Troubleshooting
Fault
Probable Cause
Solution
Water changes
color or becomes
cloudy.
Rower is in direct
sunlight or has not
had water
treatment.
Change rower location to reduce direct
exposure to sunlight. Add water treatment
or change tank water as directed in the
water treatment section of this manual.
Consider using distilled water to refill tank.
Rowing stroke
return is too light.
Bungee not under
enough tension.
Open rear Perspex cover, cut bungee tie
wrap . Tighten by small increments using
the bungee tie off tab point and test
tension by allowing the rowing handle to
return to its furthest point forward while
still having some slight tension. Note light
fraying of the bungee cord is normal.
Rower rocks from
side to side when
sitting on floor
Front/Rear frame
levelers need
adjusting
Adjust the front two frame levelers or rear
leg levelers until stability is reached. Note:
It is normal for the lower rear leveler to
rest slightly off the floor.
Front of rower lifts
slightly during
vigorous rowing.
Lower rear frame
leveler too high.
Check to see that frame tensioning bolt is
tightened properly. Lower rear frame
leveler should be approx. 5mm off the
ground.
Computer screen
illuminates, but
does not register
when rowing.
Loose or failed
connection/Sensor
gap too wide (see
erratic computer
display).
Check that the computer lead is connected
properly. If connected properly check
sensor gap. Contact your local service
center if this fails to address the problem.
The Rower comput-
er does not illumi-
nate after battery
installation.
Batteries installed
incorrectly or need
replacing.
Reinstall batteries in correct position and
try again. If the LCD screen fails to
illuminate, try rotating the batteries
slightly in the computer. If this fails,
contact your local service center.
The Rower comput-
er display is erratic
while displaying
SPM and 500meter
times.
Gap between
sensor and
magnetic ring is
too wide.
Adjust sensor location using rear sliding
adjustment located inside rear Perspex
cover.
Excessive frame flex
during hard rowing.
Frame Tension
Cable is too loose
Loosen frame tension cable Retaining Nut
and tighten cable until taut.
Содержание Fluid FR-E316