11
LEAK TESTING
2
1
3
Remove the 2 screws securing
the valve panel to the unit using
a Phillips screwdriver.
Remove all dials by pulling outwards.
Pull the valve panel down then
outward and unplug any wires.
Removing the valve panel
Testing for leaks
1
2
Prepare soap solution by combining
one part liquid detergent and one
part water. Pour into a spray bottle.
Ensure all control valves are in the
OFF
position before turning the gas
supply
ON
.
Check all connections from the
supply line or LP cylinder by
applying the solution around the
connection, tubing and end of the
manifold. Soap bubbles will appear
where a leak is present.
A complete gas tightness check must be performed at the installation site. Periodically check
the whole system for leaks, or immediately if the smell of gas is present.
If a leak is present
Immediately turn the gas supply
OFF
and tighten any leaking connections. Turn gas
ON
,
and recheck. If you cannot stop a gas leak turn the gas supply
OFF
and call your local gas
utility or the dealer you purchased the appliance from. Only parts recommended by the
manufacturer should be used on the side burner/griddle, substitution can void the warranty.