background image

18

!6

 

FITTING A CUSTOM TOEKICK PANEL

PROFILE A

PROFILE B

9

Custom Toekick Panel

Toekick mounting bracket 
cutting template

Custom toekick panel

Toekick mounting bracket 
cutting template

Toekick mounting 
bracket

If you require a cutout in your custom 
toekick panel, choose the most 
appropriate cutout profile (

A

 or 

B

depending on the final depth of your 
toekick panel.

After marking the panel, carefully cut or 
router out the desired profile. Use the 
template as a cutting guide.

Place the Toekick mounting bracket cutting 
template onto your toekick panel. Ensure they 
are centered and the template rests on the 
top surface of the panel.

Secure template to panel either by clamping 
or using the supplied mounting screws.

1

4

4

5

6

1

2

2

3

3

IMPORTANT!

Do not overtighten screw.

IMPORTANT!

Ensure all bare edges are sealed appropriately.

Slide the toekick onto the mounting rails 
either side and screw the toekick onto 
the bottom of tub on either side.

Place the Toekick mounting bracket onto your 
toekick panel. Ensure they are centered and 
the top of the template aligns with the top 
surface of the panel.

Secure template to panel using the supplied 
toekick mounting screws.

5

6

7

7

Toekick Depth

For a Toekick Depth 

1 9/16” (40mm)

For a Toekick Depth 

1 9/16” - 3 7/16”

(40mm - 88mm)

For a Toekick Depth 

3 7/16” - 3 15/16”

(88mm - 100mm)

Depth is measured from FRONT of door 

panel (assuming thickness ~ 11/16” (18mm) 

to front face of custom toekick label

Toekick mounting bracket 

cutting template:

PROFILE A

Toekick mounting bracket 

cutting template:

PROFILE B

NO CUTOUT

1 9/16” (40mm)

1 9/16” - 3 7

/16”

(40mm - 88mm)

3 7/16” - 3 15

/16”

(88mm - 100mm)

CUSTOM TOEKICK PANEL

CUSTOM TOEKICK PANEL

CUSTOM TOEKICK PANEL

Содержание DishDrawer DD24DTI

Страница 1: ...591386 A 08 17 INSTALLATION GUIDE US CA DD24DI DD24DTI DD24DHTI models DOUBLE DISHDRAWERTM DISHWASHER...

Страница 2: ...result in electrical shock or death WARNING Cut Hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts IMPORTANT SAFETY INSTRUCTIONS Installation of this dishwash...

Страница 3: ...OPTIONAL Prefinished toekick 1 Rubber washer for inlet hose 1 comes already fitted Hexagonal socket for feet adjustment 2 long short Side mounting bracket kit A and B 2 OPTIONAL Edge Protector 1 If th...

Страница 4: ...ide the terminal block cover sideways to unlock and hinge open to access the terminal block 6 Unscrew the Live Neutral and Earth wires as shown 7 Unscrew the three screws on the base as shown and remo...

Страница 5: ...d through or under under housing ribs 9 Screw down the Live Neutral and Earth wires correctly 10 Push the plastic harness cover back over It should clip back into place 11 Fold down and slide back the...

Страница 6: ...lower drawer front panel 12 1 4 14 3 16 311 360 12 1 4 14 3 16 311 360 J Ventilation gap between drawer front panels 5 16 8 5 16 8 K Height of toekick customisable 2 1 4 4 5 8 58 118 2 1 4 4 5 8 58 1...

Страница 7: ...in 34 864 P Inside width of cavity 23 5 8 600 23 5 8 600 Q Inside depth of cavity min 22 1 16 560 min 22 1 16 560 R Recommended height of adjacent cabinet space 30 762 30 762 S Height of toekick space...

Страница 8: ...I DD24DHTI models min 28 1 4 717mm B min 30 762mm B DD24DI models DD24DTI DD24DHTI models WIDTH OF PANEL HEIGHT OF UPPER PANEL HEIGHT OF LOWER PANEL 15 11 16 17 3 8 398mm 442mm Note The upper panel ex...

Страница 9: ...NO CUTOUT HEIGHT OF TOEKICK PANEL D 1 9 16 40mm 1 9 16 3 7 16 40mm 88mm 3 7 16 3 15 16 88mm 100mm B D 0 0mm recommended min 2 1 4 58 min 1 2 12mm Upper Panel extension height from top of product to t...

Страница 10: ...120 VAC max 15 A max 1 1 2 38 mm max 17 11 16 450 mm min 7 7 8 200 mm Moisture protection tape must be applied Services hole Can be located either side of dishwasher preferably at the bottom of the ca...

Страница 11: ...HOSES CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hoses 78 1 2 2000mm Drain hoses 70 1 2 1800mm Inlet hose 64 3 4 1650mm Inlet hose 49 1250mm Power cord excl plug 29 1 2 750mm Power co...

Страница 12: ...flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and...

Страница 13: ...driver prise the gray rubber plug out of the trim moulding Replace the gray rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a smal...

Страница 14: ...OUGH HOSES PUSH INTO THE CAVITY 1 B REMOVE THE LOWER DRAWER When fitting brackets ensure the ends are not pushed down into the chassis 1 2 4 4 3 3 To prevent kinked hoses Either sit the drawer down on...

Страница 15: ...oduct is level and aligning with cabinetry Hexagonal socket The top mounting brackets will only bend upwards a maximum of 3 8 10 mm 4 B REFIT THE DRAWER ONTO THE RUNNERS 1 2 3 4 Before refitting the d...

Страница 16: ...y or re 3 1 1 5 B REMOVE BOTH PANEL BRACKETS FROM PRODUCT Remove side pins and gently pull off the panel bracket slightly Repeat for the other drawer Remove the Knock to Pause module from the back of...

Страница 17: ...off and discard the tab at the top of the Lower Panel Bracket 5 D ATTACH KNOCK TO PAUSE MODULES TO CUSTOM PANELS IMPORTANT Ensure the Knock To Pause module is orientated correctly before attaching Ens...

Страница 18: ...t extends past the rubber seal must be earthed too Failure to follow these warnings may result in electrical shock injury or re Reconnect the Earth Wire to the Panel bracket Repeat for the other drawe...

Страница 19: ...3 3 IMPORTANT Do not overtighten screw IMPORTANT Ensure all bare edges are sealed appropriately Slide the toekick onto the mounting rails either side and screw the toekick onto the bottom of tub on ei...

Страница 20: ...ub on either side Where the toekick meets the bottom of the tub is the cut off point Mark this point on the toekick with a pencil Lay the toekick face down on a chopping board or similiar Score along...

Страница 21: ...IMPORTANT Ensure that drain connection will comply with local plumbing regulations min R 8 200 mm 29 1 2 34 3 4 750 882 5 mm 1 1 2 38 mm 29 1 2 34 3 4 750 883 mm Screw Drain hose support to back wall...

Страница 22: ...comply with local plumbing regulations DRAINAGE OPTION 2 Dishwasher using Air Break with Drain Hose Joiner 37 3 8 950 mm Max height to top of Air Break countertop or wall mounted 1 2 step 18 Secure b...

Страница 23: ...883 mm step 18 Supplied drain hose joiner to suit 3 4 19 mm waste tee Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose 29 1...

Страница 24: ...ed on If it is and still no indicator ligths up see the Preference options section of the Quick start guide An option called Open drawer auto power on may need to be turned on Water around water suppl...

Страница 25: ...e securing the racks is removed from the drawers Water softener models only adjust the water softener setting from the default setting to suit the water hardness of the area See the Quick start guide...

Страница 26: ...591386 A 08 17 INSTALLATION GUIDE US CA DD24SI DD24STI DD24SHTI models SINGLE DISHDRAWERTM DISHWASHER...

Страница 27: ...result in electrical shock or death WARNING Cut Hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts IMPORTANT SAFETY INSTRUCTIONS Installation of this dishwash...

Страница 28: ...er washer for inlet hose 1 comes already fitted Side mounting bracket kit A and B 2 OPTIONAL Edge Protector 1 If the services hole is through a metal partition the hole must be protected with the Edge...

Страница 29: ...de the terminal block cover sideways to unlock and hinge open to access the terminal block 6 Unscrew the Live Neutral and Earth wires as shown 7 Unscrew the three screws on the base as shown and remov...

Страница 30: ...ed through or under under housing ribs 9 Screw down the Live Neutral and Earth wires correctly 10 Push the plastic harness cover back over It should clip back into place 11 Fold down and slide back th...

Страница 31: ...5 8 13 16 16 20 F Height of drawer front panel min 16 1 16 408 3 min 17 13 16 452 4 G Height of chassis 1 16 1 8 410 17 7 8 454 H Ventilation gap below drawer front panel min 1 6 2 min 1 6 2 I Maximum...

Страница 32: ...djacent cabinetry min 1 2 13 mm clearance from a corner cupboard Custom Filler Panel min 1 16 2 mm clearance to adjacent cupboard door PROFILE PROFILE Bracket slots PLAN If your cavity height leaves a...

Страница 33: ...p WIDTH OF PANEL HEIGHT OF PANEL Note when the top of the dishwasher has to be lower than the adjacent cabinetry the top of the panel can extend above the chassis where required however a min 1 16 2mm...

Страница 34: ...cabinetry must not extend above cavity base These marks indicate formed bracket screw locations if securing by drawer removal If there is no side partition you can construct timber bracing as somethi...

Страница 35: ...nsation from the vent hose a toekick height of no less than 4 100mm is required IMPORTANT To prevent pooling of condensation from the vent hose a toekick height of no less than 4 100mm is required 8 P...

Страница 36: ...27 1 2 700mm RIGHT HAND SIDE IMPORTANT The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after installation Ensure the cavity panel b...

Страница 37: ...itted before sliding product into cavity The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and B bracket must match B slot When fitting bracket...

Страница 38: ...the gray rubber plug back into the trim moulding and ensure the trim seal is facing forward Repeat for all four brackets Using a small Philips screwdriver screw through the trim moulding securing the...

Страница 39: ...ly attached to it As you push product in pull through hoses and cord ensuring they don t get kinked or twisted IMPORTANT If product cannot be pushed in far enough pull out again and rearrange hoses an...

Страница 40: ...back to release drawer from runners Lift drawer off runners Push drawer runners back in on either side Push drawer runners back in on either side Sit the drawer down Rotate the drawer clockwise max 90...

Страница 41: ...rawer runner are facing forward Lift or rotate counter clockwise the drawer back onto the drawer runners on either side Pull the release tabs forward on both sides 4 100mm Ensure the tabs are fully pu...

Страница 42: ...s warning may result in electrical shock injury or re 3 1 1 7 A REMOVE PANEL BRACKET FROM PRODUCT Remove side pins and gently pull off the panel bracket slightly Remove the Knock to Pause module from...

Страница 43: ...ith the bottom of each bracket 7 D ATTACH KNOCK TO PAUSE MODULE TO CUSTOM PANEL IMPORTANT Ensure the Knock To Pause module is orientated correctly before attaching Ensure the module is centralized in...

Страница 44: ...he rubber seal must be earthed too Failure to follow these warnings may result in electrical shock injury or re Reconnect the Ground Wire to the Panel bracket or 1 16 2mm Push the Custom Panel on to t...

Страница 45: ...e IMPORTANT Ensure that drain connection will comply with local plumbing regulations min R 8 200mm 29 1 2 34 3 4 750 882 5 mm 1 1 2 38 mm 29 1 2 34 3 4 750 883mm Screw Drain hose support to back wall...

Страница 46: ...on will comply with local plumbing regulations DRAINAGE OPTION 2 Dishwasher using Air Break with Drain Hose Joiner 37 3 8 950mm Max height to top of Air Break countertop or wall mounted step 19 Secure...

Страница 47: ...50 883mm step 19 Supplied drain hose joiner to suit 3 4 19 mm waste tee Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose 29 1...

Страница 48: ...22 Ensure the supplied rubber washer is fitted inside the coupling Tighten coupling with spanner 180o No leaks 1 2 9 CONNECT INLET HOSE TO HOT WATER 0 SWITCH PRODUCT ON...

Страница 49: ...r is opened Ensure power is connected and is switched on If it is and still no indicator ligths up see the Preference options section of the Quick start guide An option called Open drawer auto power o...

Страница 50: ...ny packaging or tape securing the racks is removed from the drawers Water softener models only adjust the water softener setting from the default setting to suit the water hardness of the area See the...

Страница 51: ...25...

Страница 52: ...26...

Отзывы: