English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

FIRMAN Three (3) Year Limited Warranty

Do Not Return the Unit to the Place of Purchase

Contact the FIRMAN Service Center and FIRMAN will troubleshoot any issue via phone or e-mail. 
If the problem is not corrected by this method, FIRMAN will, at its option, authorize evaluation, 
repair or replacement of the defective part or component at a FIRMAN Service Center. FIRMAN 
will provide you with a case number for warranty service. Please keep it for future reference. 
Repairs or replacements without prior authorization, or at an unauthorized repair facility, will 
not be covered by this warranty.

Normal Wear

Your product needs periodic parts and service to perform well. This warranty does not cover 
repair when normal use has exhausted the life of a part or the equipment as a whole.

FIRMAN warrants to the original purchaser that the mechanical and electrical components will be free of 
defects in material and workmanship for a period of one(1) year(parts and labor) and three(3) years (parts 
and technical support) from the original date of purchase 90 days [parts and labor] and 180 days [parts] 
for commercial & industrial use. Transportation charges on product submitted for repair or replacement 
under this warranty are the sole responsibility of the purchaser . This warranty only applies to the original 
purchaser and is not transferable.

Repair/Replacement Warranty

Warranty Exclusions

This warranty does not cover the following repairs and equipment.

Warranty Qualigications

FIRMAN GENERATOR will register the warranty upon receipt of your Warranty Registration Card 
and a copy of your sales receipt from one of FIRMAN’s retail locations as proof of purchase. Please 
submit your warranty registration and your proof of purchase within ten(10) days of the date of 
purchase.

40

SERVICE INFORMATION CONTACT FIRMAN PRODUCT SERVICE DEPARTMENT AT 1-844-347-6261
or at www.firmanpowerequipment.com to obtain warranty service information or to order
replacement parts or accessories.

HOW TO ORDER REPLACEMENT PARTS

Even quality-built equipment such as this electric generator may need occasional 
replacement parts to maintain it in good condition over the years. To order replacement parts, 
please give the following information:

Model No. Rev. Level and Serial No. found on the Data Decal.
Parts number or numbers as shown in the Parts List section.
A brief description of the trouble with the generator.

••

Service – Warranty

Содержание H07553

Страница 1: ...OPERATOR S MANUAL Record product information to reference when ordering parts or obtaining warranty coverage DUAL FUEL PORTABLE GENERATOR MODEL NUMBER H07553 Rev Level 01 P N 375745484 Rev 04...

Страница 2: ...o life safety support This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intende...

Страница 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 4: ...erator is designed to be used only with FIRMAN authorized parts FIRMAN The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacl...

Страница 5: ...D Extension cords running directly into the home increase your risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is used to power indoor items...

Страница 6: ...e on this page 05 FEATURES AND CONTROLS Generator 1 Fuel Gauge 2 8 0 Gallon Capacity Fuel Tank 3 Fuel Cap 4 Choke Lever behind air filter box 5 Air Filter 6 439cc FIRMAN OHV Engine 7 Recoil Starter 8...

Страница 7: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 06...

Страница 8: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 07...

Страница 9: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 08...

Страница 10: ...urrent may be drawn from this receptacle 8 120 240V 30A Twist Lock NEMA L14 30R Not GFCI protected 9 Ground Terminal Consult an electrician or authority having jurisdiction for local grounding require...

Страница 11: ...ments crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours...

Страница 12: ...rtable generator at least 5 ft 1 5m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator i...

Страница 13: ...chart to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of...

Страница 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Страница 15: ...contacting Customer Support Installation instructions are also available in the Technical Bulletin area of the FIRMAN website www firmanpowerequipment com NOTICE Operation using an alternative main j...

Страница 16: ...CSA B149 1 Natural Gas and Propane Installation Code as applicable If possible the fuel supply connection should be close to the outdoor operating location This will reduce the cost of the flexible fu...

Страница 17: ...generator is not started during this 4 minute period the portable generator will switch to Battery Power Saving Mode to conserve battery life NOTICE Your portable generator is equipped with an interna...

Страница 18: ...wly until resistance is felt and then pull rapidly to start engine 8 For electric start only Flip the engine switch to the START ll position for a few seconds and then release 3 sec OPERATION 5 Discon...

Страница 19: ...open the LPG cylinder knob 18 OPERATION 10 Allow portable generator to run at no load for a few minutes to stabilize before plugging in any electrical devices NOTICE If engine starts but fails to run...

Страница 20: ...PULL TO PRIME Pull the starter cord 1 2 times Pull slowly until resistance if felt and then pull rapidly 1 2 Times 19 OPERATION 9 For recoil start only Move the choke lever to the RUN position 10 For...

Страница 21: ...LPG cylinder and regulator is common during operation and normally is not an indication of a problem In unusual situations this frost may eventually restrict the flow of LPG gas to the generator resul...

Страница 22: ...r service If GFCI trips while in use reset and test the outlet Electric cords laying on the ground with worn insulation may trip the GFCI only use cords in good condition RESET TEST TEST MONTHLY FOLLO...

Страница 23: ...th the largest load first 5 Allow the engine to stabilize 6 Plug in and turn on the next item 7 Allow the engine to stabilize 8 Repeat steps 5 6 for each additional item Surge Protection There is a re...

Страница 24: ...oxide accumulated around generator Prior to restart move generator to an open outdoor area 20 ft 6 m from occupied spaces with exhaust pointed away Air out premises open windows and doors before reocc...

Страница 25: ...Turn the main fuel selector switch to OFF O position 3 Fully close the LPG cylinder knob 24 OPERATION GAS LPG If a cover is used do not install until unit has cooled NOTICE Disconnect the LPG cylinder...

Страница 26: ...lter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable experienced owner or by authorized...

Страница 27: ...re often CAUTION Avoid prolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap a...

Страница 28: ...aturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easier and run at pea...

Страница 29: ...t system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws reference Federal Regulation 36...

Страница 30: ...sition the spark arrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that...

Страница 31: ...control module This portable generator is equipped with an automatic battery charging circuit The battery will receive charging voltage only when the engine is running The battery will maintain a prop...

Страница 32: ...need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained turn main fuel sele...

Страница 33: ...nd carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility Engine lacks power 1 Load is too high 2 Dirty air filter 1 Don t Overload Generator...

Страница 34: ...asoline LPG 8 0 U S Gallons 30 3L 37 2 oz 1 1L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 9400 GASOLINE 8450 LPG FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section...

Страница 35: ...PARTS DIAGRAM AND PART LIST H07553 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 34 140 141...

Страница 36: ...439cc DUAL FUEL ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 35...

Страница 37: ...65 357713550 357713551 Engine Subassembly Rubber Cap B Rubber Cap A Flange Bolt M6 8 Generator Wind Shield Rotor And Stator Set Rotor Assy Stator Assy Stator Cover Generator End Cover Carbon Brush Ass...

Страница 38: ...718315 375718316 375718317 375718318 336713826 336713815 Rubber Pad Battery Bolt bend Hook Grommet Nut M5 Red Boot Battery Red Cable Boot starter Black Boot Flange Bolt M6 8 Air Filter Bracket Nut M6...

Страница 39: ...ip starter Handle Core Recoil Starter Knob Case Comp recoil Starter Spring starter Return Pulley recoil Starter Cord Spring patchet Patchet starter Clip Sprg pawl Guide Pawl Guide Screw pawl Guide Nut...

Страница 40: ...English Customer Service 1 844 FIRMAN1 39 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 41: ...arts for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to...

Страница 42: ...ct Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are h...

Страница 43: ...arranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on your small off r...

Страница 44: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 45: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W LUDLOW DR SUITE 6 WWW FIRMANPOWEREQUIPMENT COM PEORIA A...

Отзывы: