FireplaceXtrordinair Ember-Glo 864 GSR2 Скачать руководство пользователя страница 4

Safety Precautions 

© Travis Industries 

3/30/2021 - 1485 

864 GSR2 40k Owners 

 

  IF YOU SMELL GAS: 

* Do not light any appliance 
* Extinguish any open flame 
* Do not touch any electrical switch or plug or unplug anything 
* Open windows and vacate building 
* Call gas supplier from neighbor's house, if not reached, call fire department 

   

 

 

This unit must be installed by a qualified installer to prevent the possibility of an explosion.  
Your dealer will know the requirements in your area and can inform you of those people 
considered qualified.  The room heater should be inspected and cleaned before use and at 
least annually by a qualified service person.  More frequent cleaning may be required due 
to excessive lint from carpeting, bedding material, etc.   

 

The instructions in this manual must be strictly adhered to.  Do not use makeshift methods 
or compromise in the installation.  Improper installation will void the warranty and safety 
listing. 

   

 

 

 

This heater is either approved for natural gas (NG) or for propane (LP).  Burning 

the incorrect fuel will void the warranty and safety listing and may cause an 
extreme safety hazard.  Direct questions about the type of fuel used to your dealer.  
Check for a label on the flame adjust knob on the gas control valve (this is the best 
place to check).  You may also check for a label on the gas control valve body. 

   

 

 

Contact your local building 
officials to obtain a permit and 
information on any installation 
restrictions or inspection 
requirements in your area.  
Notify your insurance company 
of this heater as well. 

 

  If the flame becomes sooty, dark 

orange in color, or extremely tall, 
do not operate the heater.  Call 
your dealer and arrange for 
proper servicing. 

 

 

It is imperative that control 
compartments, screens, or 
circulating air passageways of 
the heater be kept clean and 
free of obstructions.  These 
areas provide the air necessary 
for safe operation. 

 

  Do not operate the heater if it is 

not operating properly in any 
fashion or if you are uncertain.  
Call your dealer for a full 
explanation of your heater and 
what to expect. 

 

 

Do not store or use gasoline or 
other flammable liquids in the 
vicinity of this heater. 
 

 

  Do not operate if any portion of 

the heater was submerged in 
water or if any corrosion occurs.  
Immediately call  a qualified 
service technician to inspect the 
appliance and to replace any part 
of the control system and any 
gas control that has been under 
water. 

Содержание Ember-Glo 864 GSR2

Страница 1: ...ED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children a...

Страница 2: ...formation occur Installation Warnings Installation requirements are printed in the 864 GSR2 Installation Manual All requirements in the installation manual must be met Failure to follow all of the req...

Страница 3: ...Transmitter Battery Installation 15 Power Outages 15 Child Proof Feature 16 Normal Operating Sounds 16 Normal Operating Odors 16 Maintaining Your Fireplace s Appearance 17 Yearly Service Procedure 17...

Страница 4: ...ty hazard Direct questions about the type of fuel used to your dealer Check for a label on the flame adjust knob on the gas control valve this is the best place to check You may also check for a label...

Страница 5: ...instructions included in this manual If the main burners do not start correctly turn the gas off at the gas control valve and call your dealer for service Instruct everyone in the house how to shut g...

Страница 6: ...THE REMOTE The SIT GSR2 remote may be programmed to disable the thermostat or any of the modes flame height blower light comfort control Standing Pilot or auxiliary power input This allows you to tai...

Страница 7: ...he battery box IFC will beep 3 times 2 Press the ON button on the transmitter IFC will beep 3 times Figure 2 NOTE If power is cut off to the IFC for an extended period of time you may need to re synch...

Страница 8: ...of transmitter settings REMOTE Burner is controlled by the transmitter NOTE When the battery holder switch is turned to ON or OFF the mode settings Flame Height Comfort Control will remain in the sam...

Страница 9: ...continuous pilot are Very Cold Conditions in very cold conditions you may notice that the burner does not light quickly and the flames lift off the burner If this is situation we recommend you switch...

Страница 10: ...he need to reset the pilot mode during the heating season we have listed a few strategies below Option 1 Remember to periodically turn on the heater during the heating season If you use your heater fo...

Страница 11: ...d easily Display Overview The transmitter display has four main sections see Figure 4 Figure 4 Listen for the Beep Each time you press a button on the transmitter that controls the fireplace a beep wi...

Страница 12: ...the target temperature see Figure 7 below Flame height will be adjusted up or down to allow operation without turning the burner on and off also called smart modulation To adjust the target temperatur...

Страница 13: ...will display the 7 settings from OFF to HI for full on NOTE Flame height may not be adjusted if operating in Smart Thermostat setting Figure 10 Blower Speed The blower may be controlled using the up a...

Страница 14: ...e Flame Height to OFF see above Comfort Control rear burner The comfort control rear burner may be turned on and off using the up and down buttons when in Comfort Control Mode see illustration below T...

Страница 15: ...ries into the battery box when this occurs see Battery Installation on page 15 In applications where the appliance is required to provide heat we recommend replacing the batteries before each heating...

Страница 16: ...o turn this feature on and off see Figure 14 below HINT This feature is especially useful while using the thermostat setting Figure 14 Normal Operating Sounds Normal Operating Odors This appliance has...

Страница 17: ...rea around the pilot to make sure there is no damage Inspect primary air openings for blockage If any problem is found discontinue use and contact your dealer for service Inspect the area behind the a...

Страница 18: ...stries 3 30 2021 1485 864 GSR2 40k Owners Grill Installation and Removal Some fireplaces may use grills above and below the glass See the instructions below to remove Note Install the barrier screen b...

Страница 19: ...nance 19 Travis Industries 3 30 2021 1485 864 GSR2 40k Owners Face Installation and Removal Some fireplaces have a face that fits over the glass frame The face can be removed following the directions...

Страница 20: ...designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals If the barrier beco...

Страница 21: ...ners Glass Frame Removal and Installation Warning The appliance must be completely cool before removing the glass Warning Do not strike or slam the glass Note Remove the barrier before removing the gl...

Страница 22: ...30 2021 1485 864 GSR2 40k Owners Glass Frame Removal and Installation continued The latch can come loose from the latch assembly This occurs only when it is rotated Follow the directions below to re i...

Страница 23: ...uring the Light Housing to the ceiling of the firebox set aside for reinstallation NOTE Take care not to damage the gasket that seals the Light Housing to the top of the fireplace If the gasket appear...

Страница 24: ...ctions below Shut off gas to the fireplace and let it cool for 15 minutes Remove the barrier screen and glass assembly see page 20 Remove the media tray skirt Locate the burned out bulb and remove it...

Страница 25: ...details Classic Log Set Overview When installed the ten 10 logs should appear as shown below The directions on the following pages detail installation of this log set Right Log 250 01490 Front Ember C...

Страница 26: ...ockets that insert over two tabs on the back burner see photos below Place the log in place and push it back The log straddles the burner and does not cover any burner holes Right Log The right log ha...

Страница 27: ...left log has a channel that fits over the grate When in place the knob on the front of the log fits over the grate as well Left Log The left log has a channel on the bottom Place this channel over th...

Страница 28: ...s shown below It has a pin on the bottom side When in place the fork on the front straddles the grate and the pin rests on the rear burner make sure it is not over any burner holes Front Ember Chunk T...

Страница 29: ...ow The front left log has a groove that will point the twig upwards and to the right Center Left Twig The left center twig is flat on the bottom and has a fork at one end Place the twig as shown below...

Страница 30: ...k and a fork on the front Position the log so this fits over the pin on the back log Make sure the fork on the front of the log fits over the grate as shown below Right Twig The right twig has a hole...

Страница 31: ...The included rock wool is placed on top of the burner to enhance the glow from the burner The rock wool works best when it is applied in a very thin porous layer The best method for applying the rock...

Страница 32: ...witch to ON Check thermostat Blower Does Not Work The fireplace is not getting electricity The fireplace has not been on long enough The blower fuse may be blown Check the breaker switch Let the firep...

Страница 33: ...by a licensed or qualified service person Contact your local Travis Industries Dealer for a Replacement Parts List 3 15A FUSE Orange Yellow System Jumper Purple Grey Pilot Sensor Spark Rod Comfort Co...

Страница 34: ...34 Maintenance Travis Industries 3 30 2021 1485 864 GSR2 40k Owners Safety Label...

Страница 35: ...nce is in transit alteration or act of God 8 This 7 Year warranty excludes damage caused by normal wear and tear such as paint discoloration or chipping worn or torn gasketing corroded or cracked logs...

Страница 36: ...ngs 2 Intermittent Continuous Pilot 9 Location of Controls 8 Log Installation 25 Low Battery Indicator 15 Normal Operating Odors 16 Normal Operating Sounds 16 Pilot Fuel Conservation Timer 10 Power Ou...