OM/SM-TDB/7(CE)
18
the value corresponding to the dial setting, the
thermostat switch opens. This turns off the heating
indicator light and causes the contactors to open,
stopping the power to the heaters.
As soon as the thermostat senses that the kettle is
cooling below the set point, the thermostat switch
closes, the heating indicator light comes on, the
contactors close, and the heaters come on again. On-
off cycling continues, keeping the kettle at the set
temperature. This is why the heating indicator light
cycles on and off during normal operation. Every time
the kettle is tilted, the tilt cut-off switch interrupts the
power supply to the heaters, so that the heating
elements will not operate while not submerged in the
jacket water.
If steam pressure greater than 50 PSIG is generated
in the jacket, the safety valve will open and relieve the
excess pressure.
If the jacket water level gets too low before the
heating elements overheat, the high-limit control will
open and shut off power to the elements until the
kettle cools.
Setting the operating thermostat dial to “OFF” shuts
down all control and heating circuits.
6. To Empty Kettle
TDB/7 Kettles with Crank Tilt
To tilt the body of the kettle forward, turn the hand
crank on the front of the cabinet anti-clockwise. The
body will stay in the position it holds when you stop
turning the handle. To return the body to the upright
position, turn the crank clockwise.
TDB/7 Kettle with Tilt Handle
The kettle is designed to be tilted in a controlled
manner. Grasp the insulated plastic ball firmly.
Maintain a firm grip on the handle when tilting, while
keeping the kettle body in a tilted position, and when
slowly
returning the kettle body to an upright
position.
WARNING
DO NOT STAND IN FRONT OF THE KETTLE
BODY WHEN TILTING IT. BE CAREFUL TO
KEEP HOT CONTENTS FROM SPILLING.
ENSURE PEOPLE ARE KEPT AWAY FROM
THE KETTLE WHEN EMPTYING THE KETTLE.
7. Power Failure
If the power to the unit fails do not attempt to
operate the appliance until the electricity supply is
re-established.
When the power comes back on follow the steps in
Paragraph 8.2.1 Initial Kettle Operational Readiness
Check.