K14117-1 4/06 Rev. A
ReadyGuard-RI
Security Systems
Quick Start Guide
U
U
U
ULLLL
ReadyGuard-RI is not intended for UL985 Household Fire applications unless a 24-hour backup battery
(P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable ReadyGuard-RI quickly and easily by providing the
basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to
the ReadyGuard-RI Installation and Setup Guide.
The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.
Default Table Summary
Zone
Table 1
Table 2
Table 3
Table 4
2
front door
front door
front door
front door
3
back door
back door
back door
back door
4
window
garage door
window
window
5
motion detector
motion detector
window
window
6
-------
smoke detector
window
window
7
-------
-------
window
window
8
-------
-------
motion detector
motion detector
9
-------
-------
smoke detector
smoke detector
26
loop 3 arm away
loop 3 arm away
loop 3 arm away
loop 3 arm away
27
loop 2 disarm
loop 2 disarm
loop 2 disarm
loop 2 disarm
28
loop 4 arm stay
loop 4 arm stay
loop 4 close device
loop 4 close device
29
loop 1 no alarm response
loop 1 no alarm response
loop 1 no alarm response
loop 1 no alarm response
30
loop 3 arm away
loop 3 arm away
loop 3 arm away
loop 3 arm away
31
loop 2 disarm
loop 2 disarm
loop 2 disarm
loop 2 disarm
32
loop 4 arm stay
loop 4 arm stay
loop 4 close device
loop 4 close device
33
loop 1 no alarm response
loop 1 no alarm response
loop 1 no alarm response
loop 1 no alarm response
92
duress
duress
duress
duress
99
silent alarm
audible alarm
silent alarm
silent alarm
Master User Code
1-2-3-4
1-2-3-4
1-2-3-4
1-2-3-4
Installer Code
4-1-1-2
4-1-1-2
4-1-1-2
4-1-1-2
Duress Code
------
------
------
------
Entering Expert Program Mode:
installer code + 8 0 0
Interactive Mode
Used to Program
*56
Enhanced Zone Programming
Zone characteristics, report codes, and serial numbers
*83
Enhanced Sequential Mode
5800 Series transmitter serial numbers
*84
Assign Zone Voice Descriptors
Voice descriptors for each zone
Exiting Program Mode:
*
98
inhibits re-entry into the Programming mode using the Installer Code.
*
99
allows re-entry into the Program mode using Installer Code + 8 0 0.
NOTES:
•
Table 4 supports the automatic paging feature (open/close events reported to pager phone number),and a Powerline Carrier Device programmed
as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions.
•
Primary and secondary report format for all tables is Ademco’s Contact ID® reporting.
•
Tables 1, 3 and 4 record only alarms, alarm restores, troubles, and trouble restores in the event log. Table 2 records all events in the event log.