Installation

  

(for qualified installers only)

11

© Travis Industries

4050714

93508093

Fireplace Placement

 

The  fireplace  must  be  secured  to  the  floor  (use  the  lifting  handle  brackets  -  see  Figure  10).

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AA

AA

AA

AA

AA

AA

Travis Industries 
recommends the chase 
around the fireplace be 
insulated.  This insulation 
should only be placed 
between the framing 
members and secured so 
it does not fill the space 
between the fireplace and
standoffs.

Bend this bracket down 
on each side and nail it 
to the floor, securing the 
fireplace in position.

Lifting handles are available 
separately (98500711).  They 
attach to the nail down brackets.

Standoffs (also 
located on back)

The fireplace (and 
firebox) must be made 
level and plumb during 
installation.  Use shims 
under the fireplace to 
properly level the 
fireplace.  

Zero 

Clearance 

Can

Firebox

WARNING:
Failure to correctly level and plumb 
this fireplace will lead to doors that 
swing open or closed.

AAA

AAA

AAA

AAA

AAA

AAA

AAA

Figure 10

 

Fireplace  must  be  placed  directly  on  wood  or  non-combustible  surface  (not  on  linoleum  or
carpet)

 

Fireplace  must  be  installed  on  a  level  surface  capable  of  supporting  the  fireplace  and  chimney

 

Place  the  ember  strip  included  with  the  fireplace  below  the  front  edge  of  the  fireplace  (see
Figure  11).

Place this ember 
strip under the front 
of the fireplace and 
the back edge of the 
hearth.

NOTE: On the 36 Elite,  
the ember strip will 
need to be shortened.

The ember strip 
insures no ember falls 
between the fireplace 
and hearth onto the 
combustible floor.

EMBER STRIP
INSTRUCTIONS

Figure 11

Содержание 44-Elite

Страница 1: ...A AA AA AA AAA AAA AAA AAA AAA AAA AAA AAA 44 Elite Installation Manual 4800 Harbour Pointe Blvd SW Mukilteo WA 98275 Wood Burning Zero Clearance Fireplace 2007 Travis Industries 10 00 93508093 Tested...

Страница 2: ...wood heater in a manner inconsistent with operating instructions in the owner s manual or if the catalytic element is deactivated or removed Do not use a fireplace insert or other products not specif...

Страница 3: ...ireplace Placement 11 Clearances 12 Raised Fireplaces 12 Cooling Vent Requirements 13 Blower Requirements 14 Blower Duct Routing 14 Blower Duct Connection 15 Blower Electrical Connection 15 Chimney Re...

Страница 4: ...d Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney...

Страница 5: ...700 Heating capacity will vary with floor plan insulation and outside temperature Dimensions 8 Blower Lead 8 Electrical Input Lead 6 1 2 46 26 1 8 49 24 31 1 2 Includes the 1 2 stand offs 44 The set u...

Страница 6: ...or Blower Two 10 Flex Ducts 7 Diameter For Cooling Vents Two Vent Hoods For Cooling Vents Two Vent Hood Storm Collars For Cooling Vents Faceplate Gasket Items Shipped with the Faceplate Faceplate two...

Страница 7: ...the section Minimum Clearances See the section Chimney Requirements See the section Hearth Requirements See the section Blower Requirements See the section Cooling Vent Requirements See the section Mi...

Страница 8: ...A A A A AAAAAAAAAAAAAAAAAA AAAAA AA AA AA AA AA Fireplace Interior of Home Internal Blower Exterior Wall Exterior Figure 5 Cooling Air P Trap When installing the cold air ducts make sure to include a...

Страница 9: ...ir can be heated by the house causing syphoning This pulls cool air through the cooling channel leading to fireplace cooling Cooling air is required by the fireplace to prevent overheating Negative pr...

Страница 10: ...pe to header clearance A firestop is required at the top of the fireplace enclosure or ceiling level whichever is lower Min 4 1 2 NOTE make sure the enclosure is wide enough to accommodate the blower...

Страница 11: ...so located on back The fireplace and firebox must be made level and plumb during installation Use shims under the fireplace to properly level the fireplace Zero Clearance Can Firebox WARNING Failure t...

