FISCHER Mess- und Regeltechnik GmbH
Servicing | 5
BA_EN_MA15_ATEX
19 / 36
5 Servicing
5.1 Maintenance
To ensure reliable operation and a long service life, we recommend carrying out
the following test on a regular basis:
• Check the reading.
• Checking the switch function in connection with the downstream compon-
ents.
• Checking the pressure lines for leaks.
• Checking the electrical connections (terminal connection of the cable).
The precise test cycles and operating and ambient conditions need to be adjus-
ted. If several components of the unit interact, all operating instructions of the
other units also need to be observed.
WARNING
Dust deposits
The device must be cleaned with a damp cloth a regular intervals to prevent
heat build-up. Cleaning intervals depend on the amount of local dust.
5.2 Transport
The measuring device must be protected against impacts. It should be transpor-
ted in the original packaging or a suitable transport container.
5.3 Service
All defective or faulty devices should be sent directly to our repair department.
Please coordinate all shipments with our sales department.
WARNING
Process media residues
Process media residues in and on dismantled devices can be a hazard to
people, animals and the environment. Take adequate preventive measures. If
required, the devices must be cleaned thoroughly.
Return the device in the original packaging or a suitable transport container.
5.4 accessories
• Siphons MZ1###
• Capillary throttle coil MZ400#
• Settable damping reactor MZ410#
• Manometer shutoff valves MZ5###, MZ6###
Please see here the data sheet MZ measuring devices accessories. Here you
will find more detailed information about the technical data and the order codes
of the accessory parts MZ.
You can request the data sheet on request or via our webserver
www.fischer-
messtechnik.de
.
Содержание MA15F ... A Series
Страница 31: ...FISCHER Mess und Regeltechnik GmbH Attachments 8 BA_EN_MA15_ATEX 31 36 Fig 18 CE_DE_MA15F_1B_Page2...
Страница 32: ...8 Attachments FISCHER Mess und Regeltechnik GmbH 32 36 BA_EN_MA15_ATEX Fig 19 CE_DE_MA15F_1C_Page1...
Страница 33: ...FISCHER Mess und Regeltechnik GmbH Attachments 8 BA_EN_MA15_ATEX 33 36 Fig 20 CE_DE_MA15F_1C_Page2...
Страница 34: ...8 Attachments FISCHER Mess und Regeltechnik GmbH 34 36 BA_EN_MA15_ATEX Fig 21 CE_DE_MA15F_2D_Page1...
Страница 35: ...FISCHER Mess und Regeltechnik GmbH Attachments 8 BA_EN_MA15_ATEX 35 36 Fig 22 CE_DE_MA15F_2D_Page2...
Страница 36: ...8 Attachments FISCHER Mess und Regeltechnik GmbH 36 36 BA_EN_MA15_ATEX Fig 23 CE_DE_MA15F_0A...