the cooktop). A second conversion label should also be affixed to the
duplicate appliance data label.