Page 2

 

 

1.5 

Unauthorized Modification 

Modifications of or other technical alterations to the 
instrument  by  the  customer  are  not  permitted. This 
also  applies  to  replacement  parts.  Any  modifica-
tions  /  alterations  required  must  be  carried  out  by 
Fischer Mess- und Regeltechnik GmbH only. 

1.6 

Inadmissible Modes of Operation 

The  operational  safety  of  this  instrument  can  only 
be  guaranteed  if it is  used  as intended. The instru-
ment  model  must  be  suitable  for  the  medium  used 
in the system. The limit values given in the technical 
data may not be exceeded. 

1.7 

Safe working practices for mainte-
nance and installation work 

The safety instructions given in this operating man-
ual,  any  nationally  applicable  regulations  on  acci-
dent prevention and any of the operating company's 
internal  work, operating and safety  guidelines must 
be observed.  

The  operating  company  is  responsible  for  ensuring 
that all required maintenance, inspection and instal-
lation  work  is  carried  out  by  qualified  specialized 
personnel. 

1.8 

Symbol explanation 

 

WARNING! 

…  indicates  a  potentially  dangerous  situation, 
non-observance  of  which  could  endanger  per-
sons, animals, the environment or objects. 

 

 

 

INFORMATION! 

… highlights important information efficient and 
smooth operation. 

 

 

 

Tip! 

… indicates recommendations that are not spe-
cifically necessary in certain situations but which 
could be useful. 

 

 

Application purpose 

Display  and  switching  device  for  differential  pres-
sure of gaseous media. The instrument is to be ex-
clusively  used  for  the  applications  agreed  between 
the manufacturer and user. 

Description of the Product  

3.1 

Function diagram 

 

3.2 

Design and mode of operation 

This switching device is based on a capacitive sen-
sor element that is suitable for measuring overpres-
sure, underpressure and differential pressure.  

The measured pressure acts on the sensor element 
with a micromechanically produced differential con-
denser in silicon-glass technology. 

Changes in pressure generate changes in capacity, 
which  is  evaluated  by  the  device's  electronics  and 
transformed into signals on the display, switch con-
tacts and an output signal. 

Installation and assembly 

At  the  factory,  the  device  is  calibrated  for  vertical 
installation,  but  the  installation  position  is  arbitrary. 
For  any  installation  positions  that  are  not  vertical, 
the  zero-point  signal  can  be  corrected  via  the  in-
stalled offset corrector. 

The enclosure protection type IP 65 is only guaran-
teed, if a suitable power supply cable is used.  

If  the  device  is  intended  for  outdoor  use,  we  rec-
ommend  permanently  protecting  the  membrane 
keypad  against  UV  radiation  and  using  a  suitable 
enclosure  or  at  least  the  erection  of  a  sufficiently 
dimensioned  canopy  as  a  protection  measure 
against constant rain or snow. 

Analogue- 

output 

Display 

Switch contacts 

Keyboard 

Switch 

output 

Δp 

Sensor element 

Electronics 

Содержание DE46

Страница 1: ...fety instructions the in tended use of the device or the limit values given in the technical specifications can be hazardous or cause harm to persons the environment or the plant itself Fischer Mess u...

Страница 2: ...situations but which could be useful 2 Application purpose Display and switching device for differential pres sure of gaseous media The instrument is to be ex clusively used for the applications agre...

Страница 3: ...nsing lines 4 2 Electronic connection By authorized and qualified specialized person nel only The electrical connection of the instrument shall be performed according to relevant VDE and local electri...

Страница 4: ...re menu select Quit and press Example Setting the switch points In normal mode press the button to enter the menu Menu level Switch points appears in the display to change the switch points press the...

Страница 5: ...measuring cell corresponds to that of a capillary throttle You can set the response time to pressure jumps in the range 0 0 to 100 s But with maximum damping it will take more than 2 minutes for the r...

Страница 6: ...EAR is active the other menu items are cancelled Square rooted Here the input signal is square rooted before being sent to the display and the out put This is necessary e g for flow measurements with...

Страница 7: ...nt unwanted colour changes Here the colour change can be delayed in the range between 0 100s The following applies for instruments with firmware 2 16 and later Here the colour change can be delayed in...

Страница 8: ...wn stream components Check the leak tightness of the pressure con nection lines Check the electrical connections The exact test cycles shall be adapted to the oper ating and ambient conditions If vari...

Страница 9: ...g voltage Ub 20 32 V DC AC Connection type Three wire Output signal 0 20 mA 4 20 mA 0 10 V DC Apparent ohmic resistance Ub 26V RL Ub 4V 0 02A Ub 26V RL 1100 RL 2 k Power consumption approx 2 W VA Meas...

Страница 10: ...nless otherwise specified 90 75 25 5 M12 plug connection Wall mounting plate optional Rear view without wall mounting plate 70 5 61 5 4x boreholes for Tapping screws 3 5 Hose screw connection for 6 or...

Страница 11: ...DC AC 20 32 V DC AC N Measuring unit Selectable pressure units W Measured value display contact elements 4 digit colour change LCD 2 relay contacts C 4 digit colour change LCD 2 semiconductor switch...

Страница 12: ...without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesstechnik de www...

Отзывы: