FireSales Neptune
Problem
Possible cause
Solution
Practice extinguisher doesn’t
build up pressure/gauge 1
remains on 0.
The air supply is not connected
correctly.
The compressor is switched off.
The compressor is defective.
Check the connection and
whether gauge 2 is pressurised.
Switch the compressor on.
Please contact
FireWare
.
Practice extinguisher doesn’t
fill up/gauge 2 remains on
0.
The water supply is not
connected properly.
The water supply tap is closed.
Check the water supply
connection.
Open the water supply tap.
The filling station doesn’t
add foam.
The liquid tank is empty.
The yellow dosing lever is set
on 0%.
The foam supply is blocked or
defective.
Fill the tank with
FireSales Prac-
tice Foam
or connect a new one.
Increase the foam percentage
with the yellow dosing lever.
Please contact
FireWare
.
The extinguisher is empty
fast.
The compressor does not have
enough capacity.
Choose for a 15 bar compressor.
Other
Please contact
FireWare
.
To maintain the optimal performance of the
FireSales Neptune
, it should be properly maintained.
•
Make sure the fluid tank is clean at all times.
•
Clean the machine on a regular basis. You can clean the outside with a moist cloth and mild
detergent.
•
If you intend storing the
FireSales Neptune
for a longer time or at temperatures around
freezing (below 2˚C), you must drain all water from the device according to the following
procedure.
Draining the water:
1.
Connect an empty fire extinguisher (7).
2.
Connect the waterless hose to the water connection (5) and the other end to the air
connection (4).
3.
Switch the red handle water/air/off (9) to water.
4.
The rest of the water now drains into the fire extinguisher and the filling station can be
stored safely.
5.
Finally, empty the fire extinguisher completely, so no pressure remains. The fire extinguisher
can then be filled with the normal procedure with the next use.