517760C
20
11 COOL
DOWN
The dryer enters a cool down period at the end of the cycle. During this period the dryer continues
to run with the heating elements/burner turned off, blowing ambient air through the load to help
prevent creasing.
Autosensing:
If any AutoSensing cycle has been selected, the cool down period will continue until
the exhaust temperature drops to 95
o
F (35
o
C). However, if this temperature is not achieved after
10 minutes, the cycle will stop. This would occur if the ambient temperature was above 95
o
F
(35
o
C).
Timed Dry:
If an 80 minute or 40 minute Timed Dry cycle has been selected, the cool down period
will run for the last 10 minutes of that cycle. If a 20 minutes Timed Dry cycle has been selected,
the cool down period will run for the last 5 minutes.
Cycle
Cool Down
Autosensing
Cool down will last until the exhaust temperature drops to 95
o
F (35
o
C)
or 10 minutes, whichever occurs first.
Timed Dry 80 Minutes
10 Minutes
Timed Dry 40 Minutes
10 Minutes
Timed Dry 20 Minutes
5 Minutes