First Alert ReadyGuard-RI Скачать руководство пользователя страница 1

K14117-1     4/06  Rev. A 

 

ReadyGuard-RI 

Security Systems

 

 

 

Quick Start Guide  

 

U

U

U

ULLLL    

ReadyGuard-RI is not intended for UL985 Household Fire applications unless a 24-hour backup battery  
(P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.

 

 

Introduction 

This Quick Start Guide can help you install the rechargeable ReadyGuard-RI quickly and easily by providing the 
basic steps for installation using the built-in defaults.  For more detailed information and important notes, refer to 
the ReadyGuard-RI Installation and Setup Guide. 

 

The following steps assume that one of the system’s default tables will be used.  

For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the 
Installation Instructions. 

 

Default Table Summary 

Zone

 

Table 1

 

Table 2

 

Table 3

 

Table 4

 

2

 

front door

 

front door

 

front door

 

front door

 

3

 

back door

 

back door

 

back door

 

back door

 

4

 

window

 

garage door

 

window

 

window

 

5

 

motion detector

 

motion detector

 

window

 

window

 

6

 

-------

 

smoke detector

 

window

 

window

 

7

 

-------

 

-------

 

window

 

window

 

8

 

-------

 

-------

 

motion detector

 

motion detector

 

9

 

-------

 

-------

 

smoke detector

 

smoke detector

 

26

 

loop 3 arm away

 

loop 3 arm away

 

loop 3 arm away

 

loop 3 arm away

 

27

 

loop 2 disarm

 

loop 2 disarm

 

loop 2 disarm

 

loop 2 disarm

 

28

 

loop 4 arm stay

 

loop 4 arm stay

 

loop 4 close device

 

loop 4 close device

 

29

 

loop 1 no alarm response

 

loop 1 no alarm response

 

loop 1 no alarm response

 

loop 1 no alarm response

 

30

 

loop 3 arm away

 

loop 3 arm away

 

loop 3 arm away

 

loop 3 arm away

 

31

 

loop 2 disarm

 

loop 2 disarm

 

loop 2 disarm

 

loop 2 disarm

 

32

 

loop 4 arm stay

 

loop 4 arm stay

 

loop 4 close device

 

loop 4 close device

 

33

 

loop 1 no alarm response

 

loop 1 no alarm response

 

loop 1 no alarm response

 

loop 1 no alarm response

 

92

 

duress

 

duress

 

duress

 

duress

 

99

 

silent alarm

 

audible alarm

 

silent alarm

 

silent alarm

 

Master User Code

 

1-2-3-4

 

1-2-3-4

 

1-2-3-4

 

1-2-3-4

 

Installer Code

 

4-1-1-2

 

4-1-1-2

 

4-1-1-2

 

4-1-1-2

 

Duress Code

 

------

 

------

 

------

 

------ 

 

Entering Expert Program Mode: 

installer code + 8 0 0

 

 

Interactive Mode 

Used to Program 

*56

 Enhanced Zone Programming 

Zone characteristics, report codes, and serial numbers 

*83

 Enhanced Sequential Mode 

5800 Series transmitter serial numbers 

*84

 Assign Zone Voice Descriptors 

Voice descriptors for each zone 

 

Exiting Program Mode:

 *

98 

inhibits re-entry into the Programming mode using the Installer Code.  

 

*

99

 allows re-entry into the Program mode using Installer Code + 8  0  0.

 

 

 

 

NOTES:

 

  Table 4 supports the automatic paging feature (open/close events reported to pager phone number),and a Powerline Carrier Device programmed 

as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a 
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions. 

  Primary and secondary report format for all tables is Ademco’s Contact ID® reporting.  

  Tables 1, 3 and 4 record only alarms, alarm restores, troubles, and trouble restores in the event log. Table 2 records all events in the event log. 

 

 

 

Содержание ReadyGuard-RI

Страница 1: ...rm response 30 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away 31 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm 32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4...

Страница 2: ...10145X10 transformer to terminals 9 13 and 14 respectively Note Install Powerline Carrier Devices according to their instructions f Connect wires from the K10145X10 K101450CN AC Transformer to termina...

Страница 3: ...Enter Programming mode Installer Code 8 0 0 b Press 97 then press a number 1 4 to select a default table from the tables listed on page 1 2 Program the variable data fields as follows a RF House ID Pr...

Страница 4: ...mber transmission has been confirmed to match No further transmissions will be received Note When confirming a 4 button key it assumed that all loops are used and only the serial number is confirmed P...

Страница 5: ...ller Code OFF 8 Assign desired User Codes by following the procedures in the User Guide Show the user how to perform the various system functions 9 Perform site initiated downloader session to load ce...

Страница 6: ...t message playback system announcement volume FUNCTION VOLUME 3 Up or 6 Down To mute system announcements FUNCTION VOLUME OFF To restore unmute announcements volume FUNCTION VOLUME 3 or 6 Note If the...

Страница 7: ...9 Speaker Phone Operation Note The ARMED and READY LEDs blink alternately when the Speaker Phone feature is active To place a call or answer a call using the speaker phone AUX To Flash switch between...

Страница 8: ...K14117 1E K14117 1 4 06 Rev A 149 Eileen Way Syosset NY 11791 Copyright 2006 Honeywell International Inc www firstalertprofessional com...

Отзывы: