First Alert ReadyGuard-RI Скачать руководство пользователя страница 4

Step

 

Action

 

3.

 

Enhanced Sequential Mode  - Press *83, then follow the prompts as follows: 

 

A           01 

a.  Zone Number  -  Enter 2-digit zone number of the first transmitter to have its serial number 

entered. The system will announce the Voice Descriptor for the selected zone number, if it is 
programmed.  

 

 

 

Press [*] to continue. Starting with this zone, the system will search for the first transmitter, 
which has all of the following attributes pre-programmed in Zone Programming. 

 

 

1)  The correct input type selected in *56 (RF, UR, or BR programmed) 

 

 

2)  The correct loop number selected in *56 

 

 

3)  No serial number programmed  

 

 

4)  Zone type  

Notes: 

1.  If the first zone number entered does 

not

 have one or more of the above attributes, the system will 

search its database for the first zone that does, and will display it at the ENROLL SERIAL NUMBER 
prompt (1b). 

 

2.  Pressing 00 exits mode, upon which the prompt “83” blinks, indicating the mode is inactive.  

 

1A

  

zz

 

 

b.  Enroll Mode -

 

If “

L

” is displayed, the serial number for this transmitter has already been entered, 

however, it may still be confirmed, viewed or deleted.  
1)   If the transmitter’s serial number has not been previously entered, enter the enroll serial 

number mode now by pressing “1”, or copy the last serial number that was entered by 
pressing “2”. 

 

1A

  

LC

  

 

2)  If the transmitter’s serial number has been previously entered, it may be viewed by pressing 

“3” or deleted by pressing “9”.  

Note: 

If view is selected; each digit will be re-displayed, and the keypad will beep once for digits 1-6, and three 
times for the last digit. 

 

 

3)  Once the serial number has been entered the system will return to the (1A) prompt and “

L

” 

will be displayed.  

Note: 

This point can be faulted and restored and the panel will listen for the transmission.  

4)  The serial number/loop number combination that was entered can be confirmed by faulting 

and restoring the zone being entered. If the panel receives a transmission that matches the 
serial number and loop number entered, the keypad will beep three times, and “C” will be 
displayed. This indicates that the serial number transmission has been confirmed to match. 
No further transmissions will be received.  

Note: 

When confirming a 4-button key, it assumed that all loops are used and only the serial number is 
confirmed. Pressing any key will allow a confirm. Two beeps indicate that the template has been 
accepted. A single long beep indicates illegal entries, or duplicate serial number/loop entry. 

 

5)  When the last zone has been entered, the display will remain on that zone. To exit this mode 

and return to data field program mode, press 00 at the ZONE NUMBER prompt 

 

6)  Once all zones have been programmed, test each zone using the system’s Test mode. Do 

not use the Transmitter ID Sniffer mode for this, since it will only check for transmission of 
one zone on a particular transmitter, and not the zones assigned to each additional loop. 

 

1

 

zz  

 

c.  Serial Number  - This prompt can be used to enroll the transmitter serial number via RF 

transmission or manually. If using RF Learning proceed to c. 1). If using the manual mode skip to 
c. 2). 

 

1) 

RF Learning - 

Two (2) transmissions (two key depressions at least five second apart) will be 

required for BR type or four (4) transmissions (fault, restore and fault, restore) for UR or RF 
type. BR type devices can be enrolled only by transmission from BR devices. Likewise, UR 
and RF devices can only be enrolled by transmission from a UR or RF device.  
If the learned serial number has a different loop number than that entered in *56  the system 
will announce the Voice Descriptor, if it is programmed, followed by two beeps and

 

will return 

to Prompt (1A) and “L” will be displayed. 

 

 If the loop number captured by RF transmission and that entered in *56 mode match, the 
system will announce the Voice Descriptor, if it is programmed, followed by three beeps and 
return to Prompt (1A) and “LC” will be displayed.  No additional transmissions are needed for 
confirmation. 

Note: 

BR type devices can be enrolled only by transmission from BR devices. Likewise, UR and RF devices 
can only be enrolled by transmission from a UR or RF device. 

1

b

      

 

2)  Manual Entry -

 

Enter the 7-digit serial number printed on the transmitter. If you enter an 

incorrect digit, press the [#] key to backup to prompt (1A) and start over. When all seven 
digits are entered press the [*] key. 

 

 

- 4 -

Содержание ReadyGuard-RI

Страница 1: ...rm response 30 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away 31 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm 32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4...

Страница 2: ...10145X10 transformer to terminals 9 13 and 14 respectively Note Install Powerline Carrier Devices according to their instructions f Connect wires from the K10145X10 K101450CN AC Transformer to termina...

Страница 3: ...Enter Programming mode Installer Code 8 0 0 b Press 97 then press a number 1 4 to select a default table from the tables listed on page 1 2 Program the variable data fields as follows a RF House ID Pr...

Страница 4: ...mber transmission has been confirmed to match No further transmissions will be received Note When confirming a 4 button key it assumed that all loops are used and only the serial number is confirmed P...

Страница 5: ...ller Code OFF 8 Assign desired User Codes by following the procedures in the User Guide Show the user how to perform the various system functions 9 Perform site initiated downloader session to load ce...

Страница 6: ...t message playback system announcement volume FUNCTION VOLUME 3 Up or 6 Down To mute system announcements FUNCTION VOLUME OFF To restore unmute announcements volume FUNCTION VOLUME 3 or 6 Note If the...

Страница 7: ...9 Speaker Phone Operation Note The ARMED and READY LEDs blink alternately when the Speaker Phone feature is active To place a call or answer a call using the speaker phone AUX To Flash switch between...

Страница 8: ...K14117 1E K14117 1 4 06 Rev A 149 Eileen Way Syosset NY 11791 Copyright 2006 Honeywell International Inc www firstalertprofessional com...