- 2 -
WIRING TABLE
Keypad
Control Panel
Wire Color
▲
G
Data In
Green
−
−
Aux Pwr (GND)
Black
+
+ Aux Pwr
Red
▼
Y
Data Out
Yellow
Note:
NO (normally Open) and C (common) are the
connections for the relay output
+
FA270RF-005-V0
NO C
Y
G
Figure 2 - FA270RF Wiring Connections
APPLICATION GUIDELINES
Use the following guidelines when planning an installation:
•
Local wireless keys (wireless keys programmed directly into the FA270RF) may be used regardless of whether the
RF receiver in the FA270RF is enabled or disabled.
•
If using bi-directional devices, be sure to enable the transmitter module in the FA270RF.
•
If transmitters are programmed into the control panel, be sure to enable the receiver. (Make sure you do not
exceed the number of receivers supported by the control panel.)
•
If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code must be
entered into the FA270RF. This user code must also be programmed into the control panel.
•
You must set the House ID in the FA270RF (If the House ID source is “System”, the FA270RF uses the House ID
programmed in the Control Panel.) only if you are using RF keypads and/or bi-directional devices;
AND
the House
ID Source is the FA270RF (Local).
FA270RF Application Guide
The following guide outlines how to program the wireless keys, RF receiver, and the House ID in the FA270RF for
your installation.
* Two FA270RFs are needed for this application: one assigned to partition 1 and one assigned to partition 2.
** If using an RF keypad on only one partition, the FA270RF’s partition assignment in panel programming must match the partition.
*** If set for Local on a partition control, the FA270RF’s partition assignment must match the one programmed in the BD device.
Are you using
FA270RF Programming Options
System Control Panel
RF keys
beyond
system’s
capacity?
RF receivers
beyond
system’s
capacity?
RF keypads and/or
Bi-directional
devices on more
than 1 partition?
Program
Wireless Keys
Into
Receiver
Enable
House ID
Source
***
FA110C, FA120C
N/A
N/A
N/A
FA270RF
OFF
Local [0]
NO
NO
N/A
System
ON [1]
System [1]
YES
NO
N/A
FA270RF
ON [1]
System [1]
FA142C, FA148C, FA148CP
YES
YES
N/A
FA270RF
OFF [0]
Local [0]
NO
NO
NO
System
ON [1]
System [1]
YES
NO
NO
FA270RF
ON [1]
System [1]
YES
YES
NO
FA270RF
OFF [0]
Local [0]
NO
YES
YES*
System
OFF [0]
Local [0]
FA162C, FA168C, FA168CPS
YES
YES
YES*
FA270RF
OFF [0]
Local [0]
NO
NO
NO**
System
ON [1]
System [1]
YES
NO
NO**
FA270RF
ON [1]
System [1]
YES
YES
NO**
FA270RF
OFF [0]
Local [0]
NO
YES
YES
System
OFF [0]
Local [0]
FA1220CV, FA1340C
YES
YES
YES
FA270RF
OFF [0]
Local [0]