Installation
(for qualified installers only)
17
© Travis Industries
4050714
93508093
Chimney Height
•
Minimum 15'
system height
(measured from the
base of the
fireplace)
•
Maximum 35'
system height
(measured from the
base of the
fireplace)
NOTE
: In some
problematic situations,
additional chimney
height above the
specified minimum
may be necessary to
reduce wind-induced
down drafting and back
puffing, or to increase
draft, thereby improving
fireplace operating
characteristics.
Chimney must be totally
enclosed when passing
through living space with a
minimum 2" clearance to
combustibles.
3' Min.
2' Min.
10'
System Height
35' Max.
15' Min.
2" Min. Air
Space to
Combustibles
Rain Cap
Storm Collar
Flashing
Firestop Between Floor Levels
Attic Firestop (with insulation shield)
Cooling
Vent
Figure 20