![Fisher & Paykel DCS GDE1 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/fisher-and-paykel/dcs-gde1/dcs-gde1_installation-manual_2295725014.webp)
12
FLAME HEIGHT ADJUSTMENT
Flames should be blue and stable with no
yellow tips, excessive noise or lifting (Note:
LP units may have some yellow tipping). If
any of these conditions exist, check the air
shutter and burner ports are clear. If cleaning
these does not improve performance, the air
shutter can be adjusted.
1
3
2
Reinstall the U-burner and light
to check. If the flame is blue and
stable, remove the burner, tighten
the air shutter screw and replace all
parts. If flame is still unstable, repeat
the above steps.
Ensure the griddle is
OFF
and cool.
To access the air shutters, remove
the griddle plate. Refer to page 7
for guidance.
With a screw driver, loosen the lock
screw on the face of the air shutter
so it can be adjusted. If the flame is
yellow turn the air shutter counter-
clockwise, if the flame is noisy and
tends to lift turn the air shutter
clockwise.
yellow tips noisy/lifting blue + stable
AIR SHUTTER