Current Consumption
Page 13 / 27
8 Current Consumption
STATUS
Current Consumption (mA)
MIN
MAX
AVG
Standby
18
24
22
Inquiry scan & page scan (Slave)
21
63
42
Page scan (Slave)
18
30
23
Inquiry (Master)
77
83
80
Connected
Slave
36
45
41
Master
21
33
27
Data transmission
Slave
48
54
51
Master
48
57
52
Data reception
Slave
45
51
48
Master
45
54
49
Data transmission / reception
Slave
48
57
52
Master
51
60
56
Power save
Slave
21
30
24
Master
21
33
24
<Table 8-1 Current Consumption of FB200AS-F>
TEST CONDITIONS
Baud rate : 9600 bps, Input Voltage : DC 5V
The power consumption is subject to change depending on the transmission rate and volume of data.