Warnings and error messages
14.2.13
Chapter 5: Warnings and error messages - Page 161
5.2.1 Error messages
All error messages defined for the Panda iControl 2 and the corresponding display texts are compiled in the
subsequent table.
Fig. 5.2.1-1: Error messages
Error messages can be acknowledged with the Start/Stop button, The controller will then return to stand-by mode.
5.2.2 Warning and fault thresholds
The threshold values resulting in triggering warnings and faults depend on the generator type and are compiled in
table 2-3.
Fig. 5.2.2-1: Warning and fault thresholds for different generator types
Error message on the display
Meaning of error message
FAULT: CYL.HEAD
Cylinder head temperature too high
FAULT: WINDING
Winding temperature too high
FAULT: EXHAUST
Exhaust manifold temperature too high
NO CONNECTION BUS ERROR
Communication error on Fischer Panda bus
STARTING FAILS
Generator start has failed
PROBLEM WITH FUEL SUPPLY!
Fuel supply not suitable
FAULT: OILPRESS
Oil pressure error
BATTERY LOW
Battery power too low
Inverter overtime
Inverter temperature too high
Inverter overload
Generator was overloaded, message is also issued when the generator output cable
is not connected to the inverter
INIT FAILED!
Parameters were not correctly adopted into the EEPROM when the generator type was
initialised. Generator type must be reset.
„OUT“ is output instead of a temperature
„Out of range“ - broken cable on corresponding temperature sensor
Generator type
Warning/fault
Warning threshold
Fault threshold
5000i marine
Cylinder head temperature
Delay
85 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
1 s
75 °C
1 s
5000i vehicle
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
100 °C
1 s
105 °C
1 s
P8000i / P10000i marine
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
1 s
75 °C
1 s
P8000i / P10000i vehicle
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
100 °C
1 s
105 °C
1 s
Содержание Panda 4800i PMS
Страница 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 14 2 13 Leere Seite Intentionally blank Basics ...
Страница 54: ...The Panda Generator Seite Page 54 Panda_4800i PMS_eng R04 Kapitel Chapter 4 The Panda Generator 14 2 13 ...
Страница 130: ...Seite Page 130 Panda_4800i PMS_eng R04 14 2 13 Leere Seite Intentionally blank Tables ...
Страница 148: ...Page 148 Chapter 2 General operation 14 2 13 Intentionally left blank General operation ...
Страница 152: ...Installation Page 152 Chapter 3 Installation 14 2 13 3 3 Dimensions Fig 3 3 1 Housing of the Panda iControl2 panel ...
Страница 156: ...Page 156 Chapter 3 Installation 14 2 13 Intentionally left blank Installation ...
Страница 158: ...Page 158 Chapter 4 Maintenance 14 2 13 Intentionally left blank Maintenance ...
Страница 164: ...Page 164 Chapter 6 Annex 14 2 13 Intentionally left blank Annex ...