Страница 12: ...y from high traffic areas Fireplace must be placed so the vents below and above the glass do not become blocked Raised Fireplaces If the fireplace is raised the fireplace enclosure must be raised as w...

Страница 13: ...0 0 and 1 25 Included with the fireplace are two 12 lengths of vent use a connector and seal if adding more length The duct terminations must be located so they can not be blocked e g snow drifts Incl...

Страница 14: ...ower duct is 15 use the included duct start collar The maximum length for 8 diameter blower duct is 25 use two 6 to 8 adapters NOTE The shorter the blower duct the greater the air flow A maximum of tw...

Страница 15: ...how the homeowner the blower location and inform them of the need to clean periodically Remove the four screws that go into these holes Shake the filter to remove any dirt that may have accumulated In...

Страница 16: ...pipes If the outer pipe does not line up with the brackets remove the brackets and re attach them to the top of the fireplace Connect the inner pipe to the inner liner with three sheet metal screws Fi...

Страница 17: ...ght above the specified minimum may be necessary to reduce wind induced down drafting and back puffing or to increase draft thereby improving fireplace operating characteristics Chimney must be totall...

Страница 18: ...walls The table below details the amount of offset X and rise R gained from various chimney lengths when used with 30 elbows see Figure 21 Make sure to add the amounts for both elbows Two sections may...

Страница 19: ...bove the fireplace before the chimney penetrates the ceiling use a firestop the chimney must maintain the clearances listed below 5 to the rear of the chimney 4 1 2 to the front of the chimney Min Cle...

Страница 20: ...a sloped roof it is important to determine the size of the framing for clearance purposes Use the appropriate column for 2 x 4 or 2 x 6 rafters It is not necessary to frame around the hole opening if...

Страница 21: ...se is above the roof structure The chimney cap must still maintain the 2 3 10 clearance to any other structure See the illustration below Chimneys extending beyond a certain height frequently 5 above...

Страница 22: ...quires 1 2 thick concrete board or other non combustible to extend from the header to the base of the fireplace and to the framing members on both sides do not use sheetrock or drywall See Figure 27 T...

Страница 23: ...et the mantel requirements listed in this manual To achieve a facing that is flush with the drywall to the side of the fireplace recess the framing directly next to the fireplace see Figure 28 1 2 Dry...

Страница 24: ...above the base See Figure 29 The mantel must not extend more than 8 1 2 in front of the faceplate Mantel side columns that extend more than 3 4 beyond the faceplate must maintain an 18 clearance to t...

Страница 25: ...rth material can go above this point Fireplace Faceplate Ember Strip 6 1 2 Max 18 Min Check Local Building Codes AA AA AA AAAAAAAAA AAAAAAAAA A A A A AAAAAAAAA AAAAAAAAA AA AA AA Minimum 1 cement boar...

Страница 26: ...raps in the fireplace Treated wood breaks down the catalyst inside the fireplace decreasing efficiency and increasing emissions Remove Set Up Face Remove the set up face using a phillips screwdriver s...

Страница 27: ...8 allen wrench Install the baffle and grate AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA A A A A A AAAA AAAA AAAA...

Страница 28: ...h the gasket onto the back of the face note how the holes on the gasket line up with the holes on the face The 36 is pictured the 44 installs in a similar fashion Attach the side gaskets in the same f...

Страница 29: ...h the faceplate see Figure 34 NOTE do not pinch any of the wires in the lower right between the faceplate and the fireplace AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA A...

Страница 30: ...ick connects from the switch plate to the two female quick connects leading from the fireplace These male quick connects are for the summer fan switch connect them together to test if the blower opera...

Страница 31: ...it between the door gasket and the fireplace Adjustments are made to the door latch by moving the washers from either side of the door latch and tightening the inner nut against the outer nut The door...

Страница 32: ...ent Requirements 10 Fireplace Placement 11 Firestops 20 Framing Dimensions at 45 10 Framing the Roof 20 Hearth Requirements 25 Heating Specifications 6 Install the Faceplate Insulation 28 Installation...

Отзывы: