background image

DATE: 

02.05.2018

IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').  
Read the installation guide for detailed information on installing the product.  
For full installation instructions and specifications visit fisherpaykel.com

CAVITY PREPARATION

36" Professional Gas Cooktop

Model no:

CPV2-366

Cavity Dimensions

mm

Overall height of cutout

203

Overall width of cutout

min 914

Overall depth of cutout for projecting control panel

Overall depth of cutout for flush control panel

max 

614

max 

678

Electrical and Gas Supply Cutout

mm

Depth of supply area from rear of cutout

152

Width of supply area from left side of cutout

305

Specifications

36" Models

Electrical

Supply

120 VAC, 60Hz

Max. Current Draw

15 amp

Service

15 amp circuit

Gas – Natural

Connection

1/2” NPT Minimum 5/8” dia. flex line

Supply Pressure

Supply Pressure: 6” to 9” W.C.

Gas – LP

Connection

1/2” NPT Minimum 5/8” dia. flex line

Supply Pressure*

11” to 14” W.C.

A regulator is required at the LP source to provide a maximum pressure  
of 14” W.C. to the cooktop regulator.

B

C

A

e

D

ELECTRICAL & GAS

SUPPLY CUTOUT

Содержание BGCV2-1236

Страница 1: ...PLANNING GUIDE 36 PROFESSIONAL COOKTOPS BACKGUARDS CPV2 364GD CPV2 366 BGCV2 1236 BGCV2 3036 BGCV2 3036H models ...

Страница 2: ...ons 6 18 Clearance Dimensions 7 19 Cavity Preparation 8 20 36 Professional Cooktop CPV2 366 Product Cavity Dimensions 9 21 Clearance Dimensions 10 22 Cavity Preparation 11 23 36 Professional Range Backguard BGCV2 1236 Product Dimensions 12 24 36 Professional Range Backguard BGCV2 3036 Product Dimensions 13 25 36 Professional Range Backguard BGCV2 3036H Product Dimensions 14 26 ...

Страница 3: ...IMPERIAL ...

Страница 4: ...sherpaykel com KEY DESIGN DECISIONS 36 Professional Gas Cooktop INSTALL TYPE 1 REAR SURFACE 2 BACKGUARD OPTIONS 3 WALL ISLAND COMBUSTIBLE NON COMBUSTIBLE NO BACKGUARD LOW BACKGUARD LOW SHELF BACKGUARD HIGH SHELF BACKGUARD BGCV2 3036 BGCV2 3036H BGRV2 1236 NO BACKGUARD MIN 6 CLEARANCE CUSTOM FABRICATED BACKGUARD Fabricated from non combustible materials only CUSTOM BACKGUARD MAX 15 16 MIN 30 Model ...

Страница 5: ...N 30 MAX 36 30 COMBUSTIBLE COMBUSTIBLE 30 MIN 36 23 Model no CPV2 364GD CPV2 366 Note CPV2 366 illustrated but all dimensions apply to the above models Specifications Ventilation Unit Wall Installation Wall Chimney Hood 23 Deep x Unit Width Blower 600 CFM Ventilation Unit Island Installation Island Chimney Hood 30 Deep x Unit Width Blower 600 CFM Ventilation Unit Wall and Island Installation Downd...

Страница 6: ...rtop datum to bottom of chassis 8 B Overall height of product bottom of chassis to top of grates 9 15 16 C Overall width of cooktop 35 7 8 D Overall depth of cooktop 28 1 8 E Height above countertop datum to top of grates 1 15 16 F Height from countertop datum to chassis top surface 3 8 G Height of chassis 8 3 8 H Depth from rear of chassis to cabinetry datum projecting 24 3 16 I Depth from rear o...

Страница 7: ...le covering for ventilation hood centered above the cooking surface non combustible surface centered above the cooking surface 54 36 30 E Maximum overall depth of overhead cabinetry 13 DATUM BOTTOM OF CHASSIS FRONT VIEW PROFILE VIEW DATUM TOP OF COUNTERTOP CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL PLAN VIEW MINIMUM CLEARANCE ...

Страница 8: ...anel Overall depth of cutout for flush control panel max 24 3 16 max 26 11 16 Electrical and Gas Supply Cutout in D Depth of supply area from rear of cutout 6 E Width of supply area from left side of cutout 12 Specifications 36 Models Electrical Supply 120 VAC 60Hz Max Current Draw 15 amp Service 15 amp circuit Gas Natural Connection 1 2 NPT Minimum 5 8 dia flex line Supply Pressure Supply Pressur...

Страница 9: ...top datum to bottom of chassis 8 B Overall height of product bottom of chassis to top of grates 9 15 16 C Overall width of cooktop 35 7 8 D Overall depth of cooktop 28 1 8 E Height above countertop datum to top of grates 1 15 16 F Height from countertop datum to chassis top surface 3 8 G Height of chassis 8 3 8 H Depth from rear of chassis to cabinetry datum projecting 24 3 16 I Depth from rear of...

Страница 10: ...e covering for ventilation hood centered above the cooking surface non combustible surface centered above the cooking surface 54 36 30 E Maximum overall depth of overhead cabinetry 13 DATUM BOTTOM OF CHASSIS FRONT VIEW PROFILE VIEW DATUM TOP OF COUNTERTOP CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL PLAN VIEW MINIMUM CLEARANCE C...

Страница 11: ...nel Overall depth of cutout for flush control panel max 24 3 16 max 26 11 16 Electrical and Gas Supply Cutout in D Depth of supply area from rear of cutout 6 E Width of supply area from left side of cutout 12 Specifications 36 Models Electrical Supply 120 VAC 60Hz Max Current Draw 15 amp Service 15 amp circuit Gas Natural Connection 1 2 NPT Minimum 5 8 dia flex line Supply Pressure Supply Pressure...

Страница 12: ... visit fisherpaykel com PRODUCT DIMENSIONS 36 Professional Gas Cooktop 0 5 10 20 inches 35 7 8 B 12 15 16 A FRONT VIEW PLAN VIEW PROFILE VIEW c DATUM BOTTOM OF PRODUCT DATUM BACK OF PRODUCT DATUM BACK OF PRODUCT BGCV2 1236 CPV2 366 NOT TO SCALE Model no BGCV2 1236 Product Dimensions in A Overall height of backguard 12 B Overall width of backguard 35 7 8 C Overall depth of backguard 15 16 INDICATES...

Страница 13: ...N VIEW PROFILE VIEW c DATUM BOTTOM OF PRODUCT DATUM BACK OF PRODUCT DATUM BACK OF PRODUCT d BGCV2 3036 CPV2 366 NOT TO SCALE Model no BGCV2 3036 Product Dimensions in A Overall height of backguard 30 B Overall width of backguard 35 7 8 C Overall depth of backguard and racks 9 3 4 D Depth of backguard 15 16 E Depth of racks 8 13 16 F Width of racks 34 1 16 G Distance from top of backguard to bottom...

Страница 14: ... A f e h g FRONT VIEW PLAN VIEW PROFILE VIEW c DATUM BOTTOM OF PRODUCT DATUM BACK OF PRODUCT DATUM BACK OF PRODUCT d BGCV2 3036H CPV2 366 NOT TO SCALE 15 16 Model no BGCV2 3036H Product Dimensions in A Overall height of backguard 30 B Overall width of backguard 35 7 8 C Overall depth of backguard and racks 10 D Depth of backguard 15 16 E Depth of racks 9 1 16 F Width of racks 33 15 16 G Distance f...

Страница 15: ...METRIC ...

Страница 16: ...rpaykel com INSTALL TYPE 1 REAR SURFACE 2 BACKGUARD OPTIONS 3 WALL ISLAND COMBUSTIBLE NON COMBUSTIBLE NO BACKGUARD LOW BACKGUARD LOW SHELF BACKGUARD HIGH SHELF BACKGUARD BGCV2 3036 BGCV2 3036H BGRV2 1236 NO BACKGUARD CUSTOM FABRICATED BACKGUARD Fabricated from non combustible materials only CUSTOM BACKGUARD Model no CPV2 364GD CPV2 366 KEY DESIGN DECISIONS 36 Professional Gas Cooktop MIN 152mm CLE...

Страница 17: ...914mm MIN 762mm MAX 914mm 762mm 762mm MIN 914mm 584mm MIN 914mm Model no CPV2 364GD CPV2 366 Note CPV2 366 illustrated but all dimensions apply to the above models Specifications Ventilation Unit Wall Installation Wall Chimney Hood 584mm Deep x Unit Width Blower 600 CFM Ventilation Unit Island Installation Island Chimney Hood 762mm Deep x Unit Width Blower 600 CFM Ventilation Unit Wall and Island ...

