SPECIFICATIONS

Model

Starting Watts

 

 

Running Watts

Rated AC Voltage

Rated

Phase

Voltage Regulator

Total Harmonic Distortion(THD)

Power Factor

Alternator

 

Type

Engine

Engine Type

Displacement

Low Oil Shutdown

Ignition System

Starting System

Fuel

Capacity Fuel Tank

Lubricating Oil Capacity

Carburetor

 

Type

Air

 

Cleaner

P.T.O. Shaft Rotation

Oil Type

AC Grounding System

Gross/Net Weight

Height

×

W

idth

×

Length

 

Fequency

 

 

 

 

 

 

 

R-

H07552

9400(GASOLINE)/8450(LPG)

7500(GASOLINE)/6750(LPG)

1

Single Cylinder, 4-Stroke OHV Air Cooled

37.2 oz(1.1L)

120/240V

60Hz

Single

AVR

Standard

Brushed

439cc

Yes

Breakless Ignition Type, Flywheel Magneto

Unleaded 

Automotive

 Gasoline/LPG

8.0 Gallon

Float

Polyurethane Type

Counter Clockwise (Facing P.T.O.)

See “Add Engine Oil” Section

Neutral Bonded To Frame

 

FIRMAN

Recoil/Electric Start

AN IMPORTANT MESSAGE ABOUT TEMPERATURE:

When operated above 77°F(25°C) there may be a decrease in power.
Maximum wattage and current are subject to and limited by such factors as fuel BTU content
ambient temperature, altitude, engine condition and etc. Maximum power decreases about
3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 10°F(6

°C

)

above 60°F(16

°C

) ambient temperature.

••

English

             

26.2 27 5 30 1

66.8 69.9 76.6(cm)

×

. ×

. (

in.

)/

×

×

227 lb.(103kg)/210 lb.(95.2kg)

Содержание R-H07551

Страница 1: ...ing equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage OWNER S MANUAL DUAL FUEL GENERATOR REMANUFACTURED ARC LP NO Purchase Date MODEL NUMBER R H07551 ...

Страница 2: ... to a Building s Electrical Maintenance And Storage 27 Maintenance Schedule 27 Engine Maintenance 28 Change Engine Oil 28 Air Filter Maintenance 28 Spark Plug Maintenance 29 Cleaning Fuel Strainer 29 29 Generator Maintenance 30 30 Service and Storage 31 Trouble Shooting 33 Parts Diagram and Parts List 34 Generator Parts Diagram 34 Engine Parts Diagram 35 Parts List 36 Service Information 38 Warran...

Страница 3: ...ucts and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment Save these original instructions for future refer...

Страница 4: ...oduct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoning Avoid other generator hazards READ MANUAL BEFORE USE WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer bir...

Страница 5: ...ide and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Basement Crawl Space Living Area Attic Entry Way Porch Mudroom English Support support arcaugusta com ...

Страница 6: ...hand and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive which could c...

Страница 7: ...l loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Страница 8: ...e Gasoline can cause a fire or explosion if ignited Gasoline is a liquid fuel but it s vapors can ignite Gasoline is a skin irritant and needs to be cleaned up immediately if spilled on skin or clothes Gasoline has a distinctive odor this will help detect potential leaks quickly In any gasoline fire flames should not be extinguished unless by doing so the fuel supply valve can be turned OFF This i...

Страница 9: ...nited LPG is heavier than air and can accumulate in confined spaces and low places in the event of a leak LPG has a distinctive odor to help detect potential leaks Do not allow children to tamper or play with the LPG cylinder In the event of an LPG fire flames should not be extinguished unless by doing so the fuel supply valve can be turned off If the fire is extinguished and a supply of fuel is n...

Страница 10: ...the axle pin A through the wheel B 3 Slide the axle pin A through the mount point on the frame and flat washer D 4 Secure the wheel and axle pin with the cotter pin C 5 Repeat steps 2 4 to attach another wheel 3 Tip the generator slowly so that it rests on the wheels and support leg 4 Tighten bolt E and nut F with provide wrenches CAUTION D 2 Attach the support leg G to the generator frame with fl...

Страница 11: ...ed 1 Verify the positive battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 2 Remove bolt M5X12 and M5 nut from black cable ring 3 Remove vinyl cap from the negative battery post Locate negative black cable and route to the negative battery post Tight the cable with bolt M5X12 and M5 nut Cover the post with black boot M5X12 M5 Black Cable ...

Страница 12: ...filter box 5 Air Filter 6 439cc FIRMAN OHV Engine 7 Recoil Starter 8 9 10 11 12 13 10 0 Flat Free Wheel Oil Filler Cap Battery Outlet Cover Control Panel Handle 14 LPG Hose Connector Inlet English We are always working to improve our products Therefore the enclosed product may differ slightly from the image on this page 2 ...

Страница 13: ...ANNOT BE STARTED DURING BATTERY POWER SAVING MODE UNLESS THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE GAS OR LPG POSITION See Indicator light Battery power Saving Mode section for more information 3 4 2 1 11 5 6 7 8 9 10 12 Ground Fault Circuit Interrupter conforms to UL 943 and NEC requirements This device protects you against hazardous electrical shock that ...

Страница 14: ...ctricity to prevent serious injury 1 Plug a test lamp into the receptacle 2 Start the generator the test lamp should be on 3 Press the Test button located on the front of the receptacle to trip the device 4 This should stop the flow of electricity making the lamp shut off The GFCI s indicator light comes off RESET TEST TEST MONTHLY FOLLOW DIRECTIONS RESET BUTTON Receptacle Outlet LED Indicator Lig...

Страница 15: ...V 60Hz Single AVR Standard Brushed 439cc Yes Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline LPG 8 0 Gallon Float Polyurethane Type Counter Clockwise Facing P T O See Add Engine Oil Section Neutral Bonded To Frame FIRMAN Recoil Electric Start AN IMPORTANT MESSAGE ABOUT TEMPERATURE When operated above 77 F 25 C there may be a decrease in power Maximum wattage and current are s...

Страница 16: ...te a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an even surface to correct this If engine fails to start the oil level may not be sufficient to deactivate low oil level switch Make sure the sump is completely full of oil H DRAIN PLUG L 5 Replace oil fill cap d...

Страница 17: ...fill cap remove cap 2 Slowly add unleaded fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or wipe up any spilled gasoline CAUTION Slowly add unleaded gasoline to fuel tank Do not overfill tank Do not fill above the red line indicator This will allow...

Страница 18: ... cylinder so the connection between the valve and the regulator won t cause bends or kinks in the hose Spray a soapy water solution one part liquid detergent and one part water to check all connections for leaks before attempting to use generator Slowly open the cylinder valve A leak exists if bubbles appear or grow larger in size or number This must be corrected before using the generator Contact...

Страница 19: ...also result due to the increased enrichment of the air fuel ratio Other high altitude issues can include hard starting increased fuel consumption and spark plug fouling To alleviate high altitude issues other than the natural power loss FIRMAN can provide a high altitude carburetor main jet The alternative The part number and recommended minimum altitude for the application of the high altitude ca...

Страница 20: ... a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or fe...

Страница 21: ...ther Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the proper functioning of sensitive electronic equipment WARNING POISONOUS GAS HAZARD Do not block generator air vents with paper or other material CAUTION Tilting can cause fuel spillage CAUTION English Page 19 Sup...

Страница 22: ...run at no load for few minutes upon each initial start up to permit engine and generator to stablize StartingtheGenerator RecoilStart LPG 1 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment 2 Check oil level NOTE When the fuel selector switch is turned to the GAS position the indicator light will become RED up to 4 minutes bef...

Страница 23: ... on engine to START position NOTE Do not place the LPG cylinder in the path of muffler outlet 9 Move the choke lever to the RUN position 11 Allow generator to run at no load for few minutes upon each initial start up to permit engine and generator to stablize 8 PULL TO PRIME Pull the starter cord 1 2 times Pull slowly until resistance if felt and then pull rapidly 10 PULL TO RUN Pull the starter c...

Страница 24: ...ctor switch is turned to the GAS position the indicator light will become RED up to 4 minutes before goes off Starting the engine successfully during these 4 minutes will turn the indicator light GREEN 5 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 6 Move choke lever located on engine to START position 7 Flip t...

Страница 25: ...TOR CANNOT BE STARTED DURING BATTERY POWER SAVING MODE UNLESS THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE LPG POSITION 9 Move the choke lever to the RUN position 4 Fully open the LPG cylinder knob 5 Turn the fuel selector switch to LPG position 9 Allow generator to run at no load for few minutes upon each initial start up to permit engine and generator to sta...

Страница 26: ...he generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during break in period the first five hours of operations working on nearby power lines If you plan to run a portable electric generator during an outage please notify your electric utility company immediately and remember to plug your appliances directly ...

Страница 27: ... STARTED DURING BATTERY POWER SAVING MODE UNLESS THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE GAS OR LPG POSITION Unwanted Shutdown The generator cannot be started during or after the 4 minutes of FLASHING mode unless the fuel selector switch is turned to the OFF position and then turned back to the GAS or LPG position for any unwanted shutdown This generator ...

Страница 28: ...sufficient fuel flow to the engine This is not an indication of a problem with the generator but only a problem with the flow of gas from the LPG cylinder If generator performance seems to be deteriorating at the same time that ice formation is observed on tank valve hose or regulator then some actions may be taken to eliminate this symptom In these rare situations it can be helpful to reduce or e...

Страница 29: ...ecommendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodical...

Страница 30: ...ancer in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine change oil after 25 hours DRAIN PLUG Please use a container to dump the used oil for protecting the environment b Reinstall the drain plug and fill the engine with oil until it...

Страница 31: ...arts Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a fire resulting in death or serious injury and or property Contact with muffler area could cause burns resulting in serious injury WARNING A B A Spark plug B Spark plug cap c DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on a...

Страница 32: ...h the screws Spark arrester screen Flange Screw Battery Replacement 1 Remove the spark plug wire from spark plug 2 Remove the nut and bolt from the negative and positive posts 3 Loosen and remove the screw A on the battery holding bracket 4 Remove the battery and recycle and dispose of properly 12V sealed lead acid 15AH LXWXH 180X75X165mm 7 09X2 95X6 5inch 6 Connect the red positive battery cable ...

Страница 33: ...om lack of gasoline This will dry out all remaining gasoline in tank fuel lines and carburetor 5 Turn fuel selector switch to OFF position Fully close the LPG cylinder knob if it is open and disconnect LPG cylinder from the generator 6 Allow the unit to cool entirely before cleaning and storage 7 Change oil with recommended grade oil 8 Remove spark plug and pour about one teaspoon of engine oil th...

Страница 34: ...arging circuit The battery will receive charging voltage when the engine is running The battery will maintain a proper charge if the unit is used on a regular basis about once every two weeks If it is used less frequently the battery should be connected to a trickle charger not included or battery maintainer not included to keep the battery properly charged If the battery is not able to start the ...

Страница 35: ...etor fill with fresh gasoline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility 12 Contact authorized service facility 13 Contact authorized service facility Engine lacks power 1 Load is too high 2 Dirty air filter 1 Don t Overload Generator 2 Replace air filter Eng...

Страница 36: ...Page 34 PARTS DIAGRAM AND PART LIST H07552 PARTS DIAGRAM English 145 146 ...

Страница 37: ...Page 35 439cc DUAL FUEL ENGINE PARTS DIAGRAM English ...

Страница 38: ...lange Bolt M5 16 Terminal Block Bolt M5 16 Ground Wire Generator End Cover Cap Flange Bolt M5 12 Flange Bolt M6 200 Lock Washer Ø6 Washer Ø6 Nut M5 Side Cover Bolt M5 229 Lock Washer Ø5 Flange Bolt M10 285 Lock Washer Ø10 Washer Ø10 Flange Bolt M8 20 Holder Muff Flange Bolt M6 12 Muffler Fixed Plate A Screw washer Assy M5 14 Holder Spark Arrester Arrester Spark Muffler Fixed Plate B Nut M8 Lock Wa...

Страница 39: ...drain Washer drain Bolt Oil Level Sensor Flg Bolt M6 15 Bearing Locating Pins Bearing Balance Shaft Camshaft Comp Crankshaft Gear Crank Shaft Gear Drive Gskt Crankcase Cover Oil Dipstick Assy Cover Crankcase Oil Seal Flange Bolt M8 40 Conn Rod Comp Piston Pin Retainer Ring Wrist Pin Piston Flange Bolt M6 12 Air Guide Lower Ring Oil Ring Second Piston Ring First Piston Gasket Valve Cover Valve Cove...

Страница 40: ... your name and address and a description of the defect 3 Ship to the address provided by ARC 4 Write the RMA number provided on the outside of the package What Your Warranty Does Not Cover Improper installation Failure of the product if it is abused misused or used for other than the intended purpose or used commercially Replacement of house fuses or resetting of circuit breakers Damage to the pro...

Страница 41: ...ngine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to the part as described in the engine manufacturers application for certification The warranty on emissions related parts is as foll...

Страница 42: ...fold Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps English Customer Service 1 844 FIRMAN1 Limitations This Emission Control Systems Warranty shall not...

Отзывы: