background image

Max. distance of 
hoses and cord from 
chassis edge 

Left hand 

side

Right hand 

side

Drain hose

2000 mm

1800 mm

Inlet hose

1650 mm

1250 mm

Power cord 

(excl. plug)

1650 mm

1650 mm

Left hand 

side

Right hand 

side

(2,2)  -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM

(2,2)  -1- 599683B DD60S installA2 NZGB.indd 6/7/09 11:36:09 AM

Содержание DishDrawer DD60S Series

Страница 1: ...use caution could result in injury or cuts Importantsafetyinstructions Installation of this DishDrawer requires basic mechanical and electrical skills Be sure to leave these Instructions with the Customer Installation must comply with your local building and electricity regulations At the completion of the DishDrawer installation the Installer must perform the Final Checklist Remove all packaging ...

Страница 2: ... 398 398 min J height of venting area at base of product 7 9 9 K height of installation bracket slots ontopofchassis 2 2 2 Chassisheightsincludebracketslots Panelthickness 18mm Note for Prefinished Flat door models the height from the top of handle to the top of door 64 mm I Installation diagrams for illustration purposes only A B C Cabinetry dimensions mm Prefi nished LCD DD60S Prefi nished Flat ...

Страница 3: ... clearance services hole can be higher If hole is higher ensure drain hose is routed straight into the waste connection Water Connection Recommended COLD Maximum 60 C BSP GB20 to suit flat washer Water Pressure Max Min Water softener models 1 MPa 145 psi 0 1 MPa 14 5 psi Other models 1 MPa 145 psi 0 03 MPa 4 3 psi Drains will need to be separated to satisfy kosher requirements We suggest you confi...

Страница 4: ...side Right hand side Drain hose 2000 mm 1800 mm Inlet hose 1650 mm 1250 mm Power cord excl plug 1650 mm 1650 mm Left hand side Right hand side 2 2 1 599683B DD60S installA2 NZGB indd 6 7 09 11 36 09 AM 2 2 1 599683B DD60S installA2 NZGB indd 6 7 09 11 36 09 AM ...

Страница 5: ...s to secure the product Ensure the sound insulation is repositioned correctly B 2 30 mm 1 5 5 3 4 Ensure the drawer is removed and then rotated anti clockwise to prevent kinked hoses A 1 2 1 3 3 optional x2 Ensure hoses and cord are not kinked or twisted If top mounting brackets are being used ensure they re securely fitted before sliding product into cavity B A OR optional A A B B C C max 19 mm 1...

Страница 6: ...sted and the latches at the rear of each drawer runner are facing forward Ensure the drawer clips on both sides are reset Ensure the drawer is now rotated clockwise back A 1 2 2 599683B DD60S installA2 NZGB indd 6 7 09 11 36 30 AM 1 2 2 599683B DD60S installA2 NZGB indd 6 7 09 11 36 30 AM ...

Страница 7: ...ied drain hose joiner 19 mm waste tee HIGHLOOP min 150 mm Ensure hoses are routed straight to joiner Remove excess hose material if necessary DishDrawer and Standpipe Ø 38 mm Fit the supplied rubber washer Fit the supplied rubber washer B Waste Disposal optional Donotconnectto DishDrawer Waste Disposal optional Donotconnectto DishDrawer 750 882 5 mm min R 200 mm 2 1 2 599683B DD60S installA2 NZGB ...

Страница 8: ...inage connection for leakage Spray arm Excessive water remaining above the filter plate after the rinse cycle Check for kinked drain hoses or blocked waste connection highloop not properly installed or drain hoses not routed correctly No water supply shows on display models with LCD only Check water is connected turned on and the spray arm is correctly fitted and free to rotate No lights come on w...