7 | Technical data
FISCHER Mess- und Regeltechnik GmbH
96
BA_EN_DE90
Measuring range (Channel 1 2)
Overload
Bursting
pressure
Sensor
-16 … +16 mbar
-1.6 … +1.6 kPa
400 mbar
800 mbar
B
-25 … +25 mbar
-2.5 … +2.5 kPa
400 mbar
800 mbar
B
-40 … +40 mbar
-4 … +4 kPa
400 mbar
800 mbar
B
-60 … +60 mbar
-6 … +6 kPa
1 bar
2 bar
B
-100 … +100 mbar
-10 … +10 kPa
1 bar
2 bar
B
-160 … +160 mbar
-16 … +16 kPa
2.5 bar
5 bar
B
-250 … +250 mbar
-25 … +25 kPa
2.5 bar
5 bar
B
*)
Sensors can be delivered with a higher overload and bursting pressure capab-
ility with these measuring ranges (see order code/special aspects).
7.3 Output sizes
Analog outputs
The number of analog outputs depends on the device version. The output signal
can be set by parameterization. On delivery, both analog outputs are set to the
same signal (see nameplate).
Device Version
1-channel
2-channel
Number of analog outputs
1
2
Output signal
0 … 20 mA
4 … 20 mA
0 … 10 V
2 … 10 V
1 … 5 V
Signal range
0.0 … 21.5 mA
0.0 … 10.5 V
Load R
L
≤ 600 Ω
≥ 2 kΩ
Turn down
4:1
4:1
Switching outputs
The number of switching outputs depends on the device version. The assign-
ment of the switching outputs to the channels can be freely parameterised.
Device Version
1-channel
2-channel
Number of switching outputs
2
4
Assignment on Delivery
Switch output 1
Switch output 2
Switch output 3
Switch output 4
Type
Potential-free semiconductor switch (MOS-
FET)
Progr. switching function
Single pole make contact (NO)
Single pole break contact (NC)
max. switching voltage
3…32 V AC/DC
max. switching current
0.25 A
max. switching capacity
8 W / 8 VA
R
ON
≤ 4 Ω