www.desatech.com
114745-01D
17
WARNING: Burners will
come on automatically within
one minute when the switch
is in the ON position after the
pilot is lit.
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information, starting in column 1 of
this page. If you don’t smell gas, go to the
next step.
6. Press in and turn control knob counter-
clockwise
to the PILOT position.
Press in control knob for five (5) seconds
(see Figure 17).
Note:
You may be running this heater for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note:
If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure
, page 18.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualified service person
or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 4
through 8, page 16.
OPERATING HEATER
Continued
Figure 17 - Control Knob and Ignitor
Button Location, Manual Controlled
Piezo
Ignitor
Switch in
OFF Position
Control Knob
Flame Adjustment Knob
9. Slightly push in and turn control knob coun-
terclockwise
to the ON position.
10. Wait one minute and switch selector switch
to the ON position to light burners.
Note:
AUTO is only functional when using
GWMT1 or GWMS2 optional accessories.
11. Set flame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise
to the
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away
from home for long periods of
time. Heater will come on auto-
matically with selector switch in
the ON position.
Figure 18 - Pilot
Ignitor
Electrode
Pilot
Burner
Natural
Ignitor
Electrode
Pilot
Burner
Propane/LP
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to the
OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote:
Set selector switch in the OFF position to
prevent draining battery.
3. Close equipment shutoff valve (see Figure
14, page 15).