)$& ,QVWDOODWLRQ DQG 6HWXS *XLGH
+
WEEKLY TESTING IS REQUIRED
TO ENSURE PROPER OPERATION
OF THIS SYSTEM.
POLE Door Strike/Mag Coil
DATA 1 (WHITE)
DATA 0 (GREEN)
NOTE 1: USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS.
NOTE 2: VISTAKEY TB3 TERMINAL 5 IS A GROUND AND MAY BE
USED INSTEAD OF TB3 TERMINAL 2. TB3 TERMINALS 2 AND 5 ARE
A COMMON GROUND.
NOTE 3: WHEN USING TRIGGER TO TURN ON AN LED OR BUZZER,
RETURN HIGH SIDE OF LED OR BUZZER TO TB3 TERMINAL 7.
TRIGGER RATING IS 15mA AT 12VDC.
+5V
GND
TRIGGER (SEE NOTE 3)
+12V (RED)
ZONE C (General)
ZONE A (DSM)
ZONE B (RTE)
POLLING LOOP -
14V MAX (12V @ 85-160mA Nominal)
POLLING LOOP +
GND
GND
GND
N/O DOOR STRIKE POWER
N/C MAG COIL POWER
2
3
4
5
6
7
8
11 12
2 3 4 5 6 7 8 9 10
1
RELAY CONTACT RATINGS:
3A @ 28VDC MAX. (RESISTIVE LOAD)
TB 1
TB 3
1
READER INTERFACE CABLE
GND (BLACK)
RDR LED (ORANGE)
TO ALARM SYSTEM
CONTROL PANEL
POLLING LOOP TERMINALS.
NO
CONNECTION
VISTAKEY
THIS DEVICE COMPLIES WITH PART 15 CLASS A
LIMITS OF FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS:
(1) IT MAY NOT CAUSE HARMFUL INTERFERENCE.
(2) IT MUST ACCEPT ANY INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
K1
DOOR
CONTROL
RELAY
FOR ADDITIONAL RATINGS AND
SPECIFICATIONS, REFER TO
INSTALLATION INSTRUCTION
FOR THE VISTAKEY-SK.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION'S STANDARDS 70 &
74 (NATIONAL FIRE PROTECTION ASSOC.,
BATTERYMARCH PARK, QUINCY, MA. 02269).
PRINTED INFORMATION DESCRIBING PROPER
MAINTENANCE, EVACUATION PLANNING AND
REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.
TO TB1, 11 OR 12
+ 12 VDC TO ONLY
ONE OF THESE INPUTS.
(FROM TB1-1)
)LJXUH :LULQJ WKH 9LVWD.H\
$FFHVV&RQWURO8VLQJWKH3DVV3RLQW$FFHVV&RQWURO6\VWHP
7KH )$& LQWHUIDFHV ZLWK WKH 3DVV3RLQW $&6 YLD
WKH 9,67$ *DWHZD\ 0RGXOH 9*0 7KH 9*0 LV
FRQQHFWHG EHWZHHQ WKH (&3 EXV NH\SDG WHUPLQDOV RI
WKH FRQWURO DQG WKH QHWZRUN EXV RI WKH 3DVV3RLQW $&6
7KH FRQWURO VHQGV WKH 9*0 LWV VWDWXV LQIRUPDWLRQ
HYHQW ORJ HQWULHV DQG HQWU\H[LW UHTXHVWV LQSXWV
SURJUDPPHG ZLWK UHVSRQVH W\SH $FFHVV 3RLQW IURP
NH\SDGV KDUGZLUHG ]RQHV DQG 5) WUDQVPLWWHUV 7KH
9*0 WKHQ UHIRUPDWV DQG UHWUDQVPLWV WKLV LQIRUPDWLRQ
WR WKH 0DLQ /RJLF %RDUG 0/% RQ WKH 3DVV3RLQW $&6
QHWZRUN EXV
8/
,QWHUIDFLQJ WKH )$& ZLWK WKH 3DVV3RLQW
$FFHVV &RQWURO 6\VWHP YLD WKH 9,67$ *DWHZD\
0RGXOH LV QRW SHUPLVVLEOH IRU 8/ LQVWDOODWLRQV
:LULQJ WKH 9,67$ *DWHZD\ 0RGXOH
7KH 9,67$ *DWHZD\ 0RGXOH LV FRQQHFWHG EHWZHHQ WKH
(&3 EXV )$& NH\SDG WHUPLQDOV DQG WKH QHWZRUN
EXV RI WKH 3DVV3RLQW $FFHVV &RQWURO 6\VWHP 6HH
)LJXUH IRU WKH SURSHU ZLULQJ FRQQHFWLRQV
}
ECHELON NETWORK
(PASSPOINT ACS)
YELLOW
RED
BLACK
PROM C
TRANSFORMER
4-PIN
KEYPAD
PLUG
}
TO
CONTROL’S
KEYPAD
TERMINALS
GREEN
)LJXUH :LULQJ WKH 9,67$ *DWHZD\ 0RGXOH
(YHQW/RJ&RQQHFWLRQV
7KLV V\VWHP KDV WKH DELOLW\ WR UHFRUG XS WR HYHQWV RI
YDULRXV FDWHJRULHV LQ WKH (YHQW /RJ KLVWRU\ ORJ (DFK
HYHQW LV UHFRUGHG ZLWK WKH WLPH DQG GDWH RI LWV
RFFXUUHQFH LI UHDOWLPH FORFN LV VHW 7KH FDWHJRULHV DUH
$ODUP 6XSHUYLVRU\&KHFN %\SDVV 2SHQ&ORVH DQG
6\VWHP FRQGLWLRQV
7KH ORJ PD\ EH YLHZHG RQ DQ DOSKD NH\SDG RU SULQWHG
RQ D SDUDOOHO RU VHULDO SULQWHU
127( ,I \RX DUH XVLQJ D SDUDOOHO SULQWHU \RX PXVW XVH
WKH 9$ $OSKD 3DJHU 0RGXOH
Содержание FA1660C
Страница 2: ... ...
Страница 18: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Страница 76: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Страница 98: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Страница 114: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Страница 118: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Страница 128: ... 4l LOHHQ D 6 RVVHW 1 KWWS ILUVWDOHUWSUR FRP RS ULJKW 3 77 25325 7 21 ...