background image

 

 

STEP 1:

 

Carefully remove all components from packaging.  DO NOT DISCARD PACKAGING until all 
backwash system components and fittings have been located. 

STEP 2:

 

Place unit at desired installation position. Be sure the location is within 15 feet of a drain that is 
lower than the control valve and near a non-switched electrical outlet.  Also, ensure the tank is 
on a level and firm base.  Install the unit with at least 10 feet of piping before the water heater 
to prevent hot water from backing into the filter.  Turn off the main water supply and drain the 
system.  

STEP 3:

 

With  the  backwash  filter  unit  in  the  upright  position, 

remove  the  control  valve

  from  the 

mineral tank being careful to not pull the distributor out of the gravel at the bottom of the tank..

  

STEP 4:

 

Cover  the  top  of  the  distributor  tube  with  the  included  red  cap  and,  using  the  included  blue 
media funnel, 

pour filter media(s) (purchased separately) into the mineral tank

.  If using 

multiple filter media types, load in the order of heaviest (most dense) to lightest (least dense). 
12” – 14” of space MUST be left empty at the top of the mineral tank to allow for media bed 
expansion  during  backwash  and  to  prevent  filter  media  from  being  discharged  through  the 
drain line. 

STEP 5: 

Use a garden hose or bucket to 

fill the media tank with water

.   

IMPORTANT:  Carbon, Filter Ag, Zeolite and Birm must be soaked for at least 2 hours 
prior to submitting it to full backwash flow rate to prevent loss of media to drain.

   

STEP 6: 

Clean mineral tank threads to remove any filter media.  Remove red cap from distributor tube 
and reinstall control valve by threading it securely onto the mineral tank. (O-ring seal; HAND 
TIGHTEN ONLY!). 

STEP 7:

 

If not factory installed, use the clips and screws provided and attached the bypass valve to the 
inlet/outlet of the control valve. See Figures 2, 3, and 4 below.  

 

 

 

 

 

 

 

 

 

 

 

STEP 8: 

Shut off all water at main supply.  On private well system, turn off power to pump and drain 
pressure tank.  Make certain pressure is relieved from complete system by  opening nearest 
faucet to drain system.  SHUT OFF FUEL / ELECTRICAL SUPPLY TO WATER HEATER. 

Installation Instructions 

FIGURE 2:  Top View of NBW Control Valve 

FIGURE 4:  Bypass Valve 

CONTROL VALVE 

METER MODULE 

BYPASS  
IN SERVICE  
POSITION 

OUT 

IN 

RETAINER CLIPS 

DRAIN ELBOW 

ELBOW LOCKNG CLIP 

FIGURE 3:  Top View of NEBW Control Valve 

Содержание NBW10

Страница 1: ...LC 12630 US Highway 33 N Churubusco IN 46723 Phone 260 693 1972 Fax 260 693 0602 NBW NEBW Series Installation Manual 170623 docx NBW NEBW Series Backwashing Filter System Installation Instructions and Owner s Manual ...

Страница 2: ...nic Display Operation Page 8 NEBW Electronic Programming Page 9 Specifications Page 11 Component Parts Breakdown List Page 12 NBW Control Valve Breakdown Page 13 NBW Control Valve Parts List Page 14 NEBW Control Valve Breakdown Page 15 NEBW Control Valve Parts List Page 16 Troubleshooting Page 17 Ten Year Limited Warranty Page 19 Table of Contents ...

Страница 3: ... 50 PAIL 45 FA10 FILTER AG SUSPENDED SOLIDS REDUCTION 1 00 BAG 24 FA05P 0 50 PAIL 12 ZEO10 ZEOLITE SUSPENDED SOLIDS SEDIMENT REDUCTION 1 00 BAG 25 Z05P 0 50 PAIL 50 N05 NEUTRALIZER ACID NEUTRALIZER 0 50 PAIL 43 QFS05P QUARTZ FILTER SAND 0 50 PAIL 51 45mm x 55mm SEDIMENT REDUCTION Successful Application Any filter media may have specific limitations and or requirements for successful application A ...

Страница 4: ...this system 1 The NBW NEBW must be installed after the pressure tank private well system only 2 The system should be installed as close as possible preferably within 15 to an adequate floor or laundry drain capable of handling the backwash cycle volume and flow rate refer to unit specifications An air gap should be provided between the NBW NEBW drain line and plumbing drain 3 All water conditionin...

Страница 5: ...ere O Ring seals are used NOTE If the plumbing system is used as the ground leg of the electric supply continuity should be maintained by installing ground straps around any non conductive plastic piping or bypass used in the installation Make sure the filter is not installed backwards The filter will not function properly if installed backwards and filter media may be forced into the water lines ...

Страница 6: ...ft empty at the top of the mineral tank to allow for media bed expansion during backwash and to prevent filter media from being discharged through the drain line STEP 5 Use a garden hose or bucket to fill the media tank with water IMPORTANT Carbon Filter Ag Zeolite and Birm must be soaked for at least 2 hours prior to submitting it to full backwash flow rate to prevent loss of media to drain STEP ...

