FA147C Installation Instructions
1Ð2
Programming
¥ Programmed options are stored in electrically erasable, non-volatile EEROM memory
(information can be reprogrammed at any time and will not be lost in the event of a power
loss).
¥ Upon exiting the programming mode after programming at the system site, all programmed
data is automatically uploaded to the central station; if the upload was successful, a message
to that effect will be displayed at the keypads.
For programming from a keypad, an FA550KP
2-line Alpha keypad must be connected (but need
not necessarily stay in the system).
Security Codes
¥ One Master code for entire system (user 2). Installer code is user 1.
¥ Up to 5 secondary user codes (for users 3Ð7). If
not
using a Duress code, user code 8 is
available for an additional user.
¥ One duress code (user 8) which, when used to disarm or arm the system, will send a silent
duress message to the central station.
Keypad Panic Keys
¥ Up to 3 programmable panic key functions are provided, designated as Zones 95, 96 and 99.
¥ Activated by wired and wireless keypads.
Paging Feature
If the paging feature has been programmed for your system, a pager will respond to certain
conditions as they occur in your system, and display code numbers on the pager indicating the
type of condition that has occurred.
Quick Arm Feature
ÒQuick ArmÓ may be programmed , allowing use of the [#] key in place of the security code for
arming (Quick Arm will not work unless the Master code has been programmed into the
system).
Optional Output Relays
¥ Up to 4 relays using one Ademco
4204 Relay Module
¥ Up to 2 relays using one Ademco
4229 Zone Expansion/Relay Module
¥ Actions programmable to respond to zone activity or manual keypad entries
Optional Phone Module
¥ Supports the
FA4285 Phone Module
.
¥ Provides access to the system via on premises or off-premises phones for arming, disarming,
etc., plus control of relay outputs.
Optional Long Range Radio
¥ Allows all messages that have been programmed to go to the primary telephone number to
be reported additionally to an Ademco
7720 PLUS
or
7820
radio.
Alarm Output
¥
Provides a 12VDC, 2 AMP output that can drive the compatible sounders listed in the
External Sounders
section (assumes a fully charged battery is connected).
¥ Steady output for Burglary/Panic, or temporal pulse sounding output for Fire notification, as
required by UL.
¥ Uses current limiting circuitry for protection.
¥ Provision for Bell supervision.