Page 10
Control Panel
Engine Switch
– Flip the switch to the “On”
position and pull the recoil starter to start
the generator. Turn to the “Off” position to
turn off the generator.
1
2
Multi-moniter Meter
– Push the SELECT
button to show the Voltage, Hertz and running
hours. If the low oil indicator is light ,check
the oil level.
3
Circuit Breakers
– The receptacles are
protected by an AC circuit protector. If the
generator is overloaded or an external short
circuit occurs. the circuit protector will trip.
If this occurs, disconnect all electrical loads
and try to determine the cause of the
problem before attempting to use the
generator again. If overloading causes the
circuit protector to trip, reduce the load.
Note: Continuous tripping of the circuit
protector may cause damage to generator
or equipment.
The circuit protector may be
reset by pushing the button of the protector.
4
5
7
Ground Terminal
– Consult an electrician
for local grounding regulations.
120V, 30A Twist-Lock
(NEMA L5-30R)
120V, 20A Duplex
– (NEMA 5-20R) 20 amps
of current may be drown from the receptacle.
However, total power drawn must be kept
within name plate ratings.
1
2
3
4
5
6
7
6
120V, 30A RV
(NEMA TT-30R)
Total power drawn from all receptacles must not exceed the name plate rating.
NOTE:
Maximum full load current may be drawn
from this receptacle. Total current must be
limited to nameplate rating. If other
receptacles are used at the same time, total
power used must be kept within nameplate
ratings.
8
Outlet Cover -
Protect
the
receptacles from
dust and debris.
Maximum full load current may be drawn
from this receptacle. Total current must be
limited to nameplate rating. If other
receptacles are used at the same time, total
power used must be kept within nameplate
ratings.