DATE:
02.05.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
INSTALL TYPE
1
WALL
ISLAND
HOOD SURROUND MATERIAL
2
NON COMBUSTIBLE
NON COMBUSTIBLE
COMBUSTIBLE
COMBUSTIBLE
VENTILATION REQUIREMENTS
36" Professional Gas Cooktop
584mm
MIN
762mm
MAX
914mm
MIN 762mm
MAX 914mm
762mm
762mm
MIN
914mm
584mm
MIN 914mm
Model no:
CPV2-364GD, CPV2-366
Note: CPV2-366 illustrated but all dimensions apply to the above models
Specifications
Ventilation Unit
Wall Installation
Wall Chimney Hood
584mm Deep x Unit Width
Blower
600 CFM
Ventilation Unit
Island Installation
Island Chimney Hood
762mm Deep x Unit Width
Blower
600 CFM
Ventilation Unit
Wall and Island Installation
Downdraft*
Unit Width
Blower
600 – 1200 CFM
Note: A suitable ventilation unit must be installed with the cooktop.
The above indicates the minimum blower capacity recommended for
ventilation units.
* Not illustrated.
Содержание BGCV2-1236
Страница 3: ...IMPERIAL ...
Страница 15: ...METRIC ...