2.6.3 Terminal connections
Connection for the automatic adapter X2 (row with odd pin numbers // I/O view from operating panel)
Fig. 2.6.3-1: Terminal connections automatic adapter
2.7
Master-Slave adapter - optional
2.7.1 Fischer Panda Art. No. 21.02.02.015P, 12 V-version
Fig. 2.7.1-1: Panel 21.02.02.046P with master-slave adapter 21.02.02.015P
Pin-no.
Pin-name
I / O
Description
1
VBF
O
power (operation voltage behind fuse)
3
GND
O
power supply - (ground)
5
VBFS
O
power switched (voltage Pin 1, with panel switched on)
7
12V
O
power switched, at 12 V-operation over closed soldered jumper J101 connected with
VBFS (at optional 24 V-operation: VBFS over internal voltage regulator at 12,9 V regulated)
9
GND
O
power supply - (ground)
11
GND
O
power supply - (ground)
13
/Heat-signal
I
Heat is active, if the input is switched to GND
15
/Start-signal
I
Start is active, if the input is switched to GND
17
GND
O
power supply - (ground)
19
GND
O
power supply - (ground)
21
GND
O
power supply - (ground)
23
GND
O
power supply - (ground)
25
GND
O
power supply - (ground)
27
/Stop-signal
I
The Fuel pump signal is switched off, as long as the input is switched to GND, (also when starting)
29
FP-Int
O
Fuel pump signal internally, decoupled over diode from external signal
31
/Fault-signal
O
Output is switched to GND, if an error is present (inputs 3, 4, 5, 11 and 12, if configured and
generally for 2 s, after switching on the panel)
33
GND
O
power supply - (ground)
01
02
01. Main terminals
02. Master-slave adapter 21.02.02.015P
Содержание 0000139
Страница 4: ...Seite Page 4 Kapitel Chapter 1 10 5 17 Leere Seite Intentionally blank ...
Страница 26: ...Seite Page 26 Kapitel Chapter 2 General operation 10 5 17 Leere Seite Intentionally blank General operation ...
Страница 28: ...Seite Page 28 Kapitel Chapter 3 Measurements 10 5 17 Leere Seite Intentionally blank Measurements ...