18
PROBLEM
CAUSES
SOLUTIONS
Continuous flow of
water to drain
A) Loss of electrical
power during
regeneration
B) Debris in control
valve
C) Internal leak in
control valve
D) Timer motor faulty
1) Ensure electrical outlet is functioning
2) Disassemble and clean control valve
3) Replace seals and/or piston
4) Replace faulty drive motor
Media in the
service lines
A) Unit installed
backwards
1) Re-plumb the water lines so that the
supply side of the line is connected to the
inlet of the bypass and the service side is
connected to the outlet.
Troubleshooting (cont.)