Installation Instructions
Seite/Page 66 Panda_4800i PMS_eng.R04 - Kapitel/Chapter 5: Installation Instructions
14.2.13
5.5
Installation of the water cooled exhaust system
5.5.1 Installation of the standard exhaust system
The generator exhaust system must remain completely independent and separate from the exhaust system of any
other unit(s) on board. The water lock must be installed at the lowest point of the exhaust system. An optional noise
insulated water lock can also be installed. The exhaust hose descends from the capsule to the water lock. Then the
hose rises via the „goose neck“ to the silencer (see drawing). The goose neck must be vertical and sit preferably
along the ship's keel centre line. In order that the back pressure inside the exhaust is not to high, the total length of
the exhaust system should not exceed 6,3 m.
By injecting the outlet raw water into the exhaust manifold, the exhaust gases are cooled and the noise emissions
from the exhaust system are reduced.
Exhaust diameter see section 8.10, “Diameter of conduits,”
on page 224
Содержание Panda 4800i PMS
Страница 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 14 2 13 Leere Seite Intentionally blank Basics ...
Страница 54: ...The Panda Generator Seite Page 54 Panda_4800i PMS_eng R04 Kapitel Chapter 4 The Panda Generator 14 2 13 ...
Страница 130: ...Seite Page 130 Panda_4800i PMS_eng R04 14 2 13 Leere Seite Intentionally blank Tables ...
Страница 148: ...Page 148 Chapter 2 General operation 14 2 13 Intentionally left blank General operation ...
Страница 152: ...Installation Page 152 Chapter 3 Installation 14 2 13 3 3 Dimensions Fig 3 3 1 Housing of the Panda iControl2 panel ...
Страница 156: ...Page 156 Chapter 3 Installation 14 2 13 Intentionally left blank Installation ...
Страница 158: ...Page 158 Chapter 4 Maintenance 14 2 13 Intentionally left blank Maintenance ...
Страница 164: ...Page 164 Chapter 6 Annex 14 2 13 Intentionally left blank Annex ...