AerPOS Series AP-3435
14
Cash Drawer Installation
Before connecting the cash drawer to the AP-3435, please make sure the drive voltage and cable
pin assignment of the cash drawer matches the definition of the cash drawer port of AP-3435.
Please refer to the jumper setting and pin definition for FH-5251 MB Manual.
Note: If the cash drawer cannot be detected by the system, please refer to trouble shooting.
Up to two cash drawers may be driven from this port. Driving voltage of the solenoid is
DC+12V. I/O port 284 is used for drawer operation. A test program is supplied, for Linux and
Windows, sample code of which is available on request by software developers.
Value
Description
0x284
Output address.
0x284 read 8bit
Bit 2 => 0: low 1: high
0x200
Sleep 200ms
0x01
Open cashdrawer1 value.
0x02
Open cashdrawer2 value.
0x04
Close cash-drawer value.
0x04
Cash-drawer status mask.
COM 1
DC IN
DC OUT
COM 4
USB
COM 2
VGA
LAN
USB
LPT
PS2 Cash Drawer
Line Out
COM 5
COM 3