background image

5

How to Install Your CO Alarm cont.

11. Firmly 

PRESS AND RELEASE THE

TEST/RESET button. 

See Figure 7. The

alarm should sound a short tone. The amber
service light will turn on, and the CO alarm
will go through its test cycle. The red LED
will flash, and the alarm will beep four times
followed by 5 seconds of silence and then
repeat the cycle. After the test cycle, amber
service light will turn off, and the green
power light will remain lighted which means
that the CO alarm is operating properly.

12. If the alarm is interconnected to other CO alarms, press and hold the RESET/TEST

button until the red light turns on. Other interconnected alarms will also beep four
times followed by 5 seconds of silence. The red alarm light on other alarms will not
light during this test.

13. Two self-adhesive labels have been provided with instructions indicating what to do

if the alarm sounds. Add the phone numbers of your emergency services provider
and a qualified technician to each label. Place one of the labels in a visible area next
to the alarm, and place the other label near a source of fresh air which will be used
as a gathering place if the alarm sounds.

How to Operate Your CO Alarm

This carbon monoxide alarm has been evaluated by UL and meets the applicable
UL standards and requirements. 

This CO alarm has a three light and sound alarm 
system:

On

Green indicator constantly on indicates unit is receiving AC power.

Service

Amber indicator flashing and alarm horn beeping every thirty sec-
onds indicates unit fault. Press and release the TEST/RESET button.
If the alarm returns to displaying the fault signal, the CO alarm is not
operating properly. REPLACE THE CO ALARM IMMEDIATELY. SEE
THE WARRANTY INFORMATION AT THE END OF THIS MANUAL.

Alarm

Red indicator flashes and alarm horn sounds four fast beeps and then
is quiet for 5 seconds.

Low Battery

The unit will emit a chirp once every 30 seconds when the battery is
low and needs to be replaced.

When the CO concentration builds to a level that is equal to 70 ppm or greater for
the duration identified within the standard, the following will occur:
• The alarm light and sound signals will activate. See the “What To Do If Your Alarm

Sounds” section of this manual for important action steps to be taken.

• If you wish to press the TEST/RESET button during this time, the alarm will

become quiet for approximately four minutes. The alarm signals will be reener-
gized within 4 minutes from the time the reset button is pressed if the concentra-
tion of carbon monoxide surrounding the alarm remains at 70 ppm or greater.

• The alarm will remain silent if the CO concentration has decreased below the

alarm level of the standard. See “What To Do If Your Alarm Sounds” section of
this manual for important action steps to be taken.

• The alarm will continue for as long as the condition exists.

The alarm will not permanently end its alarm mode until the concentration of CO
has been reduced to a safe level.

(Power on/ operating)

(Problem with Alarm)

(Dangerous CO levels)

FIGURE 7

PRESS
IN, HOLD,
AND
RELEASE
TO
RESET
AND/OR
TEST.

ON

SERVICE

ALARM

:

M

OVE

T

O

F

RESH

A

IR

CARBON MONOXIDE ALARM

(For COQ6 only)

Содержание COQ3

Страница 1: ...mind for you and your family The Maple Chase Company 2 The Dangers of Carbon Monoxide CO 2 CO Alarm Features 3 Where to Install Your CO Alarm 4 How to Install Your CO Alarm 5 How to Operate Your CO A...

Страница 2: ...t safety tips to safeguard your family from deadly CO poisoning The following symbols identify the most important safety messages in this manual When you see this symbol be aware that if the message i...

Страница 3: ...el of the home where household members frequently spend time as well as in the basement See Figures 1 2 and 3 for typical CO alarm locations within the home This alarm will only indicate the presence...

Страница 4: ...the CO alarm to white household wire 07 Connect black wire from the CO alarm to the black household wire 08 For interconnecting CO alarms only Use 18 AWG minimum solid or stranded wire When interconn...

Страница 5: ...beeping every thirty sec onds indicates unit fault Press and release the TEST RESET button If the alarm returns to displaying the fault signal the CO alarm is not operating properly REPLACE THE CO AL...

Страница 6: ...s and inspect for proper operation of this equipment If problems are identified during this inspection have the equipment serviced immediately Note any combustion equipment not inspected by the techni...

Страница 7: ...iented they are unable to save them selves by either exiting the building or calling for assistance Also young children the elderly and household pets may be the first affected by CO poisoning The imp...

Страница 8: ...ect CO poisoning seek medical assistance immediately WHERE TO SEND YOUR CARBON MONOXIDE ALARM FOR SERVICE To return carbon monoxide alarms under warranty send the CO alarm plus postage prepaid a note...

Страница 9: ...tecteur Vous et votre famille serez ainsi plus en s curit The Maple Chase Company 10 Les dangers du monoxyde de carbone 10 Caract ristiques du d tecteur de CO 11 O installer votre d tecteur de CO 12 C...

Страница 10: ...e famille des risques d empoisonnement mortel au CO Dans le pr sent guide les consignes de s curit les plus importantes sont identifi es par les symboles suivants DANGER Si vous ne tenez pas compte de...

Страница 11: ...trouverez des exemples d installations types aux Figures 1 2 et 3 ci dessous ATTENTION Le d tecteur d c le seulement la pr sence de monoxyde de carbone au niveau du capteur Du CO pourrait s tre accumu...

Страница 12: ...blanc du bo tier de jonction 07 Reliez le fil noir du d tecteur au fil noir du bo tier de jonction 08 Si vous installez plusieurs d tecteurs en s rie Employez du fil plein ou toronn de calibre 18 AWG...

Страница 13: ...lum et l avertisseur retentit aux trente d faillance secondes Cela indique une d faillance du d tecteur Appuyez sur le bouton TEST RESET Si le voyant jaune s allume encore le d tecteur ne fonctionne p...

Страница 14: ...et en v rifie le fonctionnement Si le technicien d c le une anomalie dans un appareil faites le r parer sans d lai Prenez note de tout appareil combustion qui n a pas t inspect par le technicien et c...

Страница 15: ...carbone il semble que bien qu elles soient conscientes de leur malaise les victimes deviennent d sorient es au point d tre incapables de sortir de la maison ou d appeler du sec ours Les jeunes enfant...

Страница 16: ...semblables ceux de la grippe ou vous pensez tre victime d une intoxication au CO Dans ce cas appelez imm diatement les services d assistance m dicale GARANTIE GARANTIE LIMIT E 5 ANS Maple Chase Compan...

Отзывы: