![FireplaceXtrordinair 44-Elite Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/fireplacextrordinair/44-elite/44-elite_installation-manual_2291994025.webp)
Installation
(for qualified installers only)
25
© Travis Industries
4050714
93508093
Hearth Requirements
•
Local building codes may require a minimum hearth requirement different of what this manual
states
•
Hearth must extend 20" in front of the faceplate when it is not elevated (see local building
codes). Hearths raised 6-1/2" must extend a minimum 18".
•
Hearth must extend a minimum 8" to both sides of the faceplate (
60
" wide)
•
Hearth must be a minimum 1" thick of cement board (or equivalent)
•
Hearth must not rise more than 6-1/2" above the base of the fireplace
AAAAAA
AAAAAA
AAAAAAAAA
AAAAAAAAA
Combustible
Floor
No hearth material can
go above this point
Fireplace
Faceplate
Ember
Strip
6 1/2"
Max.
18" Min.
(Check Local Building Codes)
AA
AA
AA
AAAAAAAAA
AAAAAAAAA
A
A
A
A
AAAAAAAAA
AAAAAAAAA
AA
AA
AA
Minimum 1" cement board
Fireplace
Ember
Strip
2 x 4 Framing
No combustible material
permitted above this point
15"
Raised
hearth
3/4"
Plywood
AAAAAAAAA
AAAAAAAAA
A
A
A
Fireplace
2 x 8 Framing
Faceplate
Ember
Strip
15"
Raised
hearth
Elevated hearths must be
constructed of non-combustible
materials such as cement blocks
(6-1/2” Max.).
20" Min.
(Check Local Building Codes)
Tile or
marble
Fireplace
A
A
A
A
Faceplate
Combustible Floor
Ember
Strip
Header height needs to be
increased this dimension.
Header height will
need to be increased
this dimension.
Min. 1" cement board
(or equivalent)
Tile or
marble
3/4"
Plywood
Tile or
marble
Figure 30