22
Finalizing the Installation
(for qualified installers only)
© Travis Industries
4/23/2021 - 1552
564 GSR2 35K CF
Approved Vent
Horizontal Terminations
: use 8" (203mm) diameter Dura-Vent Model Direct-Vent Pro*.
Vertical Terminations
: Use 6-5/8" (168mm) diameter Dura-Vent Direct-Vent Pro*. Attach the 8"
(203mm) to 6-5/8" (168mm) reducer (Travis part # 98900165) to the fireplace.
* Other vent may be approved with this fireplace. Check with the vent manufacturer for details.
Termination
Always use the high-wind cap (part # 58DVA-HC, 58DVA-VCH, 46DVA-VCH).
Vent Installation
Installation instructions for Dura-Vent may be found at www.duravent.com
Slide the vent sections together and turn 1/4 turn until the sections lock in
place.
Screws are not required to secure the vent. However, three screws may be
used to secure vent sections together if desired.
High-temperature sealant is recommended at the appliance starter section
connection (use high-temperature silicone or Mill-Pac®).
If disassembly is required, at the time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high-temperature sealant to the joints
of the affected sections.
Horizontal sections require a 1/4" (6mm) rise every 12" (305mm) of travel
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)
6-5/8" (168mm) Diameter Vent
Reducer - # 98900165