background image

®

 

11

 

 

 

 

 
 

13.  ORDERING INFORMATION 

Before ordering, please provide the data as in Appendix 3

The Table 1 below shows examples of the Part Numbers 

of length “L” 

every 0.5 metre, the fuel options of Natural 

Gas or Propane Gas/LPG in typical capacity ranges as in Appendix 1.

 

Pilots can be ordered in size increments of 0.1 metre lengths, from 0.5 to 3.0 metres.

 

Part Number coding samples:

 

SP-48-NG-FD-1.5  or  SP-48-PG-FD-1.5  

 

Which means:   SureFire  II™  Pilot

  - 

48

  mm  OD  -  Natural  Gas  (

NG

)  or  Propane  Gas/LPG  (

PG

)  -  Forced 

Draught (

FD

) - 

1.5

 metre insertion length 

 

Table 1:  SureFire  II

™  Forced  Draught  Pilot  selection  Table,  showing  only  the  0.5  metre  intervals,  0.1  metre 

intervals may be ordered (See Price List).  

REMARKS:   
1.   Select required kind of fuel 

– choose NG for Natural Gas or PG for Propane Gas or LPG.  

2.  Select Electric Igniter rod and power pack separately 

 

Part No

 

Description

 

SP-48-NG/PG-FD-0.5 
 

SureFire II

™ Pilot, 48 mm OD, Nat. Gas or Propane Gas, Forced Draught, 0.5 m ins. length 

 

SP-48-NG/PG-FD-1.0

 

SureFire II

™ Pilot, 48 mm OD, Nat. Gas or Propane Gas, Forced Draught, 1.0 m ins. length

 

SP-48-NG/PG-FD-1.5

 

SureFire II

™ Pilot, 48 mm OD, Nat. Gas or Propane Gas, Forced Draught, 1.5 m ins. length

 

SP-48-NG/PG-FD-2.0

 

SureFire II

™ Pilot, 48 mm OD, Nat. Gas or Propane Gas, Forced Draught, 2.0 m ins. length

 

SP-48-NG/PG-FD-2.5

 

SureFire II

™ Pilot, 48 mm OD, Nat. Gas or Propane Gas, Forced Draught, 2.5 m ins. length

 

SP-48-NG/PG-FD-3.0

 

SureFire II

™ Pilot, 48 mm OD, Nat. Gas or Propane Gas, Forced Draught, 3.0 m ins. length

 

 

The Table 2 below shows Part Numbers of gas igniter mounting tubes and spare parts. 

Table 2:  SureFire II

™ Pilot Mounting Tubes & Spare Parts  

 

Part No

 

Description

 

SP-48-MTF 

Mounting Tube Flanged, flange OD 80, length 120mm 

SP-48-MTW-150 

Mounting Tube for Welding,  length 150 mm 

SP-48-MTW-600 

Mounting Tube for Welding,  length 600 mm 

SP-32/48-LS-SET 

Loose Spare Part set for SP32 and SP-48 pilots * 

SP-48-FD-STOR 

Stabilizer assy: swirler-stabilizer, divider, main & bleed orifice for SP-48-FD  

SP-48-END 

Air tube end with inlets, 200 mm long, SS310, for SP-48-ND and SP-48-FD 

*   Loose Spare Part set includes items as on Fig. 5 

 

Special Pilots:  

Not all applications can be easily coded to cover every requirement. In order to provide for these, there is a 
supplementary Part Numbering system. It is used in case of applications that require: 

-  other Natural gas or Propane gas capacity ranges than standard needed,  
-  other Fuel gas than specified above 

– see Remarks in Appendix 3

,  

-  other pilot construction needed. 

In such case please provide the data as in Table in Appendix 3, especially the gas composition. It is required 
for the proper selection of materials used for pilot construction and feasibility of operation checking. 

Part Number in such case is SP-48-ZYY-F-xxx where:  

Z

”   is capacity range e.g. 

S

-small, 

M

-medium, 

L

-large or possibly others, 

YY

”  is the specific 

Project Number 

given by Fireye after analyzing the Proposal Data Sheet,

 

F

”   is 

Forced draught

,

  

xxx

”  is the length 

L

REMARKS:  Fireye will provide a special price for the pilot after Proposal Data Sheet analysis.  

Fireye may refuse to execute of an order if considered as impossible to complete.

 

 

Содержание SureFire II SP-48-NG-FD

Страница 1: ...d each unit is checked and tested before dispatch Acquaintance with the following instructions and strict attention to the indications reduce the possibility of equipment failure to a minimum and ensu...

Страница 2: ...xits the main nozzle at the outlet of the air tube The main flame then stabilizes in the primary combustion zone at the outlet of the air tube The swirler stabilizer plate and holes in air tube provid...

Страница 3: ...he Fireye High Tension Igniter the end of the rod tip should be placed at a distance of 10 mm back from the swirler stabilizer see Fig 1 In case of the High Energy Spark Igniter the rod tip should be...

Страница 4: ...ling the pilot burner please follow the rules below 6 1 Use pilot only for its intended purpose 6 2 At the time of installation operation and maintenance follow the procedures described in the instruc...

Страница 5: ...he burner plate with a diameter slightly larger than the diameter of the mounting tube b The mounting tube for welding slide the mounting tube in the hole and set it in the correct position insertion...

Страница 6: ...tors may be used c To ensure a long and trouble free operation of the pilot it should be kept clean Check the condition of the gas pipe and if the orifices are not blocked Remove all buildups Hoses sh...

Страница 7: ...flame stabilizes at the end of the air tube and reaches a blue yellow color If the airflow is too low the end of the air tube may start to glow it starts to glow at 400 500 C as the main flame burns i...

Страница 8: ...the flame after trial for ignition the valves are closed and electrical igniter is switched off i Eventual repeating of trial for ignition sequence depends on the application Details of sequence timin...

Страница 9: ...does not operate correctly check the following a All manual gas valves on gas supply line were open and there is gas available b All valves in the supply line are functioning properly c The preset gas...

Страница 10: ...intenance of igniter contrary to the instructions in the user manual unauthorized igniter modifications or repairs made by unauthorized personnel use of components or spare parts other than original 1...

Страница 11: ...ght 3 0 m ins length The Table 2 below shows Part Numbers of gas igniter mounting tubes and spare parts Table 2 SureFire II Pilot Mounting Tubes Spare Parts Part No Description SP 48 MTF Mounting Tube...

Страница 12: ...12 APPENDIX No 1 The Pilot capacity vs gas pressure graphs standard version Remark The real measured capacity may differ by 5 depending on a particular pilot and measurement conditions...

Страница 13: ...us pilot on a sample main burner with gas spuds and central oil or gas gun vertical mounting The pilot air tube tip can be mounted in the throat or in the swirler Pilot tip cannot extend beyond the he...

Страница 14: ...nd especially refinery gas Refinery Off Gas needs additional engineering and testing because their gas compositions and calorific values are different than these of NG PG and LPG taken for gas pilot d...

Страница 15: ...5 cubic foot ft3 Air flow rate 1 cubic metre hour m3 h x 0 589 standard cubic foot min SCFM Weight 1 kilogram kg x 2 2046 pound lb Pressure 1 kilopascal kPa x 6 895 pound square inch gauge psig x 4 01...

Страница 16: ...is found defective in material or workmanship or which otherwise fails to conform to the description of the product on the face of its sales order THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES AND...

Отзывы: