20
AP User Guide
February 2009
Model 4100 Indoor Unit Specifications
Enclosure
Plastic enclosure.
Two RP-SMA antenna connectors, with 1 pair of 5 dBi 2.4 GHz omnidirectional antennas.
One DC power connector.
One RJ-45 Ethernet connector, CSMA/CD 10/100 autosense.
System indicator LEDs: power, status.
Weight: 10 oz. (270 g).
Dimensions: 6” x 4.75” x 1” (150 x 120 x 25 mm).
Power
DC Input: 11-16 VDC, 0.7 A at 12 VDC.
AC power adapter: 100-240 VAC, 50/60 Hz input; 12 VDC, 1.5A rated output.
Environmental Specifications
Operating temperature: 0º C to +60ºC.
Storage temperature: -40º C to +70º C.
Humidity (non-condensing): 10% to 90%.
Storage humidity (non-condensing): 5% to 95%.
Maximum altitude 15,000 feet (4600 meters).
Model 4500 Indoor Unit Specifications
Enclosure
Plenum rated per UL2043.
System indicator LEDs (power, uplink, access, status).
Two antenna connectors: SMA, reverse polarity.
Power connector.
One RJ-45 Ethernet connector, CSMA/CD 10/100 autosense.
Reset button (recessed).
Security slot for physical locking device.
Weight: 2.1 lbs (.95 Kg) without external transformer.
Dimensions: 9.00 in x 5.84 in x 1.07 in (22.85 cm x 14.83 cm x 2.71 cm).
Power
DC Input: 5 VDC, 2.0 A.
AC power adapter: 100-240 VAC, 50/60 Hz input.
Environmental Specifications
Operating temperature: -20º C to +60ºC.
Storage temperature: -20º C to +70º C.
Humidity (non-condensing): 10% to 90%.
Storage humidity (non-condensing): 10% to 90%.
Maximum altitude 15,000 feet (4600 meters).