WIRING TABLE 

Keypad

 

Control Panel

 

Wire Color 

G

 

Data In

 

Green 

 

 Aux Pwr (GND)

 

Black 

+

 

+ Aux Pwr

 

Red 

Y

 

Data Out

 

Yellow 

Note: 

NO (normally Open) and C (common) are the 

connections for the relay output 

+

FA270RF-005-V0

NO C

Y

G

 

Figure 2 - FA270RF Wiring Connections

 

 

APPLICATION GUIDELINES  

Use the following guidelines when planning an installation: 

 

Local wireless keys (wireless keys programmed directly into the FA270RF) may be used regardless of whether the 
RF receiver in the FA270RF is enabled or disabled. 

 

If using bi-directional devices, be sure to enable the transmitter module in the FA270RF. 

 

If transmitters are programmed into the control panel, be sure to enable the receiver. (Make sure you do not 
exceed the number of receivers supported by the control panel.) 

 

If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code must be 
entered into the FA270RF. This user code must also be programmed into the control panel. 

 

You must set the House ID in the FA270RF (If the House ID source is “System”, the FA270RF uses the House ID 
programmed in the Control Panel.) only if you are using RF keypads and/or bi-directional devices; 

AND

 the House 

ID Source is the FA270RF (Local).

 

FA270RF Application Guide 

The following guide outlines how to program the wireless keys, RF receiver, and the House ID in the FA270RF for 
your installation. 

*  Two FA270RFs are needed for this application: one assigned to partition 1 and one assigned to partition 2. 

**  If using an RF keypad on only one partition, the FA270RF’s partition assignment in panel programming must match the partition. 

*** If set for Local on a partition control, the FA270RF’s partition assignment must match the one programmed in the BD device.

 

Are you using

 

FA270RF Programming Options 

System Control Panel

 

RF keys 

beyond 

system’s 

capacity?

 

RF receivers 

beyond 

system’s 

capacity?

 

RF keypads and/or 

Bi-directional 

devices on more 

than 1 partition?

 

Program 

Wireless Keys 

Into

 

Receiver 

Enable

 

House ID 

Source

***

 

FA110C, FA120C

 

N/A

 

N/A

 

N/A

 

FA270RF

 

OFF 

 

Local [0] 

NO

 

NO

 

N/A

 

System

 

ON [1]

 

System [1] 

YES

 

NO

 

N/A

 

FA270RF

 

ON [1]

 

System [1] 

FA142C, FA148C, FA148CP

 

YES

 

YES

 

N/A

 

FA270RF

 

OFF [0]

 

Local [0] 

NO

 

NO

 

NO

 

System

 

ON [1]

 

System [1] 

YES

 

NO

 

NO

 

FA270RF

 

ON [1]

 

System [1] 

YES

 

YES

 

NO

 

FA270RF

 

OFF [0]

 

Local [0] 

NO

 

YES

 

YES*

 

System

 

OFF [0]

 

Local [0] 

FA162C, FA168C, FA168CPS

 

YES

 

YES

 

YES*

 

FA270RF

 

OFF [0]

 

Local [0] 

NO

 

NO

 

NO**

 

System

 

ON [1]

 

System [1] 

YES

 

NO

 

NO**

 

FA270RF

 

ON [1]

 

System [1] 

YES

 

YES

 

NO**

 

FA270RF

 

OFF [0]

 

Local [0] 

NO

 

YES

 

YES

 

System

 

OFF [0]

 

Local [0] 

FA1220CV, FA1340C

 

YES

 

YES

 

YES

 

FA270RF

 

OFF [0]

 

Local [0] 

Содержание FA270RF

Страница 1: ...erates the on board relay in conjunction with the receiver e g to trip a garage door opener U U U UL L L L This feature is not intended for UL installations Activates relays programmed into the control panel Provides an End User mode to enable disable local wireless keys e g if a user accidentally loses a wireless key Refer to the FA270RF User Guide for this procedure INSTALLING THE FA270RF Locate...

Страница 2: ...ices AND the House ID Source is the FA270RF Local FA270RF Application Guide The following guide outlines how to program the wireless keys RF receiver and the House ID in the FA270RF for your installation Two FA270RFs are needed for this application one assigned to partition 1 and one assigned to partition 2 If using an RF keypad on only one partition the FA270RF s partition assignment in panel pro...

Страница 3: ...r instructions Programming Operations Once you have entered the Program mode you may move to any program address simply by entering the program address number The FA270RF will automatically exit the Program mode if no keys are pressed for 90 seconds While in the Program mode Pressing the key stores the information displayed then moves you to the next prompt and the keypad beeps twice Pressing the ...

Страница 4: ...steps Step Action Display 1 Enter the Program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after removing the case back Alternately flashes oo and two dashes 2 Enter 1 Keypad Address Enter the 2 digit keypad address 01 31 Press the key to continue Alternately flashes cA and the 2 digit keypad address 3 Enter 2 Receiv...

Страница 5: ...al number The keypad will beep three times Note If enrolling a wireless key 5804E in high security mode press all four buttons on the wireless key simultaneously Alternately flashes d with the device number and the serial number 4 Press the key to accept the serial number OR press the key to reject the serial number If you accept the serial number the FA270RF beeps two times If you reject the seri...

Страница 6: ...mber and the relay action 10 Repeat step 9 for the rest of the loops 11 When all loops have been programmed for the wireless key press the key Flashes d followed by the device number 12 The FA270RF automatically displays the next available device number one that does not have a serial number If you want to program additional wireless keys repeat steps 3 through 10 Otherwise press the key This take...

Страница 7: ...tions Display Probable Cause Corrective Action Lb Low battery in a wireless key 1 Replace the battery in the wireless key 2 Replace the transmitter if the wireless key does not have a replaceable battery OC Open circuit Verify that the Data Out wire is connected properly 1C Incompatible connection Verify that the control panel is not a First Alert type control panel Check 09 OR Check 100 OR Check ...

Страница 8: ...r 24 months from the date stamp control on the product s or for product s not having a manufacturer s date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any pr...

Отзывы: