Installation instructions
33
Preferred 4” (102 mm) Hoods
4” Dia (102 mm)
4” (102 mm)
4” Dia (102 mm)
When you have a 4” (102 mm) Hood
Maximum length of 4” (102 mm) diameter metal duct.
Number of 90˚
elbows/bends
Rigid metal
Flexible metal
(fully extended)
0
90 ft
27.4 m
8 ft
2.4 m
1
60 ft
18.3 m
8 ft
2.4 m
2
45 ft
13.7 m
8 ft
2.4 m
3
35 ft
10.7 m
8 ft
2.4 m
4
25 ft
7.6 m
8 ft
2.4 m
Acceptable 2 ½” (64 mm) Hood (for short length installations)
4” Dia (102 mm)
2 1/2” (64 mm)
When you have a 2 ½” (64 mm) Hood
Maximum length of 4” (102 mm) diameter metal duct.
Number of 90˚
elbows/bends
Rigid
Flexible Metal
(fully extended)
0
60 ft
18.3 m
8 ft
2.4 m
1
45 ft
13.7 m
8 ft
2.4 m
2
35 ft
10.7 m
8 ft
2.4 m
3
25 ft
7.6 m
8 ft
2.4 m
4
15 ft
4.6 m
8 ft
2.4 m