background image

 

 

 

STEP 9:

 

Cut main supply line as required to fit plumbing to inlet and outlet of bypass valve. 

STEP 10:

 

Attach plumbing.  DO NOT apply heat to any fitting connected to bypass valve or control valve, 
as  damage  may  result  to  internal  parts  or  connecting  adapters.    MAKE  CERTAIN  WATER 
ENTERS THROUGH 

INLET 

AND DISCHARGES THROUGH 

OUTLET 

(See figure 2). 

STEP 11: 

Use the provided polyethylene tubing (

NO VINYL TUBING

) to run drain line from control valve 

discharge fitting to floor drain or sump pit capable of handling the backwash rate of the filter 
(refer to specifications and flow rate on page 14).  There must be an air gap at the end of the 
drain  line  to  prevent  siphoning  of  waste  wa

ter.    Length  of  drain  line  should  be  15’  or  less.  

AVOID OVERHEAD DRAINS

.   

STEP 12: 

MAKE SURE THE BYPASS VALVE IS IN THE “BYPASS” POSITION

  (Figure  4,  Page  5) 

and open the main supply valve or turn on power to the pump on private well systems. 

STEP 13:

 

For  the  NBW  Series  rotate  the  Manual  Regeneration  Knob  (see  Fig.  5,  page  7)  to  the 
“Backwash” position.  

 

For the NEBW Series plug transformer into an un-switched electrical outlet and attached the 
power cord to the control valve. Then press and hold down the 

center “ADVANCE” button for 5 

seconds and release after “GO TO BW” appears on the screen (see Figure 6, page 8). When 
the valve stops in backwash position, unplug the transformer from the electrical outlet. 

STEP 14:

 

Refer to Figure 4 on page 5 for appropriate bypass valve operation.  Rotate bypass lever of 
stainless  steel  bypass  ¼  of  the  way  to  Service  allowing  unit  to  fill  slowly. 

IMPORTANT:  

Activated  Carbon,  Filter  Ag  and  Birm  must  be  soaked  for  at  least  2  hours  prior  to 
submitting it to full flow rate to prevent loss of media to drain.

   

When all air has been purged from the system and only water is running to the drain, fully open 
bypass valve to the “Service” position and allow the NBW/NEBW to backwash for 10 minutes 
or until the water runs clear (whichever is longer). 

STEP 15: 

Plug  the  softener  into  an  un-switched  electrical  outlet  and  allow  the  unit  to  complete 
regeneration automatically. 

STEP 18:

 

Check for leaks and correct as necessary. 

STEP 19:

  

Turn power or fuel supply back on to water heater. 

STEP 20:

 

Set  the  regeneration  frequency  (refer  to  timer  operation  for  instruction  on  page  5  for  NBW 
Series). The NEBW units determine frequency base on gallons used.   

STEP 21: 

Set the current time of day on the timer (note AM and PM) (refer to Figure 5, page 7 or Figure 
6, page 8). 

RECOMMENDED:  

Retain the red distributor cap and blue media funnel for future replenishment of filter media. 

NOTE:  If the filter is loaded with any self-sacrificing media like Calcite or Neutralizer, mark the media 
level on the side of the tank by shining a bright light through the tank to see its level.  Replenish the 
media in the mineral tank when the level drops by more than three inches. 

Installation Instructions (cont.) 

Содержание NBW10

Страница 1: ...LC 12630 US Highway 33 N Churubusco IN 46723 Phone 260 693 1972 Fax 260 693 0602 NBW NEBW Series Installation Manual 170623 docx NBW NEBW Series Backwashing Filter System Installation Instructions and Owner s Manual ...

Страница 2: ...nic Display Operation Page 8 NEBW Electronic Programming Page 9 Specifications Page 11 Component Parts Breakdown List Page 12 NBW Control Valve Breakdown Page 13 NBW Control Valve Parts List Page 14 NEBW Control Valve Breakdown Page 15 NEBW Control Valve Parts List Page 16 Troubleshooting Page 17 Ten Year Limited Warranty Page 19 Table of Contents ...

Страница 3: ... 50 PAIL 45 FA10 FILTER AG SUSPENDED SOLIDS REDUCTION 1 00 BAG 24 FA05P 0 50 PAIL 12 ZEO10 ZEOLITE SUSPENDED SOLIDS SEDIMENT REDUCTION 1 00 BAG 25 Z05P 0 50 PAIL 50 N05 NEUTRALIZER ACID NEUTRALIZER 0 50 PAIL 43 QFS05P QUARTZ FILTER SAND 0 50 PAIL 51 45mm x 55mm SEDIMENT REDUCTION Successful Application Any filter media may have specific limitations and or requirements for successful application A ...

Страница 4: ...this system 1 The NBW NEBW must be installed after the pressure tank private well system only 2 The system should be installed as close as possible preferably within 15 to an adequate floor or laundry drain capable of handling the backwash cycle volume and flow rate refer to unit specifications An air gap should be provided between the NBW NEBW drain line and plumbing drain 3 All water conditionin...

Страница 5: ...ere O Ring seals are used NOTE If the plumbing system is used as the ground leg of the electric supply continuity should be maintained by installing ground straps around any non conductive plastic piping or bypass used in the installation Make sure the filter is not installed backwards The filter will not function properly if installed backwards and filter media may be forced into the water lines ...

Страница 6: ...ft empty at the top of the mineral tank to allow for media bed expansion during backwash and to prevent filter media from being discharged through the drain line STEP 5 Use a garden hose or bucket to fill the media tank with water IMPORTANT Carbon Filter Ag Zeolite and Birm must be soaked for at least 2 hours prior to submitting it to full backwash flow rate to prevent loss of media to drain STEP ...

Страница 7: ...transformer from the electrical outlet STEP 14 Refer to Figure 4 on page 5 for appropriate bypass valve operation Rotate bypass lever of stainless steel bypass of the way to Service allowing unit to fill slowly IMPORTANT Activated Carbon Filter Ag and Birm must be soaked for at least 2 hours prior to submitting it to full flow rate to prevent loss of media to drain When all air has been purged fro...

Страница 8: ...inter Each number represents a day The number by the red pointer is tonight 2 Slide the metal tabs outward on the desired days of backwash Factory default setting is every third day How to Manually Initiate a Regeneration Cycle 1 Grab the manual regeneration knob and turn clockwise SLIGHTLY 2 The drive gear will engage the regeneration knob which will make a complete revolution and return to the S...

Страница 9: ...nitiate an immediate regeneration cycle 2 Press and release Advance Button during a regeneration cycle to immediately advance the valve to the next step in the regeneration process 3 When the valve is in Programming Mode press the Advance Button to move the cursor UP BUTTON 1 When the valve is in the Programming Mode press Up Button to adjust setting NEBW Electronic Display Operation Advance Butto...

Страница 10: ...Mode Press and Hold the SET Button for 5 seconds NEBW Electronic Programming Use Up Button to set current hour Use Up Button to set current minute Use Up Button to set AM PM DO NOT change this setting Exit Programming Mode ...

Страница 11: ...10 This page intentionally left blank ...

Страница 12: ...dia Volume cu ft 1 0 1 5 2 0 Gravel Underbed lbs 20 20 25 Operating Flow Rate gpm Continuous no duration limit 5 gpm ft2 2 3 4 Service intermittent flow up to 10 gpm ft2 5 6 8 Peak 10 mins or less 15 gpm ft2 8 9 12 Backwash Flow Rate 5 5 7 Service Pipe Size in Standard 1S Suffix on Model Number 1 1 1 Factory Programming Settings Day Override Setting 3 3 3 Regeneration Time 1 00 AM 1 00 AM 1 00 AM ...

Страница 13: ...BP NEBW20 Vlv Assy w BP 2 Mineral Tank MTP1044N MTP1054N MTP1248N 3 Distributor D100S 48 D100S 54 D100S 48 4 Media Qty See page 2 for list 1 cu ft 1 5 cu ft 2 cu ft 5 1 4 X 1 8 Gravel QC20 QC20 QC25 6 Top Screen 18280 02 18280 02 18280 02 Notes 1 Refer to pages 13 14 for complete control valve breakdown of time clock initiated control valves and pages 15 16 for meter initiated control valves Compo...

Страница 14: ...13 NBW Time Clock Control Valve Breakdown ...

Страница 15: ...60041SS Bypass Valve Stainless 1 NPT Optional use 1S suffix 1 18743 1 Motor 120v 60hz 1 30 RPM 2 13304 O Ring Distributor 121 3 12281 O Ring Tank 338 4 12092 Flow Control Washer 5 0 GPM NBW10 NBW15 12408 Flow Control Washer 7 0 GPM NBW20 5 NE DRAIN ELB Drain Elbow Quick Connect x barbed 6 NE DRAIN CLIP Quick Release Clip Drain Elbow 7 NE CON ORG Connector O Ring 8 14105 Bypass Valve Seal Single Le...

Страница 16: ...15 NEBW Electronic Control Valve Breakdown ...

Страница 17: ...alve 60041SS 1 Stainless Steel Bypass Valve Optional add 1 to model number 1 42349 Motor 24v 60hz 2 RPM 2 NE TRANS Transformer 110v Input 24v Output 3 13304 O Ring Distributor 121 4 12281 O Ring Tank 338 9 12092 Flow Control Washer 5 0 GPM for model CS 1 CS 1 5 10 NE DRAIN ELB Drain Elbow Quick Connect x barbed 11 NE DRAIN CLIP Quick Release Clip Drain Elbow 12 NE CON ORG Connector O Ring 13 14105...

Страница 18: ... water usage flow rates against system specifications 5 Increase length of backwash and rinse cycles Neutralizer media raises pH too high A Filter is brand new B Wrong media used 1 Turn bypass valve very slightly to the Bypass position allowing a small amount of untreated water to bleed into the treated water 2 Rebed the unit with a less aggressive media Neutralizer media fails to raise pH suffici...

Страница 19: ...motor faulty 1 Ensure electrical outlet is functioning 2 Disassemble and clean control valve 3 Replace seals and or piston 4 Replace faulty drive motor Media in the service lines A Unit installed backwards 1 Re plumb the water lines so that the supply side of the line is connected to the inlet of the bypass and the service side is connected to the outlet Troubleshooting cont ...

Страница 20: ...function occur contact the dealer that you purchased the product from If you are unable to contact the dealer contact First Sales LLC 260 693 1972 We will require a full description of the problem model number date of purchase and selling dealer s business name and address We assume no warranty liability in connection with this water conditioner other than specified herein This warranty is in lieu...