5 | Operation
FISCHER Mess- und Regeltechnik GmbH
46
BA_EN_DE90
5.5.1.1 Mode C1
Directory: \Configuration\Channel 1\Modus K1
Level: 3
\...\...\Mode C1
1
2 3
4
Linear
Flow rate
Table
Volume flow
S
R
U
R
R
Option field
Fig. 57:
Mode C1
In this menu, various modes can be selected for the first measurement channel
(K1). The selected mode is indicated by the option field.
Parameter value
Description
Linear
Linear input characteristic curve
Flow rate
Flow measurements at an orifice plate
Table
Level measurements on tanks
Volume flow
Volumetric flow measurements in vent-
ilation systems
Linear function
Mathematical function
f(x) = mx + b
Back
E
This represents the output (exit) of the
menu. It takes you back to the Channel
3 menu.
Each of these operating modes requires a different parameterization of the
characteristic curve. After the exit of this menu, the calling menu will supple-
mented by the menu extension
Characteristic K1
, which parameterize
the characteristic curve.
The Linear operating mode is an exception. In this case, the menu extension is
not necessary because the parameters are only set in the
Measurement
C1
menu.
See also
2
Содержание PRO-LINE DE90
Страница 108: ...9 Attachments FISCHER Mess und Regeltechnik GmbH 108 BA_EN_DE90 Fig 141 CE_DE_DE90_ATEX ...
Страница 113: ...FISCHER Mess und Regeltechnik GmbH BA_EN_DE90 113 Notes ...
Страница 114: ...FISCHER Mess und Regeltechnik GmbH 114 BA_EN_DE90 ...
Страница 115: ...FISCHER Mess und Regeltechnik GmbH BA_EN_DE90 115 ...