Страница 7: ...transformer from the electrical outlet STEP 14 Refer to Figure 4 on page 5 for appropriate bypass valve operation Rotate bypass lever of stainless steel bypass of the way to Service allowing unit to fill slowly IMPORTANT Activated Carbon Filter Ag and Birm must be soaked for at least 2 hours prior to submitting it to full flow rate to prevent loss of media to drain When all air has been purged fro...

Страница 8: ...inter Each number represents a day The number by the red pointer is tonight 2 Slide the metal tabs outward on the desired days of backwash Factory default setting is every third day How to Manually Initiate a Regeneration Cycle 1 Grab the manual regeneration knob and turn clockwise SLIGHTLY 2 The drive gear will engage the regeneration knob which will make a complete revolution and return to the S...

Страница 9: ...nitiate an immediate regeneration cycle 2 Press and release Advance Button during a regeneration cycle to immediately advance the valve to the next step in the regeneration process 3 When the valve is in Programming Mode press the Advance Button to move the cursor UP BUTTON 1 When the valve is in the Programming Mode press Up Button to adjust setting NEBW Electronic Display Operation Advance Butto...

Страница 10: ...Mode Press and Hold the SET Button for 5 seconds NEBW Electronic Programming Use Up Button to set current hour Use Up Button to set current minute Use Up Button to set AM PM DO NOT change this setting Exit Programming Mode ...

Страница 11: ...10 This page intentionally left blank ...

Страница 12: ...dia Volume cu ft 1 0 1 5 2 0 Gravel Underbed lbs 20 20 25 Operating Flow Rate gpm Continuous no duration limit 5 gpm ft2 2 3 4 Service intermittent flow up to 10 gpm ft2 5 6 8 Peak 10 mins or less 15 gpm ft2 8 9 12 Backwash Flow Rate 5 5 7 Service Pipe Size in Standard 1S Suffix on Model Number 1 1 1 Factory Programming Settings Day Override Setting 3 3 3 Regeneration Time 1 00 AM 1 00 AM 1 00 AM ...

Страница 13: ...BP NEBW20 Vlv Assy w BP 2 Mineral Tank MTP1044N MTP1054N MTP1248N 3 Distributor D100S 48 D100S 54 D100S 48 4 Media Qty See page 2 for list 1 cu ft 1 5 cu ft 2 cu ft 5 1 4 X 1 8 Gravel QC20 QC20 QC25 6 Top Screen 18280 02 18280 02 18280 02 Notes 1 Refer to pages 13 14 for complete control valve breakdown of time clock initiated control valves and pages 15 16 for meter initiated control valves Compo...

Страница 14: ...13 NBW Time Clock Control Valve Breakdown ...

Страница 15: ...60041SS Bypass Valve Stainless 1 NPT Optional use 1S suffix 1 18743 1 Motor 120v 60hz 1 30 RPM 2 13304 O Ring Distributor 121 3 12281 O Ring Tank 338 4 12092 Flow Control Washer 5 0 GPM NBW10 NBW15 12408 Flow Control Washer 7 0 GPM NBW20 5 NE DRAIN ELB Drain Elbow Quick Connect x barbed 6 NE DRAIN CLIP Quick Release Clip Drain Elbow 7 NE CON ORG Connector O Ring 8 14105 Bypass Valve Seal Single Le...

Страница 16: ...15 NEBW Electronic Control Valve Breakdown ...

Страница 17: ...alve 60041SS 1 Stainless Steel Bypass Valve Optional add 1 to model number 1 42349 Motor 24v 60hz 2 RPM 2 NE TRANS Transformer 110v Input 24v Output 3 13304 O Ring Distributor 121 4 12281 O Ring Tank 338 9 12092 Flow Control Washer 5 0 GPM for model CS 1 CS 1 5 10 NE DRAIN ELB Drain Elbow Quick Connect x barbed 11 NE DRAIN CLIP Quick Release Clip Drain Elbow 12 NE CON ORG Connector O Ring 13 14105...

Страница 18: ... water usage flow rates against system specifications 5 Increase length of backwash and rinse cycles Neutralizer media raises pH too high A Filter is brand new B Wrong media used 1 Turn bypass valve very slightly to the Bypass position allowing a small amount of untreated water to bleed into the treated water 2 Rebed the unit with a less aggressive media Neutralizer media fails to raise pH suffici...

Страница 19: ...motor faulty 1 Ensure electrical outlet is functioning 2 Disassemble and clean control valve 3 Replace seals and or piston 4 Replace faulty drive motor Media in the service lines A Unit installed backwards 1 Re plumb the water lines so that the supply side of the line is connected to the inlet of the bypass and the service side is connected to the outlet Troubleshooting cont ...

Страница 20: ...function occur contact the dealer that you purchased the product from If you are unable to contact the dealer contact First Sales LLC 260 693 1972 We will require a full description of the problem model number date of purchase and selling dealer s business name and address We assume no warranty liability in connection with this water conditioner other than specified herein This warranty is in lieu...