Страница 18: ...mm A Height below countertop datum to bottom of chassis 203 B Overall height of product bottom of chassis to top of grates 253 C Overall width of cooktop 911 D Overall depth of cooktop 714 E Height above countertop datum to top of grates 50 F Height from countertop datum to chassis top surface 10 G Height of chassis 213 H Depth from rear of chassis to cabinetry datum projecting 614 I Depth from re...

Страница 19: ...ering for ventilation hood centered above the cooking surface non combustible surface centered above the cooking surface 1372 914 762 E Maximum overall depth of overhead cabinetry 330 DATUM BOTTOM OF CHASSIS FRONT VIEW PROFILE VIEW DATUM TOP OF COUNTERTOP CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL PLAN VIEW MINIMUM CLEARANCE C...

Страница 20: ...ol panel Overall depth of cutout for flush control panel max 614 max 678 Electrical and Gas Supply Cutout mm D Depth of supply area from rear of cutout 152 E Width of supply area from left side of cutout 305 Specifications 36 Models Electrical Supply 120 VAC 60Hz Max Current Draw 15 amp Service 15 amp circuit Gas Natural Connection 1 2 NPT Minimum 5 8 dia flex line Supply Pressure Supply Pressure ...

Страница 21: ...m A Height below countertop datum to bottom of chassis 203 B Overall height of product bottom of chassis to top of grates 253 C Overall width of cooktop 911 D Overall depth of cooktop 714 E Height above countertop datum to top of grates 50 F Height from countertop datum to chassis top surface 10 G Height of chassis 213 H Depth from rear of chassis to cabinetry datum projecting 614 I Depth from rea...

Страница 22: ...ring for ventilation hood centered above the cooking surface non combustible surface centered above the cooking surface 1372 914 762 E Maximum overall depth of overhead cabinetry 330 DATUM BOTTOM OF CHASSIS FRONT VIEW PROFILE VIEW DATUM TOP OF COUNTERTOP CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL PLAN VIEW MINIMUM CLEARANCE CO...

Страница 23: ...l panel Overall depth of cutout for flush control panel max 614 max 678 Electrical and Gas Supply Cutout mm D Depth of supply area from rear of cutout 152 E Width of supply area from left side of cutout 305 Specifications 36 Models Electrical Supply 120 VAC 60Hz Max Current Draw 15 amp Service 15 amp circuit Gas Natural Connection 1 2 NPT Minimum 5 8 dia flex line Supply Pressure Supply Pressure 6...

Страница 24: ...tions and specifications visit fisherpaykel com 0 100 200 400 millimetres 911 B 305 23 A FRONT VIEW PLAN VIEW PROFILE VIEW c DATUM BOTTOM OF PRODUCT DATUM BACK OF PRODUCT DATUM BACK OF PRODUCT BGCV2 1236 CPV2 366 NOT TO SCALE Model no BGCV2 1236 Product Dimensions mm A Overall height of backguard 305 B Overall width of backguard 911 C Overall depth of backguard 23 INDICATES PRODUCT DATUM ...

Страница 25: ...ONT VIEW PLAN VIEW PROFILE VIEW c DATUM BOTTOM OF PRODUCT DATUM BACK OF PRODUCT DATUM BACK OF PRODUCT d BGCV2 3036 CPV2 366 NOT TO SCALE Model no BGCV2 3036 Product Dimensions mm A Overall height of backguard 762 B Overall width of backguard 911 C Overall depth of backguard and racks 248 D Depth of backguard 23 E Depth of racks 224 F Width of racks 865 G Distance from top of backguard to bottom of...

Страница 26: ... B 911 B 762 23 A f e h g FRONT VIEW PLAN VIEW PROFILE VIEW c DATUM BOTTOM OF PRODUCT DATUM BACK OF PRODUCT DATUM BACK OF PRODUCT d BGCV2 3036H CPV2 366 NOT TO SCALE Model no BGCV2 3036H Product Dimensions mm A Overall height of backguard 762 B Overall width of backguard 911 C Overall depth of backguard and racks 254 D Depth of backguard 23 E Depth of racks 230 F Width of racks 862 G Distance from...

Страница 27: ...of issue Under our policy of continuous product improvement these dimensions and specifications may change at any time Dimensions may vary by 2mm 1 16 Please read the installation guide for detailed information on installing the product or visit fisherpaykel com May 2018 ...

Отзывы: