Installation, Use and Maintenance

This warranty will not apply to parts and/or labor 
if your product is deemed to have been misused, 
neglected, involved in an accident, abused, 
loaded beyond the generator's limits, modified, 
installed improperly or connected incorrectly to 
any electrical component. 
Normal maintenance is not covered by this 
warranty.

Other Exclusions

This warranty excludes:
– cosmetic defects such as paint, decals, etc.,
– wear items,
– accessory parts,
– failures to due acts of God and other force 
   majeure events beyond the manufacturer’s 
   control,
– problems caused by parts that are not original 

   

FIRMAN parts.

Limits of Implied Warranty and 
Consequential Damage

Contact Information

You may contact FIRMAN at:

Address

SUMEC North America
Attn: Customer Service
2090 Baker Road Suite 304 Box 105
Kennesaw Ga. 30144
www.firmangenerators.com 

Customer Service

Mon-Fri 8:30 AM- 5:30 PM (EST)
Toll Free:1-844-FIRMAN1(1-844-347-6261)

FIRMAN disclaims any obligation to cover any 
loss of time, use of this product, freight, or any 
incidental  or  consequential  claim  by  anyone 
from using this product. THIS WARRANTY IS IN 
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR 
I M P L I E D ,  I N C L U D I N G  W A R R A N T I E S   O F 
M E R C H A N T A B I L I T Y  O R  F I T N E S S  F O R  A 
PARTICULAR PURPOSE.

A unit provided as an exchange will be subject 
to the warranty of the original unit. The length 
of the warranty governing the exchanged unit 
will  remain  calculated  by  reference  to  the 
purchase date of the original unit.

T h i s  w a r r a n t y  g i v e s  y o u  c e r t a i n  l e g a l  r i g h t s 
w h i c h m a y c h a n g e f r o m s t a t e t o s t a t e . Y o u r 
s t a t e m a y a l s o h a v e o t h e r r i g h t s y o u m a y b e 
e n t i t l e d  t o  t h a t  a r e  n o t  l i s t e d  w i t h i n  t h i s 
w a r r a n t y .

Содержание P03602

Страница 1: ...performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number Purchase Date PORTABLE GENERATOR MODEL NUMBER P...

Страница 2: ...ounding 14 Operation 15 Generator Location 15 Surge Protection 15 Starting the Engine 16 Connecting Electrical Loads 17 Stopping the Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 MAINTENA...

Страница 3: ...ce Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the u...

Страница 4: ...o fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoning Avoid other generator hazards READ MANUAL BEFORE USE WARNING The engine exhaust from this product contains chemicals known to...

Страница 5: ...raction will pull hand and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly un...

Страница 6: ...or operation Turn electrical loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate...

Страница 7: ...f you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a med...

Страница 8: ...remove the attached engine support brackets red under the engine 1 Before filling the engine oil tip the generator back onto its recoil frame end as indicated in this picture Place the generator on th...

Страница 9: ...C F F The generator requires some assembly priorto usage If problem arise when assembling the generator call 1 844 347 6261 E G H K 1 Before adding wheels tip the generator on it s side 2 Slide the a...

Страница 10: ...erator 1 2 1 Fuel Gauge 2 5 0 Gallon Capacity Fuel Tank 3 Fuel Cap 4 Choke Lever 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 8 0 Flat Free Wheel 10 Oil Filler Cap 11 Outlet...

Страница 11: ...age to generator or equipment The circuit protector may be reset by pushing the button of the protector 4 5 7 Ground Terminal Consult an electrician for local grounding regulations 120V 30A Twist Lock...

Страница 12: ...uipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 104 F When your product is needed your product may be operated at temperatures ranging from 15 C 5 F t...

Страница 13: ...onally to allow stator windings to heat and cool Adjusting the load will also cause engine speed to vary and help seat piston rings CAUTION The unit is equipped with a low oil shutdown If the oil leve...

Страница 14: ...sary DO NOT light a cigarette or smoke when filling the fuel tank 1 Clean area around fuel fill cap remove cap 2 Slowly add unleaded fuel to fuel tank Be careful not to fill above the red fuel level i...

Страница 15: ...pment to prevent backfeed by isolating generator from electric utility workers When using generator for backup power notify utility company Use a ground fault circuit interrupter GFCI in any damp or h...

Страница 16: ...gine exhaust contains carbon monoxide a poisonous gas that could kill you in minutes You CANNOT smell it see it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon...

Страница 17: ...uring shipment 2 Check oil level and fuel 5 Move the choke lever to the START position 6 Flip the engine switch to the ON position 8 Do not over choke As soon as engine starts and warm up move the cho...

Страница 18: ...enerator with electrical devices plugged in or turned on This unit has been pretested and adjusted to handle its full capacity Before starting the generator disconnect all load Apply load only after g...

Страница 19: ...is below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Au...

Страница 20: ...commendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been s...

Страница 21: ...in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hour...

Страница 22: ...ner cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN 2 SCREEN 1 O ring CUP BODY b Remove spark plug using provided wrench c Inspect spark plug for damage a...

Страница 23: ...surface in a clean dry operating environment DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapours DO NOT use a garden hose to clean the generator Water can en...

Страница 24: ...ition LONG TERM STORAGE When the generator set is not being operated or is being stored more than one month follow these instructions 1 Replenish engine oil to upper level 2 Run the generator then clo...

Страница 25: ...ine has lost compression 1 Set engine switch to ON I position 2 Move fuel shutoff lever to ON I position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cle...

Страница 26: ...Page 25 PARTS DIAGRAM AND PART LIST PARTS DIAGRAM...

Страница 27: ...4 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 335713640 335713641 335713642 335713643 335713644 335713645 335713646 335713647...

Страница 28: ...nit to the Place of Purchase Contact the FIRMAN Service Center and FIRMAN will troubleshoot any issue via phone or e mail If the problem is not corrected by this method FIRMAN will at its option autho...

Страница 29: ...ress SUMEC North America Attn Customer Service 2090 Baker Road Suite 304 Box 105 Kennesaw Ga 30144 www firmangenerators com Customer Service Mon Fri 8 30 AM 5 30 PM EST Toll Free 1 844 FIRMAN1 1 844 3...

Страница 30: ...built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the failure of a warrant...

Страница 31: ...c b Diagnosis and inspection fees that do not result in eligible warranty service being performed 1 Ignition system including Spark plug Ignition coil 2 Fuel metering system Fuel tank Fuel cap Fuel li...

Страница 32: ...P N 336745450 Rev 00...

Отзывы: