Firman H07553 Скачать руководство пользователя страница 37

H07553 Portable Generator

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

36

Parts Diagrams - Parts Lists - Wiring Diagram

NO. Part Number

Qty.

Description

NO. Part Number

Qty.

Description

1
2
3
4
5
6

6.1
6.2
6.3

7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46

46.1

46.2
46.3
46.4

47
48

48.1
48.2
48.3
48.4

49
50
51
52
53
54
55
56
57
58

58.1
58.2
58.3
58.4

59
60
61
62
63
64
65
66
67
68
69
70
71

71.1
71.2
71.3
71.4
71.5
71.6
71.7
71.8

72
73
74
75
76
77

375718300
357713501
357713524
336713528
357713573
380413510
380713544
380713545
380713557
357713506
357713507
336713525
357713563
380713504
336713519
336713523
336713520
336713522
336713519
357713509
336718309
380713506
336713577
380713507
380713508
336713514
336718301
336713516
336713517
357713523
357713515
336713531
336718302
357713516
336713538
357713517
336713536
357713518
336713534
336713509
336713533
357713520
380713538
357713535
357713592
357713536
357713514
336713559
357413506
336718313

357713538
336713557
336713561
336713558
357713579
336713806
357713711
336713542
336713543
336713549
357713578
336713546
336713547
393713018
317713577
336713807
357713548
357713580
380428300
336713637
380713003
336713636
336713639
336713638
393713016
380713533
330713509
357713546
336713540
380713532
357713531
357713584
336713509
375718301
336713691
375418300
357713532
357713533
336718318
357713585
375718320
336713558
357713554
357713527
357713598
375718302
392428300
336713565
357713550
357713551

Engine Subassembly
Rubber Cap B
Rubber Cap A
Flange Bolt M6×8
Generator Wind Shield
Rotor And Stator Set
Rotor Assy
Stator Assy
Stator Cover
Generator End Cover
Carbon Brush Assembly
Carbon Brush Holder
Bolt &washer Assemblies
AVR
Flange Bolt M5×16
Terminal Block
Bolt M5×16
Ground Wire
Flange Bolt M5×16
Generator End Cover Cap
Flange Bolt M5×12
Flange Bolt M6×200
Nut M5
Side Cover Bolt M5×229
Flange Bolt M10×285
Ground Wire
Flange Bolt M6×12
External Star Washer Ø6
Nut M6
Protector,muff.,back
Holder,muff
Flange Bolt M8×20
Flange Bolt M6×12
Protector,Muff.,side

Holder,Spark Arrester
Arrester,Spark
Protector,Muff.,Front
Nut M8
Lock Washer Ø8
Flat Washer Ø8
Gskt.,ext.
Muff.,assy.
Axle Comp
Wheel
Lock Pin
Washer Ø10
Flange. Bolt M8×16
Support Leg Assembly
Nut M6

Screw&washer Assy M5×14

Support Leg
Rubber, Support
Flange Bolt M6×25
Nut M8
Fuel Tank Assy.
Fuel Filter, Wire Mesh
Fuel Tank
Grommet, Fuel Tank
Washer Tank Buffer
Fuel Cap
Fuel Gauge Assy.
Screw M5×10
Fuel Gauge Display
Bolt M6×20
Clip
Tank Fitting With Filter
Clamp
Hose,fuel 1
Carbon Canister Assy
Carbon Canister
Flange Bolt M6×6
Carbon Canister Shield
Carbon Canister Bracket
Carbon Canister Holder
Flange. Bolt M8×16
Vapor Hose 2
Clip(

φ

8.7×8

Sleeve
Clamp Ø8×6
Vapor Hose 1
Nut M10
Flange Bolt M8×35
Lock Washer Ø8
Washer
Hose Holder
Frame
Isolator 2
Isolator 1
Nut M8
Motor Mount
Frame
Nut M8
Battery Holder
Flange. Bolt M8×50
Plug
Flange Bolt M8×12
CO Module
Screw  M5×14
Wing Nut M6
Battery Pressing Bracket

1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
1
1
2
4
2
2
1
1
1
1
4
1
1
4
7
1
2
1
1
1
2
2
2
1
1
2
2
2
2
2
1
2

1
2
2
2
1
1
1
4
4
1
1
2
1
4
1
1
3
1
1
1
2
1
1
1
2
1
1
1
2
1
2
2
2
2
1
1
1
1
4
2
1
2
1
2
2
2
1
5
2
1

Содержание H07553

Страница 1: ...OPERATOR S MANUAL Record product information to reference when ordering parts or obtaining warranty coverage DUAL FUEL PORTABLE GENERATOR MODEL NUMBER H07553 Rev Level 01 P N 375745484 Rev 04...

Страница 2: ...o life safety support This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intende...

Страница 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Страница 4: ...erator is designed to be used only with FIRMAN authorized parts FIRMAN The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacl...

Страница 5: ...D Extension cords running directly into the home increase your risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is used to power indoor items...

Страница 6: ...e on this page 05 FEATURES AND CONTROLS Generator 1 Fuel Gauge 2 8 0 Gallon Capacity Fuel Tank 3 Fuel Cap 4 Choke Lever behind air filter box 5 Air Filter 6 439cc FIRMAN OHV Engine 7 Recoil Starter 8...

Страница 7: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 06...

Страница 8: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 07...

Страница 9: ...FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1 08...

Страница 10: ...urrent may be drawn from this receptacle 8 120 240V 30A Twist Lock NEMA L14 30R Not GFCI protected 9 Ground Terminal Consult an electrician or authority having jurisdiction for local grounding require...

Страница 11: ...ments crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours...

Страница 12: ...rtable generator at least 5 ft 1 5m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator i...

Страница 13: ...chart to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of...

Страница 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Страница 15: ...contacting Customer Support Installation instructions are also available in the Technical Bulletin area of the FIRMAN website www firmanpowerequipment com NOTICE Operation using an alternative main j...

Страница 16: ...CSA B149 1 Natural Gas and Propane Installation Code as applicable If possible the fuel supply connection should be close to the outdoor operating location This will reduce the cost of the flexible fu...

Страница 17: ...generator is not started during this 4 minute period the portable generator will switch to Battery Power Saving Mode to conserve battery life NOTICE Your portable generator is equipped with an interna...

Страница 18: ...wly until resistance is felt and then pull rapidly to start engine 8 For electric start only Flip the engine switch to the START ll position for a few seconds and then release 3 sec OPERATION 5 Discon...

Страница 19: ...open the LPG cylinder knob 18 OPERATION 10 Allow portable generator to run at no load for a few minutes to stabilize before plugging in any electrical devices NOTICE If engine starts but fails to run...

Страница 20: ...PULL TO PRIME Pull the starter cord 1 2 times Pull slowly until resistance if felt and then pull rapidly 1 2 Times 19 OPERATION 9 For recoil start only Move the choke lever to the RUN position 10 For...

Страница 21: ...LPG cylinder and regulator is common during operation and normally is not an indication of a problem In unusual situations this frost may eventually restrict the flow of LPG gas to the generator resul...

Страница 22: ...r service If GFCI trips while in use reset and test the outlet Electric cords laying on the ground with worn insulation may trip the GFCI only use cords in good condition RESET TEST TEST MONTHLY FOLLO...

Страница 23: ...th the largest load first 5 Allow the engine to stabilize 6 Plug in and turn on the next item 7 Allow the engine to stabilize 8 Repeat steps 5 6 for each additional item Surge Protection There is a re...

Страница 24: ...oxide accumulated around generator Prior to restart move generator to an open outdoor area 20 ft 6 m from occupied spaces with exhaust pointed away Air out premises open windows and doors before reocc...

Страница 25: ...Turn the main fuel selector switch to OFF O position 3 Fully close the LPG cylinder knob 24 OPERATION GAS LPG If a cover is used do not install until unit has cooled NOTICE Disconnect the LPG cylinder...

Страница 26: ...lter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable experienced owner or by authorized...

Страница 27: ...re often CAUTION Avoid prolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap a...

Страница 28: ...aturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easier and run at pea...

Страница 29: ...t system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws reference Federal Regulation 36...

Страница 30: ...sition the spark arrester in the muffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that...

Страница 31: ...control module This portable generator is equipped with an automatic battery charging circuit The battery will receive charging voltage only when the engine is running The battery will maintain a prop...

Страница 32: ...need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained turn main fuel sele...

Страница 33: ...nd carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility Engine lacks power 1 Load is too high 2 Dirty air filter 1 Don t Overload Generator...

Страница 34: ...asoline LPG 8 0 U S Gallons 30 3L 37 2 oz 1 1L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 9400 GASOLINE 8450 LPG FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section...

Страница 35: ...PARTS DIAGRAM AND PART LIST H07553 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 34 140 141...

Страница 36: ...439cc DUAL FUEL ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 35...

Страница 37: ...65 357713550 357713551 Engine Subassembly Rubber Cap B Rubber Cap A Flange Bolt M6 8 Generator Wind Shield Rotor And Stator Set Rotor Assy Stator Assy Stator Cover Generator End Cover Carbon Brush Ass...

Страница 38: ...718315 375718316 375718317 375718318 336713826 336713815 Rubber Pad Battery Bolt bend Hook Grommet Nut M5 Red Boot Battery Red Cable Boot starter Black Boot Flange Bolt M6 8 Air Filter Bracket Nut M6...

Страница 39: ...ip starter Handle Core Recoil Starter Knob Case Comp recoil Starter Spring starter Return Pulley recoil Starter Cord Spring patchet Patchet starter Clip Sprg pawl Guide Pawl Guide Screw pawl Guide Nut...

Страница 40: ...English Customer Service 1 844 FIRMAN1 39 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Страница 41: ...arts for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to...

Страница 42: ...ct Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are h...

Страница 43: ...arranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on your small off r...

Страница 44: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Страница 45: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W LUDLOW DR SUITE 6 WWW FIRMANPOWEREQUIPMENT COM PEORIA A...

Отзывы: