FA147C Installation Instructions

1Ð2

Programming

¥ Programmed options are stored in electrically erasable, non-volatile EEROM memory

(information can be reprogrammed at any time and will not be lost in the event of a power
loss).

¥ Upon exiting the programming mode after programming at the system site, all programmed

data is automatically uploaded to the central station; if the upload was successful, a message
to that effect will be displayed at the keypads.

For programming from a keypad, an FA550KP

 

2-line Alpha keypad must be connected (but need

not necessarily stay in the system).

Security Codes

¥ One Master code for entire system (user 2).  Installer code is user 1.

¥ Up to 5 secondary user codes (for users 3Ð7). If 

not 

using a Duress code, user code 8 is

available for an additional user.

¥ One duress code (user 8) which, when used to disarm or arm the system, will send a silent

duress message to the central station.

Keypad Panic Keys

¥ Up to 3 programmable panic key functions are provided, designated as Zones 95, 96 and 99.

¥ Activated by wired and wireless keypads.

Paging Feature

If the paging feature has been programmed for your system, a pager will respond to certain
conditions as they occur in your system, and display code numbers on the pager indicating the
type of condition that has occurred.

Quick Arm Feature

ÒQuick ArmÓ may be programmed , allowing use of the [#] key in place of the security code for
arming (Quick Arm will not work unless the Master code has been programmed into the
system).

Optional Output Relays

¥ Up to 4 relays using one  Ademco 

4204  Relay Module

¥ Up to 2 relays using one  Ademco 

4229  Zone Expansion/Relay Module

¥ Actions programmable to respond to zone activity or manual keypad entries

Optional Phone Module

¥ Supports the

 FA4285 Phone Module

.

¥ Provides access to the system via on premises or off-premises phones for arming, disarming,

etc., plus control of relay outputs.

Optional Long Range Radio

¥ Allows all messages that have been programmed to go to the primary telephone number to

be reported additionally to an  Ademco 

7720 PLUS

 or 

7820 

radio.

Alarm Output

¥

Provides a 12VDC, 2 AMP output that can drive the compatible sounders listed in the

External Sounders

 section (assumes a fully charged battery is connected).

¥ Steady output for Burglary/Panic, or temporal pulse sounding output for Fire notification, as

required by UL.

¥ Uses current limiting circuitry for protection.
¥ Provision for Bell supervision.

Содержание FA147C

Страница 1: ...K3211 3 98 INSTALLATION INSTRUCTIONS FA147C Security System...

Страница 2: ...alarm in the hallway outside may not wake up the sleeper if the door is closed Install a smoke detector inside bedrooms where electrical appliances such as portable heaters air conditioners or humidif...

Страница 3: ...n Characteristics For Zones 1 6 4 1 Wiring Burglary and Panic Devices to Zones 1 6 4 1 Wiring 4 Wire Smoke Combustion Detectors 4 1 Compatible 4 Wire Smoke Combustion Detectors 4 2 Programming Hard Wi...

Страница 4: ...me By Zone 7 10 Section 8 FA4285 Phone Module 8 1 Mounting the FA4285 Phone Module 8 1 General Information 8 1 Phone Module Wiring 8 2 Caller ID Units 8 2 Programming The Control For Phone Access 8 4...

Страница 5: ...Master Code 17 1 Changing the Master Code 17 1 User Codes 17 1 Duress Code 17 2 Keypad Functions 17 2 General Information 17 2 Arming Disarming Functions etc 17 3 Panic Keys 17 3 FA4285 Phone Module i...

Страница 6: ...Detector Connections 4 2 Figure 5 1 Wiring Connections 4219 and 4229 5 1 Figure 6 1 5881 and 5882 Wireless Receivers cover removed 6 3 Figure 7 1 4204 Connections To Control 7 2 Figure 7 2 4229 Conne...

Страница 7: ...ding Wireless zones adding an FA4285 Phone Module etc Without an understanding of the programming method for this system you will not be able to successfully perform the required programming Before an...

Страница 8: ...not observed could seriously affect the operation of the system or could cause damage to the system Please read each warning carefully This symbol also denotes warnings about physical harm to the ins...

Страница 9: ...ones up to 30 total wired and wireless zones Wired Expansion Supports up to 8 additional wired zones using a 4219 expansion module or 4229 expansion relay module Zones will have the following characte...

Страница 10: ...mmed for your system a pager will respond to certain conditions as they occur in your system and display code numbers on the pager indicating the type of condition that has occurred Quick Arm Feature...

Страница 11: ...Bell Supervision Red jumper on control board when cut will provide supervision of bell wiring when bell is wired with EOL resistor as indicated in the instructions Auxiliary Power Output Provides 12V...

Страница 12: ...FA147C Installation Instructions 1 4...

Страница 13: ...ge and or block RF transmissions from wireless transmitters Do not locate the cabinet in an area of high RF interference revealed by frequent or pro longed lighting of the LED in the receiver after it...

Страница 14: ...be used on the circuit board even when the RF receiver is mounted above it Installing the 4204 4219 or 4229 Module in the Cabinet See Figure 2 2 Any one of these units can be mounted in the cabinet wi...

Страница 15: ...ee Detail B in Fig 2 3 4 Insert the top of the control s board into the slot in the clips and position two long red clips at the lower edge of the board see Detail C 5 Swing this board into place and...

Страница 16: ...onnect Cord TERMINALS ON CONTROL EARTH GROUND PREMISES PHONES Handset Incoming Telco Line TIP RING BROWN TIP GRAY RING GREEN TIP RED RING RJ31X JACK PLUG DIRECT CONNECT CORD TIP RING GROUND INCOMING T...

Страница 17: ...til you are instructed to do so later in the manual Earth Ground Connections This product has been designed and laboratory tested to ensure its resistance to damage from generally expected levels of l...

Страница 18: ...FA147C Installation Instructions 2 6...

Страница 19: ...o The Keypads 1 Determine wire gauge by referring to the wiring length gauge chart below For devices Keypads RF Receivers Expansion Relay units etc connected to a single 4 wire run determine the curre...

Страница 20: ...address setting procedure 2 Mount the keypads at a height that is convenient for the user Refer to the instructions provided with the keypad for mounting procedure You can either surface mount or flus...

Отзывы: