6. Disconnect all electrical loads from the generator. Never start or stop the generator with
electrical devices plugged in.
7. Move choke lever located on engine to “START” position.
(For electric start move to step (11))
8. For recoil start only - PULL-TO-PRIME Pull the starter cord 1-2 times. Pull slowly until resistance
if felt and then pull rapidly.
1-2 Times
19
OPERATION
9.For recoil start only - Move the choke lever to the “RUN” position.
10. For recoil start only - PULL-TO-RUN Pull the starter cord slowly until resistance if felt and pull
rapidly to run the portable generator.
If the engine fails to start in 1-2 pulls with choke in the RUN position, move choke lever to START
position and repeat the PULL-TO-PRIME step